Committee on Pesticides and Disinfectant Formulations
Committee on Pesticides and Disinfectant Formulations
Committee on Pesticides and Disinfectant Formulations
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ses were performed using capillary GC for separati<strong>on</strong>, flame<br />
i<strong>on</strong>izati<strong>on</strong> for detecti<strong>on</strong> <strong>and</strong> peak area ratio determinati<strong>on</strong> with<br />
the internal st<strong>and</strong>ard using an electr<strong>on</strong>ic integrati<strong>on</strong> or data<br />
system. No result was removed for either TC <strong>and</strong> <strong>on</strong>ly 4 results<br />
were removed for the 3 loti<strong>on</strong>s analyzed after statistical<br />
evaluati<strong>on</strong> of all data sets. Method performance was excellent<br />
for the TC products <strong>and</strong> adequate for the loti<strong>on</strong> formulati<strong>on</strong>s<br />
in this study directed under the German PAC <strong>and</strong> presented at<br />
CIPAC by T. Werner (Bayer AG, ZF-ZAD, Postfach 100140,<br />
D-41538 Dormagen, Germany).<br />
Malathi<strong>on</strong> (Insecticide): One technical material (TC)<br />
(OK?), <strong>on</strong>e emulsifiable c<strong>on</strong>centrate (EC), 2 oil in water<br />
emulsi<strong>on</strong>s (EW), <strong>and</strong> <strong>on</strong>e dustable powder (DP) were analyzed<br />
by separati<strong>on</strong> <strong>on</strong> capillary GC, flame i<strong>on</strong>izati<strong>on</strong> detecti<strong>on</strong>,<br />
internal st<strong>and</strong>ard peak area ratios, with electr<strong>on</strong>ic integrator<br />
or data system integrati<strong>on</strong> of peak areas for<br />
quantitati<strong>on</strong>. Twenty-three laboratories representing 19 countries<br />
returned data sets. Statistical analysis identified <strong>on</strong>ly 2 results<br />
from <strong>on</strong>e laboratory that were removed as outliers.<br />
Method performance was satisfactory for all materials ana-<br />
GENERAL REFEREE REPORTS:JOURNAL OF AOAC INTERNATIONAL VOL. 86, NO. 1, 2003 257<br />
lyzed in this study directed by Elsa V. Sorensen (Cheminova<br />
A/S, PO Box 9, DK-7620 Lemvig, Denmark), who also presented<br />
the results at CIPAC.<br />
Tribenur<strong>on</strong>-methyl (Broadleaf Herbicide): No fewer than<br />
19 results remained for each material after outlier removal<br />
from statistical analysis of the data returned by 23 laboratories<br />
from 14 countries. Analysis of 2 technical materials (TC)<br />
(OK?), 2 dry flowables (DF), <strong>and</strong> 2 water dispersible granules<br />
(WG) was c<strong>on</strong>ducted using LC–reversed-phase chromatography<br />
with internal st<strong>and</strong>ard, detecti<strong>on</strong> at 254 nm <strong>and</strong> peak area<br />
determinati<strong>on</strong> with electr<strong>on</strong>ic integrati<strong>on</strong> or data system.<br />
Good method performance was found for all test samples analyzed<br />
in this study directed <strong>and</strong> presented by David E.<br />
Brennan (DuP<strong>on</strong>t Crop Protecti<strong>on</strong>, Stine-Haskill Research<br />
Center, PO Box 30, Newark, DE 19714-0030, USA).<br />
Recommendati<strong>on</strong>s<br />
N<strong>on</strong>e.