REELING CABLES - UTVCAVI
UTVFLEX CABLES FOR reeling application festoon application mining application tunnelling application steel mills sea ports infrastructure marine application
UTVFLEX CABLES FOR
reeling application
festoon application
mining application
tunnelling application
steel mills
sea ports
infrastructure
marine application
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
UTVFLEX ® - PUR HF
®
UTVFLEX ® - PUR HF
Based on DIN VDE 0250 Part 814
Flexible cable designed for power and signalling mobile connections,
under severe mechanical stresses (tensile strength and torsion),
for heavy duty conditions, abrasion and crushing. The cable is typically
used in cable winding reels for harbour cranes, container cranes,
con- veyors, handling machines and mining and tunnelling equipment.
The halogen free polyurethane sheath grants more lightness by retaining
the mechanical properties and abrasion resistance.
5
1
3
2
4
1 PHASE CONDUCTORS
MATERIAL: tinned copper
CONSTRUCTION: class 5 VDE 0295 (IEC 60228)
2 INSULATION
MATERIAL: special compound, according to VDE 0207 Part 20
CORES IDENTIFICATION
According to DIN VDE 0293 Part 308 (HD 308 S2)
LAYING-UP
≤ 8 times the laying-up cores diameter
3 INNER SHEATH
MATERIAL: halogen free polyurethane
4 ANTITWISTING ELEMENT
MATERIAL: polyester braid between inner and outer sheath
5 OUTER SHEATH
MATERIAL: halogen free polyurethane
COLOUR: standard black, cores white with printed numbers
4
5
1
2
3
ELECTRICAL WORKING DATA
Nominal rated voltage U 0 / U kV 0,6/1
Test voltage kV 4
Max AC voltage kV 0,7/1,2
Max DC voltage kV 1,8
Current rating A According to VDE 0298 Part 4
THERMAL WORKING DATA
Maximum short circuit temperature °C 250
Maximum working temp. on the conductor °C 90
Minimum ambient temperature °C
Mobile condition: – 40
Static condition: – 50
MECHANICAL WORKING DATA
Bending radius mm According to VDE 0298 Part 3
Maximum torsional stress °/m ± 25
Maximum tensile load* N/mm 2 30
Max working speed m/min 180
Special test
Reeling test
* Referred to the total phase conductors cross section
CHEMICAL WORKING DATA
Oil resistance According to IEC 60811-404
Ozone resistance According to IEC 60811-403
Burning behaviour According to IEC 60332-1-2
Gas emission during combustion According to IEC 60754-1
APPLICATION
26 27
www.utvcavi.com
www.utvcavi.com