<strong>Optistat</strong>SXM2<br />

ELIUM<br />

low vibration helium bath cryostat,<br />

sample in exchange gas<br />

This high stability helium bath cryostat is ideal for low-vibration optical spectroscopy<br />

and nano-scale microscopy. It offers a low base temperature (1.6 K), low levels of<br />

vibration and fast sample change. The sample is cooled by a dynamic exchange gas<br />

fed from an integral liquid helium reservoir. Its small footprint is ideal in laboratory<br />

where space is limited. It doesn’t require any external dewar or transfer tube.<br />

•<br />

•<br />

•<br />

Wide temperature <strong>range</strong>:<br />

from 1.6 to 300 K<br />

Excellent control and stability of the<br />

sample temperature enabled using<br />

the dynamic exchange gas principle<br />

Low vibration design for applications<br />

requiring high levels of mechanical<br />

stability including Scanning Probe<br />

Microscopy (SPM), Near-field<br />

Scanning Optical Microscopy<br />

(NSNOM) and Atomic Force<br />

Microscopy (AFM). The large<br />

sample space (49 mm) enables<br />

the integration of probe heads<br />

specifications<br />

<strong>Optistat</strong> family<br />

•<br />

•<br />

•<br />

•<br />

Quick sample change in less<br />

than 5 minutes via top-loading<br />

sample probe<br />

Efficient cryogenic design provides<br />

the convenience of consistent low<br />

temperature operation over<br />

a working day<br />

Generous optical access (f/2.2)<br />

for the radial windows<br />

Versatile: wide <strong>range</strong> of sample<br />

holders/rods including liquid cuvette<br />

for liquid samples and simple/precise<br />

height adjust/rotate sample rod<br />

Temperature <strong>range</strong> 1.6 – 300 K<br />

Temperature stability ± 0.1 K (measured over 10 min period)<br />

Maximum sample space 49 mm diameter<br />

Sample change time (mins) 5<br />

Cool down from ambient to 4.2 K (mins) 25<br />

Liquid helium capacity 4 L<br />

Hold time at 4.2 K ≥ 10 hours<br />

•<br />

•<br />

No liquid nitrogen<br />

used to minimise<br />

vibration<br />

Compact design for use on<br />

optical tables<br />

Electrical measurements via<br />

10-pin electrical feed wire to heat<br />

exchanger and/or wired on coax<br />

connectors<br />

For more information please visit:<br />

www.oxinst.com/optistatsXM2