Industrial Automation Products - Ankit Electricals Ltd
Industrial Automation Products - Ankit Electricals Ltd
Industrial Automation Products - Ankit Electricals Ltd
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
3. TeSys D Bus Bar<br />
Ready to use Adaptor plates along with comb shaped Bus bar<br />
55<br />
LAD311 GV1G09 LAD311<br />
GV2G445<br />
GV2G254<br />
GV1G10<br />
GV2AF4<br />
MPCB<br />
Contactor<br />
4. TeSys AK5 pre-assembled busbar system<br />
AK5JB143<br />
AK5PA231<br />
AK5PA232<br />
NEW<br />
AK5PC33<br />
MPCB<br />
MPCB<br />
Contactor<br />
LA9Z40132<br />
MPCB<br />
GV2AF3<br />
• Ready made assemblies for Contactor and MPCB<br />
with ready to use adaptors and bus bars enables<br />
more number of starter assemblies in simple way�<br />
• Contactor and MPCB can be fixed on adaptor<br />
which can be further mounted on Din Rail� Inter<br />
Connection link between contactor and MPCB is<br />
also readily available to make power connections�<br />
• Busbar are used to distribute input power supply to<br />
all starters�<br />
Benefits:<br />
• With such assemblies, Standardization of the<br />
starter components can be done�<br />
• Optimum use of panel space can be achieved�<br />
• Considerable saving in installation time as the<br />
assembly is almost wire less�<br />
• Supply wires required to be plugged in the bus bar<br />
terminals<br />
Description Reference MRP<br />
Adaptor Plate LAD311 On Request<br />
Terminal Block GV1G09 On Request<br />
3 - pole bus bar 4 tap-offs GV2G445 On Request<br />
3 - pole bus bar 2 tap-offs GV2G254 On Request<br />
Protective Cover GV1G10 On Request<br />
Combination Block GV2AF4 On Request<br />
NEW<br />
• The assembly of automated control and distribution<br />
panels requires the use of <strong>Products</strong> those are not<br />
only safe but also simple and quick to mount and<br />
cable�<br />
• The AK5 pre-assembled busbar system meets all<br />
these criteria by incorporating adopters which can<br />
be mounted directly on busbars for Current<br />
distribution� Contactors and MPCB / OLR can be<br />
fixed on this adopter to save space and reduce<br />
wiring�<br />
Benefits:<br />
• Space saving<br />
• Saving of wiring and installation time�<br />
Description Reference MRP<br />
Bus bar 12 Taps AK5JB143 On Request<br />
Power socket 3 Phase<br />
32 Amps<br />
AK5PC33 On Request<br />
Double component Mounting<br />
Plate 25 Amps<br />
AK5PA232 On Request<br />
Single component Mounting<br />
Plate 25 Amps<br />
AK5PA231 On Request<br />
Description Reference MRP<br />
Adaptor for Bus bar – 32 Amps LA9Z40132 On Request<br />
Contactor reversing Combination