Product catalogue
Product catalogue
Product catalogue
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Product</strong> <strong>catalogue</strong> April 2012
Fenix was founded in 1990 as one of the fi rst private companies in the Czech Republic following the “Velvet”<br />
Revolution. The fi rst items produced were the successfully marketed ECOSUN electric radiant heating panels, however,<br />
as market demand increased these products were followed by ECOFLEX electric convectors, ECOFLOOR heating<br />
cables and mats and ECOFILM heating fi lms. The company also offers a wide range of supplementary products<br />
including heating system controls, cable kits and cable mats. With the increase in demand the structure of the company<br />
developed – for the reason of retaining maximum fl exibility a holding company structure was chosen, with individual<br />
and independent members.<br />
The following companies were incorporated successively: Fenix s.r.o. – plant producing electrical heating systems;<br />
Fenix Trading s.r.o. – trading company; Fenix Slovakia s.r.o. – production and trading company, representing<br />
FENIX in Slovakia; Fenix Group a.s. – a company which provides property management and services (strategic planning,<br />
administration of property, economic and fi nancial services); Flexel International Ltd. – manufacturing and trading<br />
company located in the United Kingdom. In 2008 FENIX Holding – acquired the production and trading company Aztec<br />
Europe Ltd., – manufacturer of special applications, such as mirror demisting heaters, vivarium heaters, caravan and
ECOSUN – radiant heating panels<br />
low and high temperature radiant ceiling panels<br />
pages 4–6<br />
MR – marble radiant panels for residential,<br />
commercial and individual application<br />
page 7<br />
GR – glass radiant panels for residential,<br />
commercial and individual application<br />
pages 8–9<br />
IRC PANELS – radiant heating for infrared cabins<br />
pages 10–11<br />
ECOFLOOR – heating cable systems<br />
heating cable circuits and cable mats,<br />
complete fl oor heating installation kits,<br />
deicing gutters and eaves troughs, snow-melting,<br />
de-icing outdoor surfaces, frost protection of pipes<br />
pages 12–25<br />
ECOFILM – heating fi lm systems<br />
E-set – underfl oor heating, kit for DIY installation<br />
F – underfl oor heating fi lm<br />
C – radiant ceiling heating fi lm,<br />
MHF – mirror fogging prevention<br />
pages 26–29<br />
ULTRATHERM – heating for vivariums and terrariums<br />
pages 30–31<br />
ECOFLEX – electric convectors<br />
classic and glass convection heaters<br />
pages 32–33<br />
THERMOSTATS AND CONTROLS<br />
regulation unit, control unit, room and fl oor sensors, and<br />
regulators for reduction of main circuit breaker value<br />
pages 34–36<br />
STORAGE HEATERS<br />
static and dynamic storage heaters<br />
page 37<br />
ATLANTIC – storage water heaters<br />
10 – 150 L volume<br />
page 38<br />
SUPPLEMENTARY PRODUCTS<br />
hand dryers, towel radiators<br />
page 38<br />
mobile home heating equipment. At the end of 2009/in early 2010 Fenix Holding acquired two other production and trading<br />
companies: ACSO – production and trading company with its headquarters in France; CEILHIT –producer of heating cables and<br />
trading company with its headquarters in Spain, covering the market in Spain, Portugal and South America.<br />
Presently, the company Fenix Holding s.r.o. is one of the largest European producers of surface electric heating systems,<br />
and currently exports to over 52 countries worldwide.
®<br />
ECOSUN<br />
Principle of infrared heating<br />
Whereas in convection heating the air is warmed by a convector<br />
which then transfers heat as it flows over the objects that<br />
are to be heated (walls, furniture), Radiant heating panels<br />
transfer heat mainly through radiant energy. Upon encountering<br />
objects (walls, furniture, floors), radiant energy is partially reflected<br />
(approx. 15 %), the majority (approx. 85 %) is absorbed by the<br />
objects. This radiant energy is converted to heating energy as it<br />
raises the temperature of the objects, which then transfer heat to<br />
the cooler air by convection.<br />
Thanks to unique technology Silicating, high temperature radiant<br />
panels reach high emissivity up to 0,98 mu.<br />
The principles mentioned create<br />
the following advantages:<br />
the surface of the radiant panel generates a heat flow<br />
whose spectrum is in the wavelength not greater than<br />
5 micrometers and is thus absorbed to a large degree<br />
by the human body: people are therefore heated<br />
in a manner similar to the objects in the room.<br />
when the radiant heat flow increases the temperature of<br />
the objects in the room of 20–22 °C, comfort conditions<br />
are achieved even with air temperatures of 18–19 °C<br />
which can lead to energy savings of 18–24 %.<br />
radiant panels permit the temperature distribution in<br />
a room to be more vertically balanced giving a 1–2<br />
degree difference between the floor and the ceiling<br />
(for convection heating the difference is given as<br />
1 °C per metre of height, 30–50 cm of height).<br />
there is less flow movement therefore dust particles due<br />
to brownian movement are less thus reducing the risk of<br />
illnesses – asthma, mucous membrane infection, etc.<br />
increased wall temperatures mean a lower<br />
possibility of surface condensation, albeit the<br />
humidity in the room is not lowered.<br />
glass is not “transparent” (we might say “transthermant”)<br />
when it comes to radiation with wavelengths over 3 and<br />
thus the radiant flow is not lost through windowpanes.<br />
the panels do not require maintenance<br />
Unique technologies<br />
Fenix utilises unique state-of-the art technology in respect of the finished panel surfaces. (Thermoquartz and Thermocrystal for low temperature<br />
panels and Silicating for high temperature panels).<br />
Radiant heating by ECosun<br />
4<br />
radiant heating panels<br />
Convection heating
LOW TEMPERATURE PANELS<br />
ECOSUN G – a glass radiant panel derived from GR panels. Slim profi le – just 20 mm (panel with frame). The panel is supplemented<br />
with thermal insulation, with a frame from eloxed aluminium and versatile fi xtures which enable installation both on a wall (vertically)<br />
and on the ceiling (horizontally). This makes it a versatile product which combines the advantages of ECOSUN radiant panels and the<br />
design of GR glass panels. Protection class II; length of supply cables 1 m. Option of installing on a class C or D fl ammable base.<br />
TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.<br />
ECOSUN G 300 white 300<br />
600×600×50* 7<br />
40 5437110<br />
ECOSUN G 600 white 600 1200×600×50* 14 20 5437112<br />
ECOSUN G 300 black<br />
ECOSUN G 600 black<br />
300<br />
600<br />
230 IP 44<br />
600×600×50*<br />
1200×600×50*<br />
7<br />
14<br />
vertical or horizontal<br />
position<br />
40<br />
20<br />
5437116<br />
5437118<br />
ECOSUN G 300 mirror 300 600×600×50* 10,2 40 5437126<br />
ECOSUN G 600 mirror 600 1200×600×50* 19 20 5437128<br />
* Thickness includes mounting fi xture, which is an inseparable part of the panel.<br />
ECOSUN E – an alternative version of the ECOSUN G glass radiant panel. Slim profi le – just 20 mm (panel with frame).<br />
For this panel, the front glass has been substituted by a panel with a plastic powder coating; is suitable e.g. for health care<br />
