Biometrics Ltd
Biometrics Ltd
Biometrics Ltd
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Biometrics</strong> <strong>Ltd</strong> offers a technologically advanced yet cost effective range of EMG display & data capture<br />
systems offering both fully portable and real time display & analysis options.<br />
The SX230 Active EMG Sensor<br />
The SX230 is a pre amplifier designed and<br />
manufactured by <strong>Biometrics</strong> and has been<br />
developed with ease of use and superb<br />
quality of signal in mind. Unique to the<br />
design is the Input Impedance of<br />
10,000,000 M Ohms. What this means<br />
in practise is that little or no skin<br />
preparation and no gels or creams are<br />
required, yet the quality of the signal<br />
recorded is absolutely superb for both<br />
static and dynamic applications.<br />
Simply apply the electrodes over the body of<br />
the small or large muscles being measured<br />
using the die cut medical grade double sided<br />
adhesive tape (part no. T350).<br />
Independent of the number of active EMG<br />
sensors being used at any one time only one<br />
ground reference cable is required.<br />
The ground reference cable R200 comes<br />
complete with a convenient elastic wrist band<br />
for ease of use.<br />
The ground reference cable R300 comes with<br />
a standard 2 mm spring plug for connection<br />
to proprietary disposable electrodes with a 2<br />
mm spring socket<br />
Taking EMG measurements<br />
The SX230 may readily connect to either the<br />
DataLINK or DataLOG. Both these instruments<br />
are general purpose data collection devices and<br />
may collect signals from a wide range of<br />
sensors simultaneously with the EMG. This is<br />
ideal for correlation of muscle activity with other<br />
physiological parameters.<br />
Graphs showing extensor EMG and 3<br />
repetitions of maximum grip strength of a<br />
normal subject. Note this trace is raw data and<br />
NO filtering has been applied to reduce<br />
artefacts. Data collected using DataLINK,<br />
active EMG sensor SX230 and hand<br />
dynamometer G100.<br />
SPECIFICATION Part no. SX230<br />
Electrodes integral dry reusable<br />
Gain x1000<br />
Bandwidth 20 Hz – 450 Hz<br />
Noise < 5µV<br />
Input Impedance > 10,000,000 M Ohms<br />
Supply Voltage +4.5 to 5.0 Vdc<br />
CMRR @ 60 Hz (dB) > 96 dB (typically 110 dB)<br />
Cable highly flexible grade, length 1.25 m<br />
(custom lengths on request)<br />
Plug direct connection to DataLINK or<br />
DataLOG (custom lengths on request)<br />
Mass 12 g (excluding cable and connector)<br />
Electrostatic Discharge Circuit protected<br />
Ground Reference Part no. R200<br />
Type reusable<br />
Cable highly flexible grade, length 1.25 m<br />
(custom lengths on request)<br />
Application wrist strap or user preference<br />
Ground Reference Part no. R300<br />
Type reusable<br />
Cable highly flexible grade, length 1.25 m<br />
(custom lengths on request)<br />
Application connection to disposable<br />
electrodes using 2 mm spring plug<br />
Application Tape Part no. T350<br />
Double sided medical grade Die cut<br />
for ease of application.<br />
EMG & the DataLOG<br />
The DataLOG offers the user the ability to<br />
collect EMG and other data reliably from up<br />
to 8 channels simultaneously in a truly<br />
portable configuration. The capability offered<br />
the user of EMG measurements using the<br />
DataLOG is unrivalled even by much more<br />
costly systems.<br />
EMG & the DataLINK.<br />
The DataLINK provides the user the ability to<br />
collect EMG and other data simultaneously<br />
with real time display & real time analysis.<br />
The usefulness and simplicity of this accurate<br />
display & real time feedback is emphasized<br />
for both a research and educational setting.<br />
Graph Key<br />
The Graph Key window controls the<br />
traces that are to be displayed and<br />
