<strong>AWWA</strong> <strong>C905</strong>-<strong>10</strong>: <strong>PVC</strong> <strong>Pipe</strong> <strong>for</strong> <strong>Sewer</strong> <strong>Applications</strong><br />

NOMINAL<br />

PIPE SIZE<br />

OUTSIDE<br />

DIA. – NOM.<br />

(OD)<br />

*APPROX.<br />

BELL DIA.<br />

(BD)<br />

**APPROX.<br />

BELL DEPTH<br />

(C)<br />

INSERT<br />

MARK<br />

(L)<br />

14” 15.3 18.75 9.00 8.00<br />

16” 17.4 21.00 <strong>10</strong>.00 9.00<br />

18” 19.5 23.50 <strong>10</strong>.38 9.38<br />

20” 21.6 26.25 11.00 <strong>10</strong>.00<br />

24” 25.8 31.25 13.00 12.00<br />

30” 32.0 37.25 15.13 14.13<br />

36” 38.3 43.30 19.13 18.13<br />

NOMINAL PIPE<br />

SIZE<br />

PR 80<br />

DR 51<br />

(T)<br />

PR <strong>10</strong>0<br />

DR 41<br />

(T)<br />

PR 125<br />

DR 32.5<br />

(T)<br />

PR 165<br />

DR 25<br />

(T)<br />

PR 200<br />

DR 21<br />

(T)<br />

PR 235<br />

DR 18<br />

(T)<br />

PR 305<br />

DR 14<br />

(T)<br />

14” .612 .729 .850 1.093<br />

16” .424 .535 .696 .829 .967 1.143<br />

18” .476 .780 .929 1.083<br />

20” .527 .864 1.029 1.200<br />

24” .629 .794 1.032 1.229 1.433<br />

30” .627 .780 .985 1.280 1.524<br />

36” .751 .934 1.178 1.532 1.824<br />

Note: These dimensions are <strong>for</strong> estimating purposes only * Dimension given <strong>for</strong> Approx. Bell Diameter (BD) is <strong>for</strong> highest pressure class<br />

** Nominal depth, depth will vary by pressure class