applications. Protection class II; length of supply cables 1 m. Option of installing on a class C or D fl ammable base.<br />
TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.<br />
ECOSUN E 300 white 300<br />
ECOSUN K+ – heating panel used for warming church pews, desks in offi ces and administrative buildings. They can be<br />
hung on a wall in the standard way; for installation on the ceiling it is necessary to order a ceiling frame. Class I.<br />
Basic colour: brown, white Connection cable: 50 cm for 100–270 K+, 75 cm for 330–400K+<br />
TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.<br />
ECOSUN 100 K+ 100<br />
500×320×30 2,5<br />
60 5401200<br />
ECOSUN 200 K+<br />
ECOSUN 270 K+<br />
ECOSUN 330 K+<br />
200<br />
270<br />
330<br />
230 IP 44<br />
750×320×30<br />
1000×320×30<br />
1250×320×30<br />
3,7<br />
5,2<br />
6,6<br />
vertical or horizontal<br />
position<br />
45<br />
30<br />
30<br />
5401205<br />
5401210<br />
5401215<br />
ECOSUN 400 K+ 400 1500×320×30 7,9 30 5401220<br />
Ceiling fi xing frame for ECOSUN 100 K+, 200 K+, 270 K+, 330 K+, 400 K+<br />
ECOSUN U – universal panel for dwelling and non-dwelling spaces, possibly mounted onto ceilings or into suspended ceilings. Class I.<br />
Basic colour: white Connection cable: 100 cm<br />
TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.<br />
ECOSUN 300 U 300<br />
230 IP 44<br />
5<br />
600×600×50* 6,6<br />
vertical or horizontal<br />
position<br />
40 5437140<br />
ECOSUN E 600 white 600 1200×600×50* 11,3 20 5437142<br />
* Thickness includes mounting fi xture, which is an inseparable part of the panel.<br />
592×592×30 5,0 from 2,5 m 40 5401037<br />
ECOSUN 600 U 600 230 IP 44<br />
10,1 from 2,5 m 20 5401047<br />
1192×592×30<br />
ECOSUN 700 U 700 10,5 from 2,7m 20 5401171<br />
ALUMINIUM FRAME – is intended for ECOSUN panels and has a purely aesthetic function. The body of the panel is composed of two<br />
parts riveted together. Neither the gap formed by the connection of the front and rear parts nor the riveting itself are usually particularly<br />
visible in the case of ceiling installation. However, if required the panel can be fi tted with the aluminium frame, which covers the join.<br />
TYPE Cat. No.<br />
Aluminium frame for ECOSUN 300U 5401228<br />
Aluminium frame for ECOSUN 600U/700U 5401229<br />
ECOSUN C/VT – heating panels only for mounting into suspended ceilings. Class I.<br />
Basic colour: white<br />
TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.<br />
ECOSUN 300 c 600/VT 300<br />
574×574×35 4,6 min. 2,5 m 40 5401065<br />
230 IP 20<br />
ECOSUN 600 c 600/VT 600 574×1174×35 9,4 min. 2,5 m 20 5401075
ECOSUN IKP, IN, IN-2 – panels for industrial and agricultural applications (i.e. in workshops, greenhouses, livestock facilities). Class I.<br />
Basic colour: brown Connection cable: 100 cm<br />
TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Quantity on pallet Cat. No.<br />
ECOSUN 700 IKP 700<br />
HIGH TEMPERATURE PANELS<br />
ECOSUN S / SB – for industrial halls, gyps, halls, workshops, wit coverage that corresponds to the given environment.<br />
Suitable for drying of buildings. Class I. Covering IP x4. Basic colour: white (RAL 9002). For spaces with higher<br />
humidity – agricultural structures, washing facilities, panels are produced in a corrosion-proof version SBs – stainless.<br />
HALOGEN HEATERS<br />
ECOSUN 700 IN 700 230 IP 65<br />
ECOSUN 700 IN-2 700<br />
IP 65<br />
E Ex 2<br />
Ceiling fi xing frame for type IKP, IN, IN-2<br />
TYPE [W] [V] Weight [kg] Quantity on pallet Recommended clearance [m] Dimmensions [mm] Cat. No.<br />
ECOSUN S 09<br />
ECOSUN S 12<br />
ECOSUN S 18<br />
ECOSUN S 24<br />
ECOSUN S 30<br />
ECOSUN S 36<br />
900<br />
1200<br />
1800<br />
2400<br />
3000<br />
3600<br />
230<br />
230 / 400<br />
2N<br />
8<br />
12,6<br />
16,6<br />
58<br />
39<br />
26<br />
According to individual<br />
conditions,<br />
for full area 5–8 m,<br />
zonal 3,4–4,5 m<br />
1500×150×60<br />
1500×250×60<br />
1500×350×60<br />
5401409<br />
5401412<br />
5401418<br />
5401424<br />
5401430<br />
5401436<br />
TYPE [W] [V] Weight [kg] Quantity on pallet Recommended clearance [m] Dimmensions [mm] Cat. No.<br />
ECOSUN SBs 09<br />
ECOSUN SBs 12<br />
ECOSUN SBs 18<br />
ECOSUN SBs 24<br />
ECOSUN SBs 30<br />
ECOSUN SBs 36<br />
900<br />
1200<br />
1800<br />
2400<br />
3000<br />
3600<br />
230<br />
230 / 400<br />
2N<br />
6<br />
10,8<br />
14,1<br />
75<br />
45<br />
30<br />
According to individual<br />
conditions,<br />
for full area 5–8 m,<br />
zonal 3,4–4,5 m<br />
1500×130×50<br />
1500×230×50<br />
1500×330×50<br />
5401709<br />
5401712<br />
5401718<br />
5401724<br />
5101730<br />
5401736<br />
TILTABLE BRACKET – a tiltable bracket enables the installation of ECOSUN S/SBs panels at an angle, and thus the aiming of the heat fl ow<br />
at the required area. The bracket can be used for ceiling as well as wall installation; the package contains 1 pair of brackets (two pieces).<br />
TYPE Cat. No.<br />
Halogen heaters – the high surface temperature of halogen tubes enables the use of the radiators in<br />
areas where normal radiant panels wouldn’t be effective – for example, in outdoor areas for the heating<br />
of terraces and balconies, or for the heating of large industrial halls with no heat cladding.<br />
TYPE [W] [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance [m] Cat. No.<br />
HWP 1500 1500<br />
IP 54 1192×592×30 9,3 2,5–3,0 20 5401176<br />
Tiltable bracket for ECOSUN S 9–12 5401797<br />
Tiltable bracket for ECOSUN S 18–36 5401798<br />
Tiltable bracket for ECOSUN SBs 09–36 5401795<br />
PROTECTIVE GRILLE – the protective grille protects the lamellas of ECOSUN S high-temperature<br />
panels against mechanical damage (for example, by a ball in a gym) and simultaneously prevents<br />
objects from coming into direct contact with the hot surface of the heating lamellas.<br />
TYPE Cat. No.<br />
Protective grille for ECOSUN S 9–12 5401790<br />
Protective grille for ECOSUN S 18–24 5401792<br />
Protective grille for ECOSUN S 30–36 5401794<br />
IP 55 480×120×120 1,7 2,2–3,0 m 8102010<br />
HN 4500 4500 230<br />
590×430×140 6,5 3,0–4,5 m 8102035<br />
IP 21<br />
HN 6000 6000 590×430×140 6,5 3,5–5,5 m 8102040<br />
6<br />
1192×592×30 9,5<br />
2,8–3,3 20 5401181<br />
3,0–3,5 20 5401186
RADIANT PANELS<br />
MR – marble radiant panels<br />
MR marble radiant panels are primarily intended for heating<br />
reception rooms, halls, bathrooms and others.<br />
MR panel has an extremely aesthetic appearance and the radiant<br />
heat from this natural material is very acceptable. The MR<br />
panel consists of a robust polished marble plate, a heating element,<br />
limiting thermostat , and a connection cable. This panel is<br />
intended to be installed as a fi xed installation on a wall with the<br />
connection cable connected to the installation box. These panels<br />
are manufactured in various power outputs and are available in<br />
5 marble designs.<br />
As marble is a natural material there is the possibility of small<br />
colour and texture variances.<br />
MR PANELS – marble radiant panels (thermo fuse), IP 44, class II; Connection cable for 300–1000:100 cm, 1200: 150 cm;<br />
Type of marble: Kavala, Volakas, Janina, Rosa, Veria Green;<br />
Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm<br />
IP 44<br />
TYPE OUTPUT [W] Dimensions [mm] Weight [kg]<br />
7<br />
Quantity<br />
on pallet / in crate<br />
MR300 300 500×500×30 20 10 / 22<br />
Marble Cat. No.<br />
5438000<br />
MR500 500 700×500×30 28 10 / 20 5438005<br />
MR800 800 900×600×30 43 5 / 11 Volakas 5438010<br />
