g-SSC : The Process<br />

The basis for g-SSC is advanced control algorithms and advanced<br />

slug recognition algorithms.<br />

The selection of the optimum configuration, operating mode,<br />

algorithms and the setup, configuration and testing of the controller<br />

is system specific. To ensure optimal performance it is important to<br />

note that the g-SSC is part of a complete service. Coupling the<br />

subsea, multi-phase hydraulics with the topsides control system<br />

must be achieved prior to establishing optimum design of the system.<br />

The <strong>Genesis</strong> g-SSC service is summarised below.<br />

1<br />

Data<br />

Collection<br />

2<br />

Modelling &<br />

Verification<br />

3<br />

Offline <strong>Controller</strong><br />

Configuration<br />

4<br />

Installation &<br />

Commissioning<br />

5<br />

Operating<br />

Support<br />

g-SSC : Applications<br />

Although we recognise that every system is different, we have tested<br />

the g-SSC on a number of applications. These include:<br />

Single well, single riser systems<br />

Multiple flowline, multiple riser systems<br />

Vertical risers<br />

Catenary riser<br />

Deepwater (tested to 1500m)<br />

g-SSC : <strong>Controller</strong> Details<br />

Adaptive Control<br />

The controller is designed to operate across the entire operating<br />

envelope of the system; varying well line up, GOR and water cut. This<br />

is achieved by self tuning algorithms that are continuously monitoring<br />

the key parameters and manipulating the control system tuning<br />

configuration.<br />

Initialization Routine<br />

In addition to the standard automatic and manual operating modes,<br />

the system also has an initialization mode. This mode allows the<br />

controller to stabilise the system in a controlled manner, ensuring that<br />

the system operates in the most stable regime.<br />

Multiple Operating Modes<br />

g-SSC can be configured to operate using input data from different<br />

sources. For example, the controller has algorithms to prevent SRBS<br />

R<br />

using inputs from either: TESPAR , a multi phase meter or differential<br />

pressure. The controller can simply be configured to suit the clientís<br />

requirements and the available instrumentation.<br />

Auto-recover From Operational Trips<br />

The control algorithm has a ìrecovery modeî allowing automatic slug<br />

suppression. This might occur if the control of the valve is temporarily<br />

lost, (for example, after a topsides trip or confirmed fire and gas alert).<br />

Anti-trip Functionality<br />

The controller can be configured with rule based anti-trip logic. This<br />

logic is designed to prevent the system tripping and centres around<br />

rates of level and pressure increase in the separator, separator volume<br />

etc.<br />

Web Based Monitoring<br />

Due to the complexity and dynamics of slug suppression, <strong>Genesis</strong><br />

offer a web based monitoring system. This will allow the controller to<br />

be continually monitored remotely and any required changes can be<br />

immediately advised to offshore.<br />

Off-line configuration and Operator Training<br />

The g-SSC is configured for each riser using a combined subsea<br />

pipeline - topsides dynamic model, (Olga and Hysys.Dynamics). This<br />

dynamic simulation can also be used for off-site operator training prior<br />

to the installation of the g-SSC.<br />

For further information contact Colin Manson<br />

Tel: +44 (0)1224 201209, Fax: +44 (0)1224 201222, e-mail: colin.manson@genesisoilandgas.com