<strong>Biometrics</strong> <strong>Ltd</strong> offers a technologically advanced yet cost effective range of EMG display & data capture<br />

systems offering both fully portable and real time display & analysis options.<br />

The SX230 Active EMG Sensor<br />

The SX230 is a pre amplifier designed and<br />

manufactured by <strong>Biometrics</strong> and has been<br />

developed with ease of use and superb<br />

quality of signal in mind. Unique to the<br />

design is the Input Impedance of<br />

10,000,000 M Ohms. What this means<br />

in practise is that little or no skin<br />

preparation and no gels or creams are<br />

required, yet the quality of the signal<br />

recorded is absolutely superb for both<br />

static and dynamic applications.<br />

Simply apply the electrodes over the body of<br />

the small or large muscles being measured<br />

using the die cut medical grade double sided<br />

adhesive tape (part no. T350).<br />

Independent of the number of active EMG<br />

sensors being used at any one time only one<br />

ground reference cable is required.<br />

The ground reference cable R200 comes<br />

complete with a convenient elastic wrist band<br />

for ease of use.<br />

The ground reference cable R300 comes with<br />

a standard 2 mm spring plug for connection<br />

to proprietary disposable electrodes with a 2<br />

mm spring socket<br />

Taking EMG measurements<br />

The SX230 may readily connect to either the<br />

DataLINK or DataLOG. Both these instruments<br />

are general purpose data collection devices and<br />

may collect signals from a wide range of<br />

sensors simultaneously with the EMG. This is<br />

ideal for correlation of muscle activity with other<br />

physiological parameters.<br />

Graphs showing extensor EMG and 3<br />

repetitions of maximum grip strength of a<br />

normal subject. Note this trace is raw data and<br />

NO filtering has been applied to reduce<br />

artefacts. Data collected using DataLINK,<br />

active EMG sensor SX230 and hand<br />

dynamometer G100.<br />

SPECIFICATION Part no. SX230<br />

Electrodes integral dry reusable<br />

Gain x1000<br />

Bandwidth 20 Hz – 450 Hz<br />

Noise < 5µV<br />

Input Impedance > 10,000,000 M Ohms<br />

Supply Voltage +4.5 to 5.0 Vdc<br />

CMRR @ 60 Hz (dB) > 96 dB (typically 110 dB)<br />

Cable highly flexible grade, length 1.25 m<br />

(custom lengths on request)<br />

Plug direct connection to DataLINK or<br />

DataLOG (custom lengths on request)<br />

Mass 12 g (excluding cable and connector)<br />

Electrostatic Discharge Circuit protected<br />

Ground Reference Part no. R200<br />

Type reusable<br />

Cable highly flexible grade, length 1.25 m<br />

(custom lengths on request)<br />

Application wrist strap or user preference<br />

Ground Reference Part no. R300<br />

Type reusable<br />

Cable highly flexible grade, length 1.25 m<br />

(custom lengths on request)<br />

Application connection to disposable<br />

electrodes using 2 mm spring plug<br />

Application Tape Part no. T350<br />

Double sided medical grade Die cut<br />

for ease of application.<br />

EMG & the DataLOG<br />

The DataLOG offers the user the ability to<br />

collect EMG and other data reliably from up<br />

to 8 channels simultaneously in a truly<br />

portable configuration. The capability offered<br />

the user of EMG measurements using the<br />

DataLOG is unrivalled even by much more<br />

costly systems.<br />

EMG & the DataLINK.<br />

The DataLINK provides the user the ability to<br />

collect EMG and other data simultaneously<br />

with real time display & real time analysis.<br />

The usefulness and simplicity of this accurate<br />

display & real time feedback is emphasized<br />

for both a research and educational setting.<br />

Graph Key<br />

The Graph Key window controls the<br />

traces that are to be displayed and<br />

the units to use on the Y-axis.<br />

Display & Analysis of the EMG data Analysis Software for<br />

DataLOG & DataLINK.<br />

Results Key<br />

The Results window displays<br />

information about the traces within<br />

the current active display window<br />

whether nor not they are currently<br />

visible.<br />

The NEW V3.0 <strong>Biometrics</strong> Analysis software is one of the most powerful<br />

yet cost effective EMG & general data display & analysis software tools<br />

available. The software is purposefully NOT sold in modules but as one<br />

complete package to give the user a complete product at a price what is<br />

below most basic entry packages of other commercial products.<br />

The NEW V3.0 <strong>Biometrics</strong> Analysis software comes with a<br />

comprehensive Help menu that may be used as a tutorial to use both<br />

the hardware and software for the first time.<br />

Summary of main features:<br />

• Transfer data to memory for display, analysis and saving.<br />

• Open an unlimited number of data files with the option to track the<br />

time axis across all files allowing display & analysis for a large<br />

number of channels.<br />

• Waveform display in multiple windows and formats with full zoom,<br />

scroll and area marking facilities, option to split, tile and cascade<br />

windows<br />

• Engineering units with custom scaling ability on all traces independently<br />

• Each recorded file is both time & date stamped<br />

• Independent upper and lower alarm levels both audible and visual.<br />

• File save, load and export facilities with many files simultaneously<br />

• Graphs may be pasted into other Window applications such as<br />

Microsoft Office.<br />

• Comprehensive filtering (see below)<br />

• Power Spectrum<br />

• X-Y graphs<br />

• Multiple traces per window<br />

• Unlimited number of windows<br />

• Markers – time and/or Y axis<br />

• Paste the graph & graph key to clipboard<br />

• Full trace management (change line width, color, background color etc.)<br />

• Export as ASCII or Wave file<br />

• Calculations:- minimum, maximum, mean, number of excursions,<br />

number of repetitions.<br />

• Filtering:<br />

~ rectify ~ scale<br />

~ average ~ medium<br />

~ RMS ~ mean<br />

~ velocity ~ integrate<br />

~ integrate ~ median frequency<br />

~ offset ~ mean frequency<br />

• Power Spectrum Graph (linear & logarithmic)<br />

• FFT high pass filters: remove DC, remove very low frequencies<br />

Settings<br />

The Settings window displays the<br />

settings used for the traces within<br />

the current active display window.<br />

The values relate to the analogue<br />

traces 1 to 8.<br />

• FFT window functions:<br />

~ Rectangle / Flat top ~ Blackmann Opt<br />

~ Triangle / Bartlett ~ Hamming<br />

~ Blackmann standard ~ Hann<br />

Display of right knee flexion / extension with raw unfiltered quadriceps<br />

and hamstring EMG activity of a normal subject.<br />

Power Spectrum<br />

Inputs<br />

If there is valid communications between the<br />

PC and a DataLINK or DataLOG unit, the<br />

Input Values window displays the current<br />

analogue and digital inputs in engineering<br />

units.<br />

EMG Systems<br />

The PS850 system is dedicated<br />

to EMG measurements and comes<br />

with DataLOG, Management &<br />

Analysis software, 8 active EMG<br />

sensors and event marker IS3.<br />

The PS900 Portable System<br />

comes with DataLOG, Management<br />

& Analysis Software, Angle Display<br />

Unit, 8 active EMG sensors, 8<br />

goniometers (choice of standard sizes to accommodate upper and<br />

lower extremity), 1 torsiometer, and event marker.<br />

The DS3000 Deluxe Data Acquisition System comprises DataLOG and<br />

DataLINK both with Management & Analysis software, 8 active EMG<br />

sensors, R200 earthing strap, T350 adhesive tape, 9 goniometers<br />

(choice of sizes), 1 torsiometer Q150, 2 event markers and the<br />

contact switch assembly FS4.