4-1-29 FI SYSTEM DIAGNOSIS<br />

“C22” OXYGEN SENSOR CIRCUIT MALFUNCTION<br />

DETECTED CONDITION<br />

Oxygen sensor signal is not input in ECU since then<br />

more than 180 sec. after the engine run.<br />

▣ INSPECTION<br />

1) Remove the seat.<br />

2) Turn the ignition switch “OFF” position.<br />

3) Check the Oxygen sensor coupler for loose or<br />

poor contacts.<br />

Is OK?<br />

YES<br />

NO<br />

● B or GR wire open or shorted to<br />

ground, or poor ⑨ or 59 connection.<br />

(Sensor)<br />

● OB or B wire open or shorted to<br />

ground, or poor � or 44 connention.<br />

(Heater)<br />

● If wire and connection are OK,<br />

intermittent trouble or faulty ECU.<br />

● Recheck each terminal and wire<br />

harness for open circuit and poor<br />

connection.<br />

Replace the Oxygen sensor.<br />

40<br />

POSSIBLE CAUSE<br />

● Oxygen sensor, Oxygen sensor heater circuit open<br />

or short.<br />

● Oxygen sensor, Oxygen sensor heater malfunction.<br />

● ECU malfunction.<br />

59<br />

44<br />

ECU Coupler<br />

�<br />