<strong>Standard</strong> <strong>Features</strong><br />

� DC-RET Digital Control<br />

� Battery cables<br />

� Battery charger, factory-installed, 6 amps/120VAC<br />

� Critical silencer<br />

� EPA-certified fuel system<br />

� Field-connection terminal block<br />

� Fuel solenoid valve and secondary regulator<br />

� Multi-fuel system, LP vapor/natural gas, field-convertible<br />

� Braided stainless steel flexible fuel line<br />

� Oil drain extension with shutoff valve<br />

� Polymer base<br />

� Rodent-proof construction<br />

� Sound-deadening, flame-retardant foam per UL 94,<br />

class HF-1<br />

� Sound enclosure, quiet 68 dB(A) operation<br />

� 200-amp Model RDT automatic transfer switch<br />

� 5-year limited warranty<br />

� 70-amp line circuit breaker<br />

Available Accessories<br />

Electrical System<br />

� Battery<br />

� Battery heater<br />

Maintenance<br />

� Maintenance kit (air and oil filters)<br />

� General maintenance literature kit<br />

� Overhaul literature kit<br />

� Production literature kit<br />

Starting Aids<br />

� Carburetor heater, 120 VAC (recommended for<br />

reliable starting at temperatures below 0�C [32�F])<br />

Dimensions and Weights<br />

DISTRIBUTED BY:<br />

© 2007 by <strong>Kohler</strong> Co. All rights reserved.<br />

G4-121 (<strong>17RESL</strong>) 11/07<br />

KOHLER CO., <strong>Kohler</strong>, Wisconsin 53044 USA<br />

Phone 920-565-3381, Fax 920-459-1646<br />

For the nearest sales and service outlet in the<br />

US and Canada, phone 1-800-544-2444<br />

<strong>Kohler</strong>Power.com<br />

Model RDT Automatic Transfer Switch<br />

� 200 Amps, 240 VAC, 60 Hz<br />

� 2 pole, single phase<br />

� Withstand short circuit rating 22,000 amps with specified<br />

breakers<br />

� NEMA Type 3R enclosure<br />

� UL 1008 listed<br />

� Microprocessor-based transfer switch controls with fixed time<br />

delays<br />

� Automatic engine start<br />

� Engine cooldown (5 minutes)<br />

� Weekly exercise function (20 minutes), loaded or unloaded<br />

� Load control contact allows delayed connection of selected<br />

loads to the generator set (5 minutes)<br />

� LED indicator shows:<br />

� Exercise running<br />

� Faults<br />

� Dimensions, H x W x D:<br />

613 x 340 x 177 mm (24.1 x 13.4 x 7.0 in.)<br />

� Weight: 15 kg (33 lb.)<br />

Overall Size, L x W x H: 1199 x 713 x 803 mm<br />

(47.2 x 28.1 x 31.6 in.)<br />

Weight: 227 kg (500 lb.)<br />

Shipping weight with ATS: 254 kg (560 lb.)<br />

H<br />

W L<br />

NOTE: This drawing is provided for reference only and should not be used for planning<br />

installation. Contact your local distributor for more detailed information.