MR1000 1000 1100×600×30 53 5 / 11 5438015<br />
MR1200 1200 1300×600×30 62 5 / 7 5438020<br />
MR300 300 500×500×30 20 10 / 22<br />
5438200<br />
MR500 500 700×500×30 28 10 / 20 5438205<br />
MR800 800 900×600×30 43 5 / 11 Kavala 5438210<br />
MR1000 1000 1100×600×30 53 5 / 11 5438215<br />
MR1200 1200 1300×600×30 62 5 / 7 5438220<br />
MR300 300 500×500×30 20 10 / 22<br />
5438050<br />
MR500 500 700×500×30 28 10 / 20 5438055<br />
MR800 800 900×600×30 43 5 / 11 Janina 5438060<br />
MR1000 1000 1100×600×30 53 5 / 11 5438065<br />
MR1200 1200 1300×600×30 62 5 / 7 5438070<br />
MR300 300 500×500×30 20 10 / 22<br />
5438100<br />
MR500 500 700×500×30 28 10 / 20 5438105<br />
MR800 800 900×600×30 43 5 / 11 Rosa 5438110<br />
MR1000 1000 1100×600×30 53 5 / 11 5438115<br />
MR1200 1200 1300×600×30 62 5 / 7 5438120<br />
MR300 300 500×500×30 20 10 / 22<br />
5438250<br />
MR500 500 700×500×30 28 10 / 20 5438255<br />
MR800 800 900×600×30 43 5 / 11 Veria Green 5438260<br />
MR1000 1000 1100×600×30 53 5 / 11 5438265<br />
MR1200 1200 1300×600×30 62 5 / 7 5438270
GR – glass radiant panels<br />
GR glass radiant panels feature an attractive and timeless design.<br />
Due to the aesthetic appearance these panels are primarily intended<br />
for heating reception rooms, offi ces and others. Glass panels<br />
consist of a 12 mm toughened glass plate heating element, thermo<br />
fuse, and connection cable. They are designed to be mounted on<br />
a wall connecting the connection cable to the wiring box.<br />
GR panels<br />
GR PANELS – glass panels (thermo fuse), IP 44, class II; Connection cable: 100 cm; Panels are manufactured<br />
in 4 series with different outputs. GR panels you can choose from fi ve colours: mirror, white, black, red, yellow-green;<br />
Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm<br />
TYPE Output [W] Dimensions [mm] Weight [kg]<br />
8<br />
Quantity<br />
on pallet / in crate<br />
GR 300 300 700×500×12 14 10 / 22 pcs<br />
Glass colour Cat. No.<br />
543760x<br />
GR 500 500 900×600×12 21 5 / 12 pcs 543761x<br />
white, black, red,<br />
yellow-green<br />
GR 700 700 1100×600×12 26 5 / 12 pcs 543762x<br />
GR 900 900 1200×800×12 38 5 / 8 pcs 543763x<br />
GR 500 500 900×600×8 21 5 / 12 pcs<br />
5437611<br />
mirror<br />
GR 900 900 1200×800×8 38 5 / 8 pcs 5437631<br />
GR SET – panels with wireless regulation<br />
Use: These types are derived from standard GR panels but they are additionally fi tted with an integrated BPT-SP2 wireless receiver (see<br />
the chapter THERMOSTATS AND CONTROLS) and a supply lead fi tted with a plug. A wireless programmable thermostat is supplied<br />
with every panel as part of the package and so it is possible that, after unpacking the product, hanging it on the wall and connecting<br />
it to the socket, the panel can be operated immediately, without any assistance from a specialized installation company. The panels are<br />
intended mainly for supplementary installation, without the necessity of intervention into the existing electrical system. GR SET panels can<br />
be supplemented with chromium-coated supports (see page 9) and thus a very aesthetic and convenient portable heater can be created.<br />
Glass colours: white, black, yellow-green, red and mirror.<br />
IP 44<br />
TYPE Output [W] Dimensions [mm] Weight [kg] Glass colour Cat. No.<br />
GR Set 300 300 700×500×12 14,9<br />
543770x<br />
GR Set 500 500 900×600×12 21<br />
white, black, red,<br />
543771x<br />
GR Set 700 700 1100×600×12 28,4<br />
yellow-green<br />
543772x<br />
GR Set 900 900 1200×800×12 38 543773x<br />
GR Set 500 500 900×600×8 20<br />
5437711<br />
mirror<br />
GR Set 900 900 1200×800×8 37 5437731
SUPPORTS FOR GR PANELS – for applications where<br />
the GR panel cannot be hung on a wall (e.g. in the case<br />
of glass surfaces), a set of chromium plated supports can<br />
be used for the placement of the panels on the fl oor.<br />
The GR panel is inserted into apertures in the supports and subsequently the supports<br />
are affi xed to the panels with the help of adjustment screws. The panel is stable on these<br />
supports; the bottom edge of the panel is 55 mm above the fl oor. For permanent installations,<br />
we recommend that the supports are attached to the fl oor using screws – in the<br />
base there are two openings with a diameter of 6 mm for screws with countersunk heads.<br />
The supports are intended for use only with the GR type and are only for horizontal<br />
installation. In the case of vertical installation (particularly for GR 1000 panels), there<br />
is a signifi cantly higher risk that the user may accidentally knock the panel over. GR<br />
panels on supports must not be exposed to excessive pressure – there is a danger of<br />
tipping if it is placed freely, and if the supports are attached to the fl oor, there is a risk<br />
of damage to the glass in the places where supports are attached.<br />
NOTIFICATION<br />
PRODUCT Cat. No.<br />
Supports for GR panels<br />
Contents of the set: chromium plated supports<br />
– 2 pcs (base diameter 130 mm), plastic covers<br />
for the brackets for the GR panel – 4 pcs, mains<br />
plug (to be installed on the supply lead if the<br />
panel is to be used as a mobile heater)<br />
8000100 TYPE Description Weight [kg] Cat. No.<br />
Simple towel rail (width 500 mm) GR (SET) 300 0,9 5437810<br />
Simple towel rail (width 600 mm) GR (SET) 500 and 700 1,05 5437812<br />
Simple towel rail (width 800 mm) GR (SET) 900 1,2 5437818<br />
Double towel rail (width 500 mm) GR (SET) 300 1,8 5437820<br />
Double towel rail (width 600 mm) GR (SET) 500 and 700 2,1 5437822<br />
Double towel rail (width 800 mm) GR (SET) 900 2,4 5437824<br />
ECOSUN, MR and GR radiant panels are only equipped with a limiting thermostat – suitable regulation is essential for correct and economical<br />
operation; see the chapter THERMOSTATS AND CONTROLS. In the case of GR and GR SET glass panels, the limiting thermostat switches<br />
off the panels at an average temperature of 90 °C, and therefore the real thermal output of the panels is approximately 10 % lower than the<br />
wattage. For this reason and also for the improvement of the dynamics of the whole heating system, we recommend that the installed wattage<br />
is increased by 20 % in contrast with the result of the heat loss calculation. GR and GR SET panels can be supplemented with chromium-coated<br />
supports which enable the panel to be placed on the fl oor – e.g. in proximity to glass surfaces or to create a stylish portable heater.<br />
9<br />
STAINLESS STEEL TOWEL RAIL<br />
– for GR/GR SET 300, 500, 700 and 900 panels<br />
These Towel rail – designed as an accessory for GR and GR SET<br />
radiant glass panels in all colour versions. It is made from a 4×30 mm<br />
polished stainless steel sheet. After its installation, the standard panel is<br />
transformed into a smart bathroom heater with a rail on which a towel<br />
or bath towel can be hung.<br />
The rail is intended only for panels installed vertically; however, the installation itself<br />
is very easy. The openings in the back part of the rail are simply placed onto the top<br />
two screws of the panel by which the heater will be attached to the wall. The panel is<br />
then placed into the prepared hanging brackets. After the attachment nuts have been<br />
tightened, the rail, which is placed between the back part of the panel and the hanging<br />
bracket, is attached fi rmly. The rail is in the shape of a rectangle with the dimensions<br />
530×90 mm; the distance between the attachment openings is 260 mm.
