U n d e r s t a n d i n g t h e s p e c i f i c a t i o n s<br />

Uniform Load: A load is applied over a 1m x 1m area with<br />

the deflection of the panel not exceeding 2.5mm for the<br />

uniform load specified.<br />

Rolling Load: A load rolled back and forth across<br />

the panel which is applied through 3 different size<br />

wheels. Deflection is measured after 10, 10,000 and<br />

40,000 continuous cycles.<br />

U n d e r s t a n d i n g t h e s p e c i f i c a t i o n s<br />

Impact Load: A weight is dropped from 900mm onto<br />

a 25mm x 25mm steel indentor without the system<br />

collapsing.<br />

Pedestal Axial and Horizontal Load: This is 2 tests,<br />

a load is applied vertically onto the pedestal and<br />

also horizontally. The pedestal should not show any<br />

permanent deformation after each test.