Connecting to a Data Converter, Combiner, or Splitter
IMPORTANT: To connect to a PC it is necessary to install a Data Converter or
Combiner. Follow the installation instructions that are supplied with the unit.
Connecting to an NMEA 0183 Display
Cable Routing
Route the WeatherStation cable to the display. Do not fasten the cable in place at
this time.
Heater model with cable run greater than 20m (60')—Route the WeatherStation
cable to a junction box (Figure 6). Route a separate cable from the junction box to
the NMEA display. Route red and black 14AWG wires from the junction box to a
24VDC power supply. Do not fasten the cables and wires in place at this time.
junction box
WeatherStation
Instrument
1 1
2
2
3 3
4 4
5 5
6 6
red wire
(14AWG)
black wire
(14AWG)
power
supply
(24VDC)
7 7
8 8
9
9
33-1167-01
[10m (30')]
06-228
NMEA 0183
display
Figure 6. Wiring the junction box (not to scale)
Copyright © 2016 Airmar Technology Corp.
Wire the junction box using the wiring diagram below (Figure 7) To prepare the
cables, follow “Preparing the Wires”.
Figure 7. Heater models with a cable run greater than 20m (60')
Copyright © 2016 Airmar Technology Corp.