IRC PANELS radiant heating for infrared cabins<br />
The principle behind infrared<br />
cabins (infrared saunas)<br />
In infrared cabins (also called infrared saunas), so-called radiant<br />
heat is used – it works on a similar principle to ECOSUN heating<br />
panels. In this case, however, it is aimed at warming the muscle<br />
tissue of the user up to a depth of approximately 4 cm with the help<br />
of infrared radiation. Thanks to this deep warming of the organism,<br />
intensive sweating takes places at a lower air temperature<br />
than in the case of classic steam saunas – during the whole of the<br />
user’s stay in the cabin, the air temperature ranges between 30<br />
and approx. 55 °C.<br />
Infrared cabins can be used over longer intervals, with the aim of<br />
freeing one’s body from harmful substances which are released<br />
when sweating, or in shorter intervals in which the aim is to warm<br />
up the muscle tissue before expected physical exercise – muscle<br />
stretching, body-building, running etc.<br />
10<br />
Advantages of infrared<br />
cabins with IRC panels<br />
Infrared heating warms up the skin faster and the heat also<br />
penetrates deeper into the tissues than heat from hot steam<br />
Thanks to the lower air temperatures involved, they<br />
are also suitable for patients with cardiovascular<br />
diseases or respiratory diseases<br />
In contrast with other types, they have considerably<br />
lower acquisition costs and minimum negative infl uences<br />
on the surrounding environment – humidity<br />
The operation costs are lower by 1/3 to 1/2 in comparison<br />
with steam saunas (lower air temperature in the cabin; up<br />
to 80 % of energy is used for direct heating of the body)<br />
Large-surface IRC radiant panels heat evenly across their<br />
whole surface and for example in contrast with ceramic<br />
radiators, the performance of which is concentrated<br />
into a small surface with a high temperature, they heat<br />
the whole body signifi cantly better and more evenly<br />
The possibility of minimizing spatial requirements<br />
– a cabin can be installed in an area as small<br />
as 1 m2 – suitable also for smaller fl ats<br />
Modular assembly without the necessity to use special<br />
tools in connection with the IRT regulator – the option<br />
of assembling the infrared cabin without expert aid
IRC RADIANT PANELS – FENIX has manufactured and supplied IRC panels for foreign producers of infrared cabins (Austria, Germany)<br />
since 2004. Now it is offering these panels on the Czech market together with a control unit – IRT regulator – and this also as a DIY kit.<br />
IP 44 PRODUCT Output [W] Voltage [V] Weight [kg] Dimensions [mm] Cat. No.<br />
IRC Panel 1130x360/200 200<br />
875x360 5401805<br />
IRC Panel 1130x360/260 260 5,9 1130×360 5401810<br />
IRC Panel 1330x360/310 310 1330x360 5401811<br />
IRC Panel 650x780/330 330 230<br />
650x780 5401813<br />
IRC Panel 1130x780/575 575 11,5 1130×780 5401812<br />
IRC Panel 1130x780/575 S (with a probe) 575 11,5 1130×780 5401814<br />
IRC Panel 1330x780/680 S (with a probe) 680 1330×780 5401815<br />
CONTROL UNIT – IRT 01 REGULATOR – The IRT regulator maintains a set temperature on the surface of radiant panels, as well as the<br />
required operating time of the heating and lighting of the infrared cabin. It contains a power unit (installed within a cavity under the bench) to<br />
which IRC panels are connected using plugs, and also a control unit, light and supply cable. Up to 6 IRC panels can be connected. All IRC<br />
panels are equipped with a special connector and the offered sizes can be combined as needed; however, the total wattage mustn’t exceed<br />
3.4 kW and one (only one) of the panels used must have an integrated temperature sensor. The power unit is connected to a 230 V socket,<br />
protected with a 30 mA residual current device.<br />
IP 44 DESCRIPTION Cat. No.<br />
IRT 01 REGULATOR<br />
Temperature setting 20–80 °C;<br />
time setting 1 to 99 minutes; switch<br />
Set contents: control unit including a connection cable; power unit with connectors;<br />
3 m power cable with plug (230 V / 16 A); 3 m connection cable for lighting (light is<br />
not included in the set); instructions; screws – 8 pcs.<br />
Set selection<br />
According to the size of the infrared cabin you wish to install, choose and combine the offered<br />
panel sizes in such a way that they best cover the space within the infra-red cabin – the lower<br />
and upper halves of the body. It is ideal if the panels surround the user on at least three sides.<br />
There can be a maximum of six panels for every control unit, from which one (but<br />
only one) must be equipped with an integrated temperature probe. The maximum<br />
wattage of all the panels attached to one control unit can be up to 3.4 kW.<br />
An IRT-01 regulator is necessary to control the panels. The regulator comes with<br />
the set, which includes a control panel and power unit. The control panel should<br />
be installed inside the infrared cabin within reach of the user. The power unit is<br />
installed in a cavity under the bench and should not be easy to access.<br />
The connecting leads for the IRC panels are, after installation on the wall, connected<br />
to the power unit with the aid of connectors – the connectors from the panels, lighting,<br />
control units and connecting leads have different dimensions, so it isn’t possible<br />
to confuse them and connection can be carried out by a non-expert user.<br />
If lighting is required it is also possible to connect a light to the power<br />
unit; a connection cable comes as part of the set.<br />
It is necessary to equip panels with a suitable protective cover, allowing the correct<br />
operation of the panel. We recommend using the wooden covering frames that are<br />
offered, as they are constructed size-wise to exactly fi t the dimensions of the IRC panels<br />
Wooden frames not only fulfi l a protective function, but also attach panels to walls<br />
– the panels alone are not fi tted with any mounting apertures or brackets.<br />
11<br />
4200040
®<br />
ECOFLOOR<br />
ECOFLOOR electric fl oor heating systems ensure ideal heat distribution<br />
and, by decreasing undesirable air circulation, reduce dust<br />
levels. These systems offer great comfort, economic and reliable<br />
operation, and long lifetime. They preserve free fl oor space by<br />
eliminating the need for various heating elements, radiators and<br />
heat distribution systems. The principal advantage of electric fl oor<br />
heating is easy and separate temperature control in individual<br />
rooms. Once installed, it is completely maintenance free.<br />
We provide 10 year warranty for underfl oor heating<br />
cables and mats and 2 year warranty for cables used<br />
for outdoor application (gutter, eaves, pipes).<br />
12<br />
Cable ASL1P<br />
heating mats LD<br />
Cable ADSV-T<br />
heating mats LDTS, LSDTS<br />
Cable ADSV<br />
heating circuits ADSV<br />
Cable ADSV+<br />
heating circuits ADSV+<br />
Cable ADSA<br />
ultrathin mats CM<br />
underfl oor heating systems<br />
Overview of ECOFLOOR heating cables and recommended usage<br />
Type<br />
Wattage [W/m]<br />
Number of heating cores<br />
Protective screen<br />
Protection against UV radiation<br />
Thermal endurance of the jacket<br />
*) for a short term (installation under asphalt)<br />
Supplied as circuit<br />
Supplied as mat<br />
Direct-heating<br />
Floor heating<br />
Semi-storage<br />
Storage<br />
Surfaces<br />
Anti-freeze<br />
protection of<br />
10 ●<br />
● ● ●<br />
ASL1P 15 1 ● 70 °C ● ● ●<br />
18 ● ● ● ●<br />
10 ●<br />
● ● ●<br />
ADSV 15 2 ● 70 °C ● ● ●<br />
18 ● ● ● ●<br />
ADSV-T 12 2 ● 70 °C ● ●<br />
10 ● ●<br />
● ●<br />
ADSV+ 18 2 ● ● 80 °C ● ●<br />
20 ● ● ● ●<br />
ADSA 12 2 ● 70 °C ● ●<br />
10 ● ●<br />
● ●<br />
ADPSV 18 2 ● ● 80 °C ● ● ● ●<br />
20 ● ● ● ●<br />
PSV<br />
10<br />
15<br />
1<br />
●<br />
●<br />
70 °C<br />
●<br />
●<br />
●<br />
●<br />
●<br />
●<br />
20 ● ●<br />
● ● ● ● ●<br />
MAPSV 25 1 ● ● 80 °C ● ●<br />
30 ● ● ● ● ●<br />
15 ● ●<br />
● ● ● ● ● ●<br />
MADPSP<br />
20<br />
25<br />
2<br />
●<br />
●<br />
●<br />
●<br />
90 °C<br />
240 °C*<br />
●<br />
●<br />
●<br />
●<br />
● ●<br />
●<br />
●<br />
●<br />
●<br />
●<br />
30 ● ● ● ● ●<br />
PDSP 28 2 ● ●<br />
90 °C<br />
200 °C*<br />
● ●<br />
PFP 12 2 ● ● 70 °C ● ●<br />
PDS1P 40 2 ● 70 °C ● ●<br />
Roofs<br />
Pipes
Overview of special ECOFLOOR heating<br />
cables and recommended usage<br />
Type<br />
Wattage [W/m]<br />
Overview of ECOFLOOR heating mats and recommended usage<br />
Cable PSV<br />
heating circuits PSV, heating mats LPSV<br />
