ses were performed using capillary GC for separati<strong>on</strong>, flame<br />

i<strong>on</strong>izati<strong>on</strong> for detecti<strong>on</strong> <strong>and</strong> peak area ratio determinati<strong>on</strong> with<br />

the internal st<strong>and</strong>ard using an electr<strong>on</strong>ic integrati<strong>on</strong> or data<br />

system. No result was removed for either TC <strong>and</strong> <strong>on</strong>ly 4 results<br />

were removed for the 3 loti<strong>on</strong>s analyzed after statistical<br />

evaluati<strong>on</strong> of all data sets. Method performance was excellent<br />

for the TC products <strong>and</strong> adequate for the loti<strong>on</strong> formulati<strong>on</strong>s<br />

in this study directed under the German PAC <strong>and</strong> presented at<br />

CIPAC by T. Werner (Bayer AG, ZF-ZAD, Postfach 100140,<br />

D-41538 Dormagen, Germany).<br />

Malathi<strong>on</strong> (Insecticide): One technical material (TC)<br />

(OK?), <strong>on</strong>e emulsifiable c<strong>on</strong>centrate (EC), 2 oil in water<br />

emulsi<strong>on</strong>s (EW), <strong>and</strong> <strong>on</strong>e dustable powder (DP) were analyzed<br />

by separati<strong>on</strong> <strong>on</strong> capillary GC, flame i<strong>on</strong>izati<strong>on</strong> detecti<strong>on</strong>,<br />

internal st<strong>and</strong>ard peak area ratios, with electr<strong>on</strong>ic integrator<br />

or data system integrati<strong>on</strong> of peak areas for<br />

quantitati<strong>on</strong>. Twenty-three laboratories representing 19 countries<br />

returned data sets. Statistical analysis identified <strong>on</strong>ly 2 results<br />

from <strong>on</strong>e laboratory that were removed as outliers.<br />

Method performance was satisfactory for all materials ana-<br />

GENERAL REFEREE REPORTS:JOURNAL OF AOAC INTERNATIONAL VOL. 86, NO. 1, 2003 257<br />

lyzed in this study directed by Elsa V. Sorensen (Cheminova<br />

A/S, PO Box 9, DK-7620 Lemvig, Denmark), who also presented<br />

the results at CIPAC.<br />

Tribenur<strong>on</strong>-methyl (Broadleaf Herbicide): No fewer than<br />

19 results remained for each material after outlier removal<br />

from statistical analysis of the data returned by 23 laboratories<br />

from 14 countries. Analysis of 2 technical materials (TC)<br />

(OK?), 2 dry flowables (DF), <strong>and</strong> 2 water dispersible granules<br />

(WG) was c<strong>on</strong>ducted using LC–reversed-phase chromatography<br />

with internal st<strong>and</strong>ard, detecti<strong>on</strong> at 254 nm <strong>and</strong> peak area<br />

determinati<strong>on</strong> with electr<strong>on</strong>ic integrati<strong>on</strong> or data system.<br />

Good method performance was found for all test samples analyzed<br />

in this study directed <strong>and</strong> presented by David E.<br />

Brennan (DuP<strong>on</strong>t Crop Protecti<strong>on</strong>, Stine-Haskill Research<br />

Center, PO Box 30, Newark, DE 19714-0030, USA).<br />

Recommendati<strong>on</strong>s<br />

N<strong>on</strong>e.