Range Summary<br />

Monobloc Specifications<br />

Dimensions mm (inches)<br />

Nominal C8 to C10 to<br />

Voltage 1.75Vpc 1.80Vpc Terminal Weight<br />

Model (V) @ 25°C (77°F) @ 20°C (68°F) Fastener 1 Length Width Height kg (lbs)<br />

SBS8 12 7 7 M4 F 138 (5.4) 86 (3.4) 101 (4.0) 2.7 (5.9)<br />

SBS15 12 14 14 M6 M 200 (7.9) 77 (3.0) 140 (5.5) 5.7 (12.5)<br />

SBS30 12 26 26 M6 M 250 (9.8) 97 (3.8) 156 (6.1) 9.5 (20.9)<br />

HB30 12 26 26 M6 M 2 250 (9.8) 97 (3.8) 156 (6.1) 9.6 (21.1)<br />

SBS40 12 38 38 M6 M 250 (9.8) 97 (3.8) 206 (8.1) 12.7 (28.0)<br />

SBS60 12 51 51 M6 M 220 (8.7) 121 (4.8) 260 (10.2) 18.5 (40.7)<br />

SBS110 6 116 115 M8 M 200 (7.9) 208 (8.2) 239 (9.4) 3 21.2 (46.6)<br />

SBS114 4 116 115 M8 M 200 (7.9) 208 (8.2) 239 (9.4) 3 15.7 (34.5)<br />

SBS130 6 133 132 M8 M 200 (7.9) 208 (8.2) 239 (9.4) 3 22.7 (49.9)<br />

SBS134 4 133 132 M8 M 200 (7.9) 208 (8.2) 239 (9.4) 3 26.8 (37.0)<br />

SBS300 2 307 310 M8 M 200 (7.9) 208 (8.2) 239 (9.4) 3 21.7 (47.7)<br />

SBS390 2 361 360 M8 M 200 (7.9) 208 (8.2) 239 (9.4) 3 23.2 (51.0)<br />

SBSJ13 12 12 12 M6 F 178 (7.0) 87 (3.4) 132 (5.2) 5.7 (12.6)<br />

SBSJ16 12 15 15 M6 F 186 (7.3) 79 (3.1) 171 (6.7) 6.7 (14.8)<br />

SBSJ30 12 26 26 M6 F 178 (7.0) 168 (6.6) 127 (5.0) 11.8 (26.0)<br />

SBSJ40 12 39 39 M6 F 201 (7.9) 171 (6.7) 173 (6.8) 17.4 (38.2)<br />

SBSJ70 12 64 64 M6 F 328 (12.9) 166 (6.5) 175 (6.9) 28.8 (63.4)<br />

SBSB8 4 12 31 31 M8 F 280 (11.0) 97 (3.8) 150 (5.9) 5 10.3 (22.7)<br />

SBSB10 4 12 34 34 M8 F 280 (11.0) 97 (3.8) 175 (6.9) 5 12.8 (28.2)<br />

SBSB14 4 12 62 62 M8 F 280 (11.0) 97 (3.8) 256 (10.1) 5 19.1 (42.0)<br />

SBSC11 4 12 91 92 M8 F 395 (15.6) 105 (4.1) 264 (10.4) 28.0 (61.6)<br />

Notes:<br />

1 M = male stud, F = female thread<br />

2 supplied with wiring harness<br />

3 dimension includes top cover<br />

4 SBSB8, B10, B14, and C11 are available with terminals on the top face or on the front face.<br />

For front terminals add ‘FT Adapter’ to the model number<br />

5 SBSB8, B10 and B14 are available with a venting manifold, with a spigot at the front or back.<br />

The manifold increases monobloc height by 9mm.<br />