Cable ADPSV<br />
heating circuits ADPSV<br />
Cable MAPSV<br />
heating circuits MAPSV, heating mats MST<br />
Cable MADPSP<br />
heating circuits MADPSP, heating mats MDT<br />
Cable PDSP<br />
heating circuits PDSP<br />
Cable PDS1P<br />
for curing concrete<br />
Number of heating cores<br />
Protective screen<br />
Protection against UV radiation<br />
Thermal endurance of the jacket<br />
Supplied as circuit<br />
Supplied as mat<br />
Direct-heating<br />
Floor heating<br />
Semi-storage<br />
Storage<br />
Surfaces<br />
Anti-freeze<br />
protection of<br />
ELSR-M<br />
10<br />
15<br />
2<br />
●<br />
●<br />
●<br />
●<br />
65 °C<br />
●<br />
●<br />
●<br />
●<br />
ELSR-N<br />
20<br />
30<br />
2<br />
●<br />
●<br />
●<br />
●<br />
80 °C<br />
●<br />
●<br />
●<br />
●<br />
●<br />
●<br />
PCC 30 1 ● −40…60 °C ●<br />
PC<br />
25<br />
50<br />
2 −50…60 °C<br />
●<br />
●<br />
PC-S<br />
20<br />
25<br />
2<br />
●<br />
●<br />
−50…60 °C<br />
●<br />
●<br />
Type<br />
Wattage [W/m]<br />
Number of heating cores<br />
Protective screen<br />
Protection against UV radiation<br />
Thermal endurance of the jacket<br />
Direct-heating<br />
Floor heating<br />
CM 150 2 ● 90 °C ● ADSA<br />
80 ●<br />
● ●<br />
LDTS 100 2 ● 70 °C ● ●<br />
ADSV-T<br />
160 ● ● ●<br />
LD 160 1 ● 70 °C ● ● ASL1P<br />
LSDTS<br />
100<br />
160<br />
2<br />
●<br />
●<br />
70 °C<br />
●<br />
●<br />
ADSV-T<br />
LPSV 100 1 ● 80 °C ● PSV<br />
MST 300 1 ● ● 80 °C ● MAPSV<br />
MDT 300 2 ● ● 90 °C ● ● MADPSP<br />
Semi-storage<br />
Storage<br />
Heating of outdoor areas<br />
Roofs<br />
Type of heating cable<br />
Pipes<br />
13<br />
Cable composition markings<br />
1 2 3 4 5 6<br />
M A D P S P<br />
1 Resistance (heating) wire<br />
M multi-resistance – stranded resistance wire<br />
(to be used for higher outputs);<br />
no letter is used for a non-stranded (simple) resistance wire<br />
2 Core insulation<br />
A FEP (fl uoropolymer)<br />
P XLPE (cross-linked polyethylene)<br />
3 Number of heating cores<br />
D double-core cable;<br />
no letter is used for a single-core cable<br />
4 Plastic insulation (for outdoor applications,<br />
higher mechanical ruggedness of cable)<br />
P XLPE (cross-linked polyethylene);<br />
no letter is used for a cable without<br />
the second plastic insulation<br />
5 Protection screen (for wet areas)<br />
S full screen protection (tinned copper<br />
wires and aluminium tape)<br />
SL linear screen protection<br />
no letter is used for a cable without screen protection<br />
6 Jacket<br />
P XLPE (cross-linked polyethylene)<br />
1P PP-LDPE (mixed polypropylene & low density PE)<br />
V PVC (polyvinyl chloride)<br />
Cable ELSR-M<br />
self-regulating cable for anti-freeze protection and<br />
technological heating (10 and 15 W/m)<br />
Cable ELSR-N<br />
self-regulating cable for anti-freeze protection and<br />
technological heating (20 and 30 W/m EExII)<br />
PCC cable<br />
heating circuits for anti-freeze protection –<br />
heating of the insulating door seals of freezers<br />
PC cable<br />
heating cable with a constant linear wattage for<br />
anti-freeze protection and process heating<br />
PC-S cable<br />
armoured heating cable (metal braiding)<br />
with a constant linear wattage for anti-freeze<br />
protection and process heating<br />
Linear input of cable [W/m]<br />
2 0 2 4 0<br />
Total input of circuit [W]
DIRECT HEATING SYSTEMS<br />
ECOFLOOR CABLES AND MATS<br />
ECOFLOOR heating systems are available in two basic variants – heating cable circuits and heating mats.<br />
In fact the two systems do not differ from one another very much. In both cases, the heating system consists of a heating<br />
cable, either separate or fi xed to a supporting fi breglass cloth (heating mat). This modern fl oor heating system permits easy<br />
and effective regulation. The heating cable circuit or mats are placed directly beneath tiles in a thin layer of permanently<br />
fl exible cement so the tiled surface heats up relatively quickly (circa 20 min). Temperature control is sensitive and quick to<br />
react. Heating cable circuits or mats are suitable for renovated fl oors where the fi nal fl oor height is not a constraint.<br />
DIRECT HEATING SYSTEM<br />
1 wear layer (ceramic fl oor tiling)<br />
2 fl exible bonding cement<br />
3 ECoFLooR ® heating mat<br />
4 fl oor (limitation) probe in a protective tube (so-called goose neck)<br />
5 load-bearing concrete fl oating board<br />
6 steel reinforcement (so-called Kari mesh)<br />
7 thermal insulation<br />
8 base (concrete board)<br />
14<br />
DIRECT HEATING SYSTEM—RECONSTRUCTION<br />
1 wear layer (ceramic fl oor tiling)<br />
2 fl exible bonding cement<br />
3 heating mat (cable) ECoFLooR ®<br />
4 fl oor (limitation) probe in a protective tube (so-called goose neck)<br />
5 F-BoARD supplementary thermal insulation<br />
(shortens the warming time) (see page 25)<br />
6 fl exible bonding cement<br />
7 original fl oor (old fl oor tiling, concrete)
ECOFLOOR HEATING MATS<br />
LDTS or LSDTS (self-adhesive) heating mat, twin conductor cable with a full protection<br />
screen, width 50 cm, cold lead 1×3 m. LDTS mats are provided with selfadhesive<br />
tape for affi xing to the fl oor. LSDTS mats have a self-adhering<br />
mesh on their entire back surfaces.<br />
LDTs / LsDTs packing<br />
OUTPUT Type<br />
[W] 160 W/m2 Surface<br />
[m2 LDTS / LSDTS 160 W/m<br />
Length Cat. No. Cat. No.<br />
] [m] LDTS LSDTS<br />
70 160/0.5 0,5 0,9 5530200 5531005<br />
130 160/0.8 0,8 1,6 5530205 5531010<br />
210 160/1.3 1,3 2,6 5530210 5531015<br />
260 160/1.6 1,6 3,2 5530220 5531020<br />
340 160/2.1 2,1 4,2 5530230 5531025<br />
410 160/2.6 2,6 5,2 5530240 5531030<br />
500 160/3.0 3,0 6,0 5530250 5531035<br />
560 160/3.4 3,4 6,7 5530255 5531040<br />
670 160/4.2 4,2 8,3 5530260 5531045<br />
810 160/5.1 5,1 10,2 5530270 5531050<br />
1000 160/6.1 6,1 12,3 5530280 5531055<br />
1210 160/7.6 7,6 15,1 5530290 5531060<br />
1400 160/8.8 8,8 17,6 5530190 5531080<br />
1800 160/11.0 11,0 22,0 5530192 5531085<br />
2150 160/13.3 13,3 26,6 5530194 5531090<br />
2600 160/16.3 16,3 32,5 5530196 5531095<br />
2<br />
LDTs / LsDTs<br />
heating mat<br />
OUTPUT Type<br />
[W] 100 W/m2 Surface<br />
[m2 LDTS / LSDTS 100 W/m<br />
Length Cat. No. Cat. No.<br />
] [m] LDTS LSDTS<br />
60 100/0.6 0,6 1,2 5530401 5531105<br />
105 100/1.0 1,0 2,1 5530403 5531110<br />
180 100/1.8 1,8 3,6 5530405 5531115<br />
220 100/2.2 2,2 4,4 5530410 5531120<br />
290 100/2.9 2,9 5,8 5530415 5531125<br />
410 100/4.1 4,1 8,2 5530420 5531130<br />
460 100/4.7 4,7 9,4 5530425 5531135<br />
560 100/5.6 5,6 11,2 5530430 5531140<br />
820 100/8.2 8,2 16,5 5530440 5531145<br />
1000 100/10.2 10,2 20,3 5530450 5531150<br />
1200 100/11.8 11,8 23,7 5530460 5531155<br />
1800 100/17.9 17,9 35,8 5530470 5531160<br />
2<br />
Heating mats LDTS available also 120 W/m 2 and 150 W/m 2 .<br />
LD heating mat, single conductor cable with a full protection screen, width up to 3 m 2 –<br />
30 cm, over 3 m 2 – 50 cm, cold lead 2×5 m<br />
LD mat<br />
Packing in PE foil.<br />
LD 160 W/m 2<br />
OUTPUT<br />
[W]<br />
Type LD<br />
160 W/m 2<br />
ECOFLOOR Installation – Heating Mat<br />
1) Unroll the heating mat according to the layout drawing.<br />
2) If you need to leave a space under fi xed furniture, cut out the necessary part of the cloth and span the space with the cable (see fi g. 2).<br />
3) Level the layer of fl exible cement with a smooth trowel.<br />
4) Lay tiling on small areas (up to 4 m 2 ) immediately, and on larger areas after 24 hours.<br />
Surface<br />
[m 2 ]<br />
15<br />
Width<br />
[m]<br />
Length<br />
[m]<br />
Cat. No.<br />
100 160/0.6 0,6 0,3 2,0 5530005<br />
150 160/0.9 0,9 0,3 3,0 5530007<br />
180 160/1.1 1,1 0,3 3,6 5530010<br />
300 160/1.8 1,8 0,3 6,1 5530020<br />
360 160/2.3 2,3 0,3 7,6 5530030<br />
500 160/3.0 3,0 0,3 10,0 5530040<br />
700 160/4.3 4,3 0,5 8,6 5530050<br />
850 160/5.3 5,3 0,5 10,6 5530060<br />
950 160/5.9 5,9 0,5 11,8 5530070<br />
1150 160/7.2 7,2 0,5 14,4 5530080<br />
1700 160/10.7 10,7 0,5 21,4 5530090<br />
2000 160/12.4 12,4 0,5 24,9 5530100<br />
2500 160/15.7 15,7 0,5 31,3 5530110<br />
3000 160/18.8 18,8 0,5 37,6 5530120<br />
LDTS 160 W/m 2<br />
OUTPUT<br />
[W]<br />
LDTS 80 W/m 2<br />
OUTPUT<br />
[W]<br />
Type<br />
160 W/m 2<br />
Type<br />
80 W/m 2<br />
Surface<br />
[m 2 ]<br />
Surface<br />
[m 2 ]<br />
Length<br />
[m]<br />
Length<br />
[m]<br />
Cat. No.<br />
LDTS<br />
80 160-0,5 0,5 1,0 5540001<br />
160 160-1 1,0 2,0 5540002<br />
240 160-1,5 1,5 3,0 5540003<br />
320 160-2 2,0 4,0 5540004<br />
400 160-2,5 2,5 5,0 5540005<br />
480 160-3 3,0 6,0 5540006<br />
560 160-3,5 3,5 7,0 5540007<br />
640 160-4 4,0 8,0 5540008<br />
