06.01.2013 Views

MPS27C Military Air Data Test Set

MPS27C Military Air Data Test Set

MPS27C Military Air Data Test Set

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>MPS27C</strong> STANDARD SPECIFICATIONS<br />

Range Resolution Accuracy<br />

Parameter Measure Control Measure Control Measure Control<br />

Altitude(ft) from -3,000<br />

to 99,999<br />

from -3,000<br />

to +80,000<br />

Altitude slew Normal 0 to 6,000 0 to 6,000<br />

rate (ft/min) High Rate 0 to 99,999 0 to 50,000<br />

<strong>Air</strong>speed<br />

(kts)<br />

Normal 10 to 700 10 to 700<br />

High Rate 10 to 1000 10 to 1000<br />

Ultra Low Speed 5 to 200 5 to 200<br />

1ft same as<br />

measure<br />

25 > 1,000<br />

5 < 1,000<br />

1 < 50<br />

0.1 > 50<br />

0.1 > 20<br />

DMA-Aero Representative<br />

11 Old Sugar Hollow Road<br />

Danbury, CT 06812<br />

Tel: 203 790-8371<br />

Fax: 203 743-2051<br />

E-mail: sales@dma-aero.com<br />

www.dma-aero.com<br />

same as<br />

measure<br />

± 3 @ SL<br />

± 5 @ 30,000<br />

±20 @ 60,000<br />

±2<br />

±10 ±1% of reading same as<br />

measure<br />

0.1 ±0.5 @ 50<br />

±0.1 @ > 500<br />

ULS: ±0.001 inHg<br />

Mach No. 0 to 10 0 to 10 0.001 0.001 < 0.002 ±0.002<br />

<strong>Air</strong>speed slew rate (kt/min) 0 to 700 0 to 700 10 10 ±10 ±1% of reading ±5%<br />

Notes; Control capability on all load volumes: Static to 125cu ins (2L) Pitot to 80cu ins (1.3L). Volumes up to 1000 cu in (17L) are possible<br />

with reduced RoC.<br />

Standard <strong>Test</strong> Functions:<br />

• pressure/vacuum generation<br />

• automatic leak check<br />

• controlled venting to ambient<br />

• altitude/airspeed input<br />

• static/dynamic/total pressure input<br />

• altitude/ airspeed rates input<br />

• Mach Number input<br />

• EPR generation<br />

• TAS / IAS toggle<br />

• Offset correction<br />

• 30 user programmed test profiles<br />

• ultra low speed (5 to 200 kts) function<br />

• Compact Flash card to store test results<br />

• Audible indication when approaching set point<br />

Display and Keypad<br />

Integral display and keypad in splashproof<br />

and shock protected front panel.<br />

The back-lit 4x20 LCD shows all the test<br />

parameters simultaneously.<br />

Calibration<br />

One year interval, performed using software.<br />

Stability better than 50ppm/annum<br />

Temperature Range<br />

Operating -5 to +50°C<br />

Storage -20 to +70°C<br />

Extended range Available on request<br />

Physical<br />

Weight: 66 lbs. (30 kg.)<br />

Dimensions: L24.6”x W19.7”x H11.7”<br />

(625x500x300mm)<br />

Environmental<br />

Splashproof and shockproof<br />

CE compliant.<br />

Power Supply<br />

Universal power supply: 90-240 VAC; 50-400 Hz. 90VA<br />

4 hours operation internal rechargeable battery<br />

±1<br />

Self <strong>Test</strong>.<br />

Automatic electrical and pneumatic test routines.<br />

Warranty<br />

MPS27 <strong>Test</strong>er 24 Months<br />

Internal Pumps 5000 operating hours<br />

OPTIONS<br />

A. 28 V d.c. Power supply: Provides extended range<br />

from 18 to 30 V d.c.<br />

B. ARINC429 interface<br />

C. IEEE488 GPIB control (RS232 standard)<br />

D. PDA for wireless remote control<br />

E. Multiple Isolators: Optional configuration to isolate<br />

with the keypad up to four static and up to four pitot<br />

lines via extra front panel connectors<br />

F. ADWIN PC Control software<br />

G. Hand held remote control unit: 4 x 20 characters<br />

backlit LCD with 50 ft extension cable<br />

H. Gray Code Altitude Device Readout<br />

I. HR <strong>Military</strong> Version (850 knots, 2 pumps)<br />

J. HR <strong>Military</strong> Version (1000 knots, 2 pumps)<br />

L. Extended temperature: Internal heating of valves, etc.<br />

for operation to -40°C<br />

- Pitot resonant sensor: as alternative<br />

- Custom Pitot/Static connections available<br />

Note: --- Specifications subject to change without notice<br />