Nominal efficiency (%)<br />
100<br />
95<br />
90<br />
85<br />
80<br />
75<br />
70<br />
IEC 60034-30:20<strong>08</strong><br />
<strong>Electric</strong> motors efficiency classes (4-pole 50 Hz)<br />
0,1 1 10 100 1000<br />
<strong>Motor</strong> output in log scale (kW)<br />
2. Global projects:<br />
After two years of SEEEM (www.seeem.org) we have now a more permanent and global platform: the<br />
new <strong>IEA</strong> Implementing Agreement on Efficient <strong>Electric</strong>al End-Use Equipment <strong>4E</strong> <strong>Electric</strong> <strong>Motor</strong> <strong>Systems</strong><br />
<strong>Annex</strong> (www.motorsystems.org). The work starts now with 7 participating countries in 6 tasks:<br />
Tasks Countries Australia<br />
A Implementation Support & Outreach<br />
B Technical Guide for <strong>Motor</strong> <strong>Systems</strong><br />
C Testing Centers<br />
E Training & Capacity Building<br />
F Energy Management in Industry<br />
G New <strong>Motor</strong> Technologies<br />
H Total <strong>Motor</strong> <strong>Systems</strong> Integration<br />
Austria<br />
Denmark<br />
Japan<br />
- 6 -<br />
South Africa<br />
* *<br />
Switzerland<br />
IE3<br />
IE2<br />
IE1<br />
UK<br />
Task Leader<br />
Participant<br />
3. Legislation and regulation:<br />
The view that only mandatory standards can move markets more rapidly has been shown in the USA,<br />
Canada, Australia and New Zealand. Now the European Ecodesign Energy-using Products Directive<br />
will produce Minimum Energy performance Standards in 2009 for motors, pumps and fans<br />
(www.ecomotors.org).<br />
4. More Efficient products:<br />
Premium Efficiency motors IE3 are being sold in the market place with 60 Hz and 50 Hz, now available<br />
in sizes from 0.75 kW to 375 kW. NEMA frame sizes and 60 Hz made this possible a while ago, European<br />
frame sizes (EN 50347) and 50 Hz make it more difficult but possible.<br />
Where do we go from here?<br />
In the next two days we try to bring together some 120 motor producers and users, experts and administrators<br />
from 20 countries around the globe to improve and share their knowledge on efficiency<br />
technology and policy. This Global <strong>Motor</strong> Network should expand within <strong>4E</strong> and contribute to harvest<br />
the energy efficiency potential in this field.<br />
The SEEEM project that has started the harmonization drive in 2006 will now become history. The <strong>4E</strong><br />
<strong>Motor</strong> <strong>Systems</strong> program will take over in a more sustainable structure.<br />
And: We will gather again at EEMODS’09 on 14-17 September 2009 in Nantes France to continue this<br />
global drive for more efficient motor systems.<br />
Thanks<br />
We want to thank to all supporters of SEEEM since its start in 2006 and to all the speakers, sponsors<br />
and participants in this years Side Event and in the 2 -day MS’<strong>08</strong> conference for their active contribution.