800 160-5 5,0 10,0 5540009<br />
960 160-6 6,0 12,0 5540010<br />
Cat. No.<br />
LDTS<br />
60 80/0.8 0,8 1,5 5531502<br />
105 80/1.3 1,3 2,6 5531504<br />
180 80/2.3 2,3 4,5 5531506<br />
220 80/2.8 2,8 5,5 5531508<br />
290 80/3.6 3,6 7,2 5531510<br />
410 80/5.1 5,1 10,2 5531512<br />
460 80/5.8 5,8 11,5 5531514<br />
560 80/7.0 7,0 14,0 5531516<br />
820 80/10.3 10,3 20,5 5531518<br />
1000 80/12.5 12,5 25,0 5531520<br />
1200 80/15.0 15,0 30,0 5531522<br />
1800 80/22.5 22,5 45,0 5531524<br />
ULTRA THIN CM MATS – a very thin two<br />
conductor cable with a protective screen –<br />
suitable for damp areas (bathrooms, laundry<br />
rooms) as well as for standard rooms – ideal<br />
for placement into adhesive sealing cement<br />
directly under floor tiling; Ø of cable<br />
2.4–2.7 mm, cold lead – 1×2.5 m.<br />
CM 150 W/m 2<br />
OUTPUT<br />
[W]<br />
Type<br />
Surface<br />
[m 2 ]<br />
Length<br />
[m]<br />
Cat. No.<br />
150 CM150/1 1,0 2,0 5540103<br />
225 CM150/1,5 1,5 3,0 5540105<br />
300 CM150/2 2,0 4,0 5540107<br />
375 CM150/2,5 2,5 5,0 5540109<br />
450 CM150/3 3,0 6,0 5540111<br />
600 CM150/4 4,0 8,0 5540113<br />
750 CM150/5 5,0 10,0 5540115
ECOFLOOR HEATING CABLE CIRCUITS<br />
ADSV heating cable, a twin conductor cable with a full protection screen suitable for wet areas.<br />
For direct fl oor heating or fl oor renovating (installation under tiles).<br />
Cable diameter 3.6–4.6 mm.<br />
Cold tail 1×3 m.<br />
Cables on drums Heating circuits<br />
TYPE<br />
(Ohm/m)<br />
Cat. No.<br />
122,5 2001510<br />
38,72 2001515<br />
14,020 2001520<br />
8,960 2001525<br />
5,232 2001530<br />
3,584 2001535<br />
2,568 2001540<br />
2,050 2001545<br />
1,382 2001550<br />
0,926 2001555<br />
0,638 2001560<br />
0,424 2001565<br />
0,310 2001570<br />
0,196 2001575<br />
0,136 2001580<br />
Cables on drums<br />
TYPE<br />
(Ohm/m)<br />
Cat. No.<br />
61,25 2005178<br />
27,13 2005179<br />
19,36 2005180<br />
7,010 2005181<br />
4,480 2005182<br />
2,616 2005183<br />
1,284 2005185<br />
0,857 2005187<br />
0,691 2005188<br />
0,463 2005190<br />
0,212 2005192<br />
0,155 2005193<br />
0,068 2005195<br />
OUTPUT<br />
[W]<br />
Type ADSV<br />
10 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
65 10065 6,6 2232100<br />
120 10120 11,4 2232105<br />
200 10200 18,9 2232110<br />
250 10250 23,6 2232115<br />
320 10320 31,6 2232120<br />
400 10400 36,9 2232125<br />
450 10450 45,9 2232130<br />
520 10520 49,6 2232135<br />
600 10600 63,9 2232140<br />
750 10750 75,8 2232145<br />
950 10950 87,0 2232150<br />
1100 101100 114,5 2232155<br />
1300 101300 131,3 2232160<br />
1700 101700 158,5 2232165<br />
2000 102000 194,5 2232170<br />
Heating circuits<br />
OUTPUT<br />
[W]<br />
Cable on drum Cable circuit on carton reel.<br />
standard packing.<br />
Type ASL1P<br />
10 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
160 10160 17,0 2200160<br />
280 10280 27,0 2200280<br />
350 10350 33,7 2200350<br />
450 10450 45,0 2200450<br />
640 10640 64,0 2200640<br />
800 10800 77,2 2200800<br />
960 10960 80,0 2200960<br />
1100 101100 103,9 2201100<br />
1600 101600 156,0 2201600<br />
1900 101900 179,6 2201900<br />
3000 103000 259,3 2203000<br />
OUTPUT<br />
[W]<br />
16<br />
Type ADSV<br />
15 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
80 15080 5,4 2242405<br />
140 15140 9,8 2242407<br />
240 15240 15,7 2242410<br />
300 15300 19,7 2242415<br />
400 15400 25,3 2242420<br />
470 15470 31,4 2242425<br />
550 15550 37,4 2242430<br />
630 15630 41 2242435<br />
750 15750 51,1 2242440<br />
950 15950 59,9 2242445<br />
1100 151100 75,1 2242450<br />
1350 151350 93,3 2242455<br />
1600 151600 106,7 2242460<br />
2400 152400 162,1 2242465<br />
ASL1P heating cable, a single-conductor cable with a full protection screen suitable for wet areas.<br />
For direct fl oor heating (installation under tiles).<br />
Cold lead 2×5 m. Cable diameter 2.9–3.6 mm. Packing in PE foil.<br />
OUTPUT<br />
[W]<br />
Type ASL1P<br />
15 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
200 15200 13,7 2201000<br />
340 15340 22,2 2201005<br />
420 15420 28,1 2201010<br />
550 15550 36,8 2201015<br />
800 15800 51,5 2201020<br />
960 15960 64,3 2201025<br />
1070 151070 71,5 2201030<br />
1300 151300 87,9 2201035<br />
1900 151900 131,3 2201040<br />
2200 152200 155,1 2201045<br />
3400 153400 228,8 2201055<br />
ECOFLOOR Installation – Heating Cable Circuit<br />
1) Create loops of the heating cable across the entire base (a spacing guide may be used, as shown).<br />
2) Fix the cable to the base using the self-adhesive tape or GRUFAST fastening strips.<br />
3) Level the layer of fl exible cement with a smooth trowel.<br />
4) Lay tiling on small areas (up to 4 m 2 ) immediately, and on larger areas after 24 hours.<br />
OUTPUT<br />
[W]<br />
Type ADSV<br />
18 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
160 18160 8,50 2243120<br />
260 18260 14,50 2243125<br />
320 18320 18,50 2243130<br />
420 18420 24,00 2243135<br />
520 18520 28,40 2243140<br />
600 18600 34,4 2243145<br />
680 18680 37,9 2243150<br />
830 18830 46,1 2243155<br />
1000 181000 57,5 2243160<br />
1200 181200 68,9 2243165<br />
1500 181500 83,2 2243170<br />
1700 181700 100,4 2243175<br />
2200 182200 122,7 2243180<br />
2600 182600 149,6 2243185<br />
OUTPUT<br />
[W]<br />
Type ASL1P<br />
18 W/m<br />
Packing in carton<br />
box available<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
210 18210 11,9 2201060<br />
350 18350 19,7 2201062<br />
450 18450 24 2201064<br />
570 18570 32,5 2201066<br />
820 18820 46 2201068<br />
1000 181000 56,5 2201070<br />
1100 181100 63,7 2201072<br />
1400 181400 74,7 2201074<br />
2000 182000 114,2 2201076<br />
2400 182400 130,1 2201078<br />
3000 183000 164,6 2201080<br />
3500 183500 203,4 2201082
KITS FOR DO-IT-YOURSELF INSTALLATION<br />
Kits for do-it-yourself installation have been designed for those users who do not want a complete electrical heating system but a comfortable,<br />
warm fl oor in a specifi c area (e.g. bathroom or kitchen). The kits include everything needed to install the fl oor heating system and are very<br />
reasonably priced. They are sold in two variants:<br />
ECOFLOOR CableKit<br />
OUTPUT<br />
[W]<br />
Type CK<br />
(10 W/m)<br />
AREA [m 2 ]<br />
160 W/m 2<br />
AREA [m 2 ]<br />
130 W/m 2<br />
AREA [m 2 ]<br />
100 W/m 2<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
65 10065 0,4 0,5 0,65 6,6 2360094<br />
120 10120 0,75 0,95 1,2 11,4 2360097<br />
200 10200 1,25 1,6 2,0 18,9 2360100<br />
250 10250 1,6 2,0 2,5 23,6 2360102<br />
320 10320 2,0 2,6 3,2 31,6 2360104<br />
400 10400 2,5 3,2 4,0 36,9 2360106<br />
450 10450 2,8 3,6 4,5 45,9 2360108<br />
520 10520 3,25 4,0 5,2 49,6 2360109<br />
600 10600 3,75 4,8 6,0 63,9 2360110<br />
750 10750 4,7 6,1 7,5 75,8 2360112<br />
950 10950 5,9 7,7 9,5 87,0 2360114<br />
1100 101100 6,9 8,9 11,0 114,5 2360116<br />
1300 101300 8,1 10,5 13,0 131,3 2360118<br />
1700 101700 10,6 13,1 17,0 158,8 2360119<br />
2000 102000 12,5 16,2 20,0 194,5 2360120<br />
Cable kit includes<br />
heating cable ADSV on carton reel<br />
thermostat Fenix Therm 100 with fl oor sensor<br />
protection tube for fl oor sensor<br />
adhesive fi xing tape<br />
template to plane cable runs for 100 W/m 2 ,<br />
130 W/m 2 and 160 W/m 2<br />
installation manual<br />
17<br />
ECOFLOOR ComfortMat<br />
OUTPUT<br />
[W]<br />
Type CM<br />
160 W/m 2<br />
AREA<br />
[m 2 ]<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
70 12070-165 0,5 0,9 5590094<br />
130 12130-165 0,8 1,6 5590097<br />
210 12210-165 1,3 2,6 5590100<br />
260 12260-165 1,6 3,2 5590105<br />
340 12340-165 2,1 4,2 5590110<br />
410 12410-165 2,6 5,2 5590115<br />
500 12500-165 3,0 6,1 5590120<br />
560 12560-165 3,4 6,7 5590122<br />
670 12670-165 4,2 8,3 5590125<br />
810 12810-165 5,1 10,2 5590130<br />
1000 121000-165 6,1 12,3 5590135<br />
1210 121210-165 7,6 15,1 5590140<br />
1400 121400-165 8,8 17,6 5590145<br />
OUTPUT<br />
[W]<br />
Type CM<br />
100 W/m 2<br />
AREA<br />
[m 2 ]<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
180 8180-105 1,9 3,6 5590148<br />
220 8220-105 2,2 4,4 5590150<br />
290 8290-105 2,9 5,8 5590152<br />
410 8410-105 4,1 8,2 5590155<br />
460 8460-105 4,7 9,4 5590157<br />
560 8560-105 5,6 11,2 5590160<br />
820 8820-105 8,2 16,5 5590165<br />
Width of the heating mat is 50 cm<br />
Comfort mat includes<br />
heating mat LDTS<br />
digital touch screen thermostat TFT<br />
protection tube for fl oor sensor<br />
installation manual<br />
It is recommended that you install F-Board insulated tile backer<br />
board before laying CK or CM. This will ensure quicker warm up<br />
times and reduce running costs (see page 25).
