Connecting to a Data Converter, Combiner, or Splitter

IMPORTANT: To connect to a PC it is necessary to install a Data Converter or

Combiner. Follow the installation instructions that are supplied with the unit.

Connecting to an NMEA 0183 Display

Cable Routing

Route the WeatherStation cable to the display. Do not fasten the cable in place at

this time.

Heater model with cable run greater than 20m (60')—Route the WeatherStation

cable to a junction box (Figure 6). Route a separate cable from the junction box to

the NMEA display. Route red and black 14AWG wires from the junction box to a

24VDC power supply. Do not fasten the cables and wires in place at this time.

junction box

WeatherStation

Instrument

1 1

2

2

3 3

4 4

5 5

6 6

red wire

(14AWG)

black wire

(14AWG)

power

supply

(24VDC)

7 7

8 8

9

9

33-1167-01

[10m (30')]

06-228

NMEA 0183

display

Figure 6. Wiring the junction box (not to scale)

Copyright © 2016 Airmar Technology Corp.

Wire the junction box using the wiring diagram below (Figure 7) To prepare the

cables, follow “Preparing the Wires”.

Figure 7. Heater models with a cable run greater than 20m (60')

Copyright © 2016 Airmar Technology Corp.