the units to use on the Y-axis.<br />
Display & Analysis of the EMG data Analysis Software for<br />
DataLOG & DataLINK.<br />
Results Key<br />
The Results window displays<br />
information about the traces within<br />
the current active display window<br />
whether nor not they are currently<br />
visible.<br />
The NEW V3.0 <strong>Biometrics</strong> Analysis software is one of the most powerful<br />
yet cost effective EMG & general data display & analysis software tools<br />
available. The software is purposefully NOT sold in modules but as one<br />
complete package to give the user a complete product at a price what is<br />
below most basic entry packages of other commercial products.<br />
The NEW V3.0 <strong>Biometrics</strong> Analysis software comes with a<br />
comprehensive Help menu that may be used as a tutorial to use both<br />
the hardware and software for the first time.<br />
Summary of main features:<br />
• Transfer data to memory for display, analysis and saving.<br />
• Open an unlimited number of data files with the option to track the<br />
time axis across all files allowing display & analysis for a large<br />
number of channels.<br />
• Waveform display in multiple windows and formats with full zoom,<br />
scroll and area marking facilities, option to split, tile and cascade<br />
windows<br />
• Engineering units with custom scaling ability on all traces independently<br />
• Each recorded file is both time & date stamped<br />
• Independent upper and lower alarm levels both audible and visual.<br />
• File save, load and export facilities with many files simultaneously<br />
• Graphs may be pasted into other Window applications such as<br />
Microsoft Office.<br />
• Comprehensive filtering (see below)<br />
• Power Spectrum<br />
• X-Y graphs<br />
• Multiple traces per window<br />
• Unlimited number of windows<br />
• Markers – time and/or Y axis<br />
• Paste the graph & graph key to clipboard<br />
• Full trace management (change line width, color, background color etc.)<br />
• Export as ASCII or Wave file<br />
• Calculations:- minimum, maximum, mean, number of excursions,<br />
number of repetitions.<br />
• Filtering:<br />
~ rectify ~ scale<br />
~ average ~ medium<br />
~ RMS ~ mean<br />
~ velocity ~ integrate<br />
~ integrate ~ median frequency<br />
~ offset ~ mean frequency<br />
• Power Spectrum Graph (linear & logarithmic)<br />
• FFT high pass filters: remove DC, remove very low frequencies<br />
Settings<br />
The Settings window displays the<br />
settings used for the traces within<br />
the current active display window.<br />
The values relate to the analogue<br />
traces 1 to 8.<br />
• FFT window functions:<br />
~ Rectangle / Flat top ~ Blackmann Opt<br />
~ Triangle / Bartlett ~ Hamming<br />
~ Blackmann standard ~ Hann<br />
Display of right knee flexion / extension with raw unfiltered quadriceps<br />
and hamstring EMG activity of a normal subject.<br />
Power Spectrum<br />
Inputs<br />
If there is valid communications between the<br />
PC and a DataLINK or DataLOG unit, the<br />
Input Values window displays the current<br />
analogue and digital inputs in engineering<br />
units.<br />
EMG Systems<br />
The PS850 system is dedicated<br />
to EMG measurements and comes<br />
with DataLOG, Management &<br />
Analysis software, 8 active EMG<br />
sensors and event marker IS3.<br />
The PS900 Portable System<br />
comes with DataLOG, Management<br />
& Analysis Software, Angle Display<br />
Unit, 8 active EMG sensors, 8<br />
goniometers (choice of standard sizes to accommodate upper and<br />
lower extremity), 1 torsiometer, and event marker.<br />
The DS3000 Deluxe Data Acquisition System comprises DataLOG and<br />
DataLINK both with Management & Analysis software, 8 active EMG<br />
sensors, R200 earthing strap, T350 adhesive tape, 9 goniometers<br />
(choice of sizes), 1 torsiometer Q150, 2 event markers and the<br />
contact switch assembly FS4.