SEMI-STORAGE AND STORAGE HEATING<br />
ECOFLOOR CABLES AND MATS<br />
Heating cables or mats in semi-storage systems are placed<br />
in a layer of concrete 4–5 cm thick. The mat’s recommended<br />
output wattage is 160 W/m 2 . Heat is accumulated for 16<br />
hours a day at a time when electricity costs are lowest. The<br />
accumulated heat is radiated from the fl oor surface not<br />
only during the process, but also for a further 8 hours. One<br />
effi cient solution is to divide the total desired heating system<br />
70/30 between the fl oor heating and another source, such<br />
as a convection heater or an ECOSUN radiant panel.<br />
SEMI-STORAGE SYSTEM<br />
1 wear layer (fl oor tiling, carpet, PVC, laminate)<br />
2 fl oor (limitation) probe in a protective tube (so-called goose neck)<br />
3 load-bearing concrete fl oating board<br />
4 steel reinforcement (so-called Kari mesh)<br />
5 ECoFLooR ® heating mat (cable)<br />
6 thermal insulation<br />
7 base (concrete board)<br />
18<br />
Storage fl oor heating is a system that takes advantage of<br />
cheaper electricity tariffs – usually at night. During this time,<br />
heat is accumulated into the mass of the fl oor using ECOFLOOR<br />
electrical heating cables or mats. Throughout the rest of the<br />
day, the heat is gradually released from the fl oor to the room.<br />
In storage systems, heating mats or cables are placed in a layer<br />
of concrete 10 to 14 cm thick. The accumulated—stored—heat<br />
is then released during the day into the area to be heated.<br />
We recommend an output wattage of 250 to 300 W/m 2 for<br />
ECOFLOOR mats used in this type of system. Eight hours of<br />
low-tariff electricity should be used to accumulate the heat.<br />
STORAGE ECOFLOOR HEATING<br />
1 wear layer (fl oor tiles, carpet, PVC, laminate)<br />
2 fl oor (limitation) probe in a protective tube (so-called goose neck)<br />
3 concrete storage layer<br />
4 ECoFLooR ® heating mat (cable)<br />
5 concrete storage layer<br />
6 steel reinforcement (so-called Kari mesh)<br />
7 thermal insulation<br />
8 base (concrete board)
ADSV+ heating cable, a two-conductor cable with a full protection<br />
screen. The sheathing of the cable is resistant against<br />
UV radiation and is intended for fl oor heating and<br />
the removal of snow and ice from roofs and eaves<br />
troughs. 1×3 m cold lead. Ø 5.0 mm.<br />
Heating circuits<br />
OUTPUT<br />
[W]<br />
Type ADSV+<br />
10 W/m<br />
PSV heating cable, a single-conductor cable with a full protection screen for<br />
storage and semi-storage heating.<br />
Cables on drums<br />
TYPE<br />
Cat. No.<br />
(Ohm/m)<br />
19,36 2001210<br />
7,01 2001215<br />
4,48 2001220<br />
2,616 2001225<br />
1,792 2001230<br />
1,284 2001235<br />
1,025 2001240<br />
0,857 2001245<br />
0,691 2001250<br />
0,54 2001255<br />
0,463 2001260<br />
0,319 2001265<br />
0,212 2001270<br />
0,155 2001275<br />
0,098 2001280<br />
0,068 2001285<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
120 10120 11,4 2253000<br />
200 10200 18,9 2253005<br />
250 10250 23,6 2253010<br />
320 10320 31,6 2253015<br />
400 10400 36,9 2253020<br />
450 10450 45,9 2253025<br />
520 10520 49,6 2253030<br />
600 10600 63,9 2253035<br />
750 10750 75,8 2253040<br />
950 10950 87,0 2253045<br />
1100 101100 114,5 2253050<br />
1300 101300 131,3 2253055<br />
1700 101700 158,5 2253060<br />
2000 102000 194,5 2253065<br />
Cold lead 2×5 m. Cable diameter 4.5–5.1 mm.<br />
Heating circuits<br />
OUTPUT Type PSV LENGTH<br />
[W] 10 W/m [m]<br />
Cat. No.<br />
OUTPUT Type PSV<br />
[W] 15 W/m<br />
170 10170 16,1 2320020<br />
280 10280 28,0 2320025<br />
350 10350 34,0 2320030<br />
450 10450 46,0 2320035<br />
550 10550 53,7 2320040<br />
640 10640 64,4 2320045<br />
720 10720 71,7 2320050<br />
800 10800 79,1 2320055<br />
870 10870 88,0 2320060<br />
960 10960 100,0 2320065<br />
1100 101100 106,8 2320070<br />
1280 101280 129,6 2320075<br />
1600 101600 157,9 2320080<br />
1900 101900 189,6 2320085<br />
2500 102500 234,7 2320090<br />
3000 103000 277,8 2320095<br />
PSV cable circuit<br />
a single-conductor cable<br />
with 2×5 m cold leads.<br />
Packing in carton box.<br />
OUTPUT<br />
[W]<br />
Type ADSV+<br />
18 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
160 18160 8,5 2253100<br />
260 18260 14,5 2253105<br />
320 18320 18,5 2253110<br />
420 18420 24,0 2253115<br />
520 18520 28,4 2253120<br />
600 18600 34,4 2253125<br />
680 18680 37,9 2253130<br />
830 18830 46,1 2253135<br />
1000 181000 57,5 2253140<br />
1200 181200 68,9 2253145<br />
1500 181500 83,2 2253150<br />
1700 181700 100,4 2253155<br />
2200 182200 122,7 2253160<br />
2600 182600 149,6 2253165<br />
LENGTH<br />
[m]<br />
19<br />
OUTPUT<br />
[W]<br />
Cat. No.<br />
200 15200 13,7 2320110<br />
340 15340 22,2 2320115<br />
420 15420 28,1 2320120<br />
550 15550 36,7 2320125<br />
660 15660 44,7 2320130<br />
800 15800 52,3 2320135<br />
880 15880 58,6 2320140<br />
960 15960 64,1 2320145<br />
1070 151070 71,5 2320150<br />
1210 151210 81,0 2320155<br />
1300 151300 84,1 2320160<br />
1580 151580 104,6 2320165<br />
1900 151900 128,6 2320170<br />
2200 152200 150,3 2320175<br />
2800 152800 189,4 2320180<br />
3400 153400 227,5 2320185<br />
ADPSV heating cable, a twin conductor cable with a full protection<br />
screen is suitable for semi-storage<br />
and storage fl oor heating in living areas.<br />
Class M2. Cold lead 1×5 m. Ø 5.0–<br />
5.9 mm.<br />
Type ADPSV<br />
18 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
160 18160 8,5 2249960<br />
260 18260 14,5 2249963<br />
320 18320 18,5 2249966<br />
420 18420 24,0 2249969<br />
520 18520 28,4 2249972<br />
600 18600 34,4 2249975<br />
740 18740 41,8 2249976<br />
830 18830 46,1 2249978<br />
1000 181000 57,5 2249981<br />
1200 181200 68,9 2249984<br />
1500 181500 83,2 2249987<br />
1700 181700 100,4 2249990<br />
2200 182200 122,7 2249992<br />
2600 182600 149,6 2249993<br />
ADPSV cable circuit<br />
a twin conductor cable<br />
ADsV+, ADPsV packing<br />
LPSV heating mat, single conductor cable with a<br />
full protection screen, width<br />
50 cm, cold lead 2×5 m.<br />
Packed on a cardboard tube<br />
