22<br />

<strong>Novoferm</strong> M ®<br />

<strong>Novoferm</strong> M ®<br />

Mounting behind the opening<br />

Width <strong>and</strong> height of frame<br />

Max. clear finished size<br />

Front view with mounting Block frame<br />

Without structural rebate<br />

Mounting behind the opening Mounting in the opening<br />

▲<br />

50 50<br />

Structural reveal size<br />

Width <strong>and</strong> height of frame<br />

Clear finished size + 25<br />

Co-ord. size<br />

Clear finished size<br />

30<br />

Min. clear finished size<br />

▲<br />

Mounting behind the opening Mounting in the opening<br />

OFF<br />

OFR<br />

Only apply floor pavement after mounting.<br />

Technical Information<br />

▲<br />

min. 20<br />

Co-ord. height + 30<br />

OFF<br />

Co-ord. size<br />

▲<br />

Co-ord. height – 180<br />

There must be a free space of<br />

35 mm above the top of the<br />

frame when using the <strong>door</strong><br />

operator models 403, 553 <strong>and</strong><br />

803.<br />

BR: Co-ord. size<br />

RAM: Width <strong>and</strong> height of<br />

frame<br />

OFF: Above finished floor<br />

OFR: Above crude floor<br />

Mounting in the opening<br />

Clear finished size<br />

Width <strong>and</strong> height of frame<br />

10<br />

Co-ord. size<br />

30<br />

10<br />

Co-ord. height + 30<br />

OFF<br />

78<br />

Co-ord. height – 180<br />

82