and sealed in PE foil.<br />
OUTPUT<br />
[W]<br />
Type LPSV<br />
100 W/m 2<br />
Surface<br />
[m 2 ]<br />
Length<br />
[m]<br />
Cat. No.<br />
180 LPSV 1,8 1,8 3,6 5520352<br />
300 LPSV 3 3,0 6,0 5520354<br />
370 LPSV 3, 3,7 7,4 5520356<br />
480 LPSV 3,7 4,8 9,6 5520358<br />
580 LPSV 5,8 5,8 11,6 5520360<br />
700 LPSV 7 7,0 14,0 5520362<br />
770 LPSV 7,7 7,7 15,4 5520364<br />
850 LPSV 8,5 8,5 17,0 5520366<br />
940 LPSV 9,4 9,4 18,8 5520368<br />
1050 LPSV 10,5 10,5 21,0 5520370<br />
1150 LPSV11,5 11,5 23,0 5520372<br />
1400 LPSV 14 14,0 28,0 5520374<br />
1700 LPSV 17 17,0 34,0 5520376<br />
2000 LPSV 20 20,0 40,0 5520378<br />
2500 LPSV 25 25,0 50,0 5520380<br />
Packing in carton<br />
box available
OUTDOOR APPLICATIONS<br />
Ice and snow melting<br />
Installing electric heating cables in outdoor areas,<br />
together with a thermostat, prevents both ice formation<br />
and snow accumulation. Once installed, the system works<br />
entirely automatically and is only operational when it is<br />
snowing or if ice is forming on roads and walkways.<br />
De-icing gutters and eaves troughs<br />
In all parts of Europe other than in the south, winter brings<br />
a heavy load to many buildings as ice builds up in the<br />
gutters and eaves troughs. Installing an ECOFLOOR<br />
electric heating cable (with a protective screen) into<br />
gutters and eaves troughs is a good solution for such<br />
problems. The cables are installed using special plastic clips<br />
placed inside gutters and eaves troughs. We recommend<br />
a linear wattage of 20 W/m for the de-icing cables.<br />
Frost protection of pipes<br />
Many homeowners and other users of piping have<br />
many troubles in the winter due to freezing pipes.<br />
This especially applies to pipes for water piping, but<br />
other liquids used in industrial technologies can also<br />
freeze or solidify. During long spells of below-freezing<br />
temperatures, even very well-insulated piping can freeze.<br />
Supplementary heating is a reliable preventive solution.<br />
20
MAPSV heating cable, a single-conductor cable with a full protection<br />
screen and protection against UV radiation. Suitable for heating<br />
outdoor surfaces. Cold lead 2×5 m. Ø 5.0–5.5 mm.<br />
Cables on drums Heating circuits<br />
TYPE<br />
(Ohm/m)<br />
Cat. No.<br />
9,00 2000850<br />
6,50 2000852<br />
3,20 2000854<br />
1,35 2000856<br />
1,00 2000858<br />
0,60 2000860<br />
0,36 2000862<br />
0,25 2000864<br />
0,183 2000866<br />
0,155 2000868<br />
0,098 2000870<br />
0,068 2000872<br />
0,04 2000874<br />
MAPSV cables 400 V<br />
OUTPUT Type MAPSV<br />
[W] 20 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
340 20340 17,3 2322500<br />
400 20400 20,3 2322502<br />
570 20570 29,0 2322504<br />
880 20880 44,5 2322506<br />
1030 201030 51,4 2322508<br />
1350 201350 65,3 2322510<br />
1750 201750 84,0 2322512<br />
2100 202100 100,8 2322514<br />
2400 202400 120,4 2322516<br />
2600 202600 131,3 2322518<br />
3300 203300 163,6 2322520<br />
4000 204000 194,5 2322522<br />
5100 205100 259,3 2322524<br />
OUTPUT<br />
[W]<br />
Type MAPSV<br />
20 W/m – 400 V<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
600 20600 29,6 2322650<br />
700 20700 35,2 2322652<br />
1000 201000 50,0 2322654<br />
1550 201550 76,5 2322656<br />
1800 201800 88,9 2322658<br />
2300 202300 115,9 2322660<br />
3000 203000 148,1 2322662<br />
3500 203500 182,9 2322664<br />
4200 204200 208,2 2322666<br />
4600 204600 224,4 2322668<br />
5800 205800 281,5 2322670<br />
7000 207000 336,1 2322672<br />
9000 209000 444,4 2322674<br />
MST mats, 230 V, width 0,5 m<br />
OUTPUT<br />
[W]<br />
Type MST<br />
300 W/m2 AREA<br />
[m2 ]<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
450 23MST 300/1,5-0,5 1,5 3,0 5501100<br />
600 23MST 300/2-0,5 2,0 4,0 5501105<br />
900 23MST 300/3-0,5 3,0 6,0 5501110<br />
1200 23MST 300/4-0,5 4,0 8,0 5501115<br />
1500 23MST 300/5-0,5 5,0 10,0 5501120<br />
1800 23MST 300/6-0,5 6,0 12,0 5501125<br />
2100 23MST 300/7-0,5 7,0 14,0 5501130<br />
2400 23MST 300/8-0,5 8,0 16,0 5501132<br />
2700 23MST 300/9-0,5 9,0 18,0 5501135<br />
3000 23MST 300/10-0,5 10,0 20,0 5501140<br />
3600 23MST 300/12-0,5 12,0 24,0 5501145<br />
4500 23MST 300/15-0,5 15,0 30,0 5501150<br />
6000 23MST 300/20-0,5 20,0 40,0 5501155<br />
30 W/m for removing ice and snow from roofs and gutters.<br />
Must be used control system with air temperature and moisture sensor<br />
protecting cables to switch-on in temperature more than +5 °C.<br />
OUTPUT Type MAPSV<br />
[W] 25 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
380 25380 15,5 2322550<br />
450 25450 18,1 2322552<br />
640 25640 25,8 2322554<br />
990 25990 40,0 2322556<br />
1150 251150 46,0 2322558<br />
1480 251480 59,6 2322560<br />
1900 251900 77,3 2322562<br />
2300 252300 92,0 2322564<br />
2700 252700 107,1 2322566<br />
2900 252900 117,1 2322568<br />
3700 253700 145,9 2322570<br />
4400 254400 176,8 2322572<br />
5700 255700 232,0 2322574<br />
OUTPUT<br />
[W]<br />
Type MAPSV<br />
30 W/m – 400 V<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
730 30730 24,4 2322700<br />
850 30850 29,0 2322702<br />
1230 301230 40,7 2322704<br />
1900 301900 62,4 2322706<br />
2200 302200 72,7 2322708<br />
2800 302800 95,2 2322710<br />
3700 303700 120,1 2322712<br />
4400 304400 145,5 2322714<br />
5100 305100 171,4 2322716<br />
5600 305600 184,3 2322718<br />
7000 307000 233,2 2322720<br />
8500 308500 276,8 2322722<br />
11000 3011000 363,6 2322724<br />
MST mats, 400 V, width 0,5 m<br />
OUTPUT<br />
[W]<br />
Type MST<br />
300 W/m2 AREA<br />
[m2 ]<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
900 40MST 300/3-0,5 3,0 6,0 5501300<br />
1200 40MST 300/4-0,5 4,0 8,0 5501305<br />
1800 40MST 300/6-0,5 6,0 12,0 5501310<br />
2100 40MST 300/7-0,5 7,0 14,0 5501315<br />
2700 40MST 300/9-0,5 9,0 18,0 5501320<br />
3600 40MST 300/12-0,5 12,0 24,0 5501325<br />
4200 40MST 300/14-0,5 14,0 28,0 5501330<br />
4800 40MST 300/16-0,5 16,0 32,0 5501335<br />
5400 40MST 300/18-0,5 18,0 36,0 5501340<br />
6600 40MST 300/22-0,5 22,0 44,0 5501345<br />
21<br />
TYPE Suitability Max. loading<br />
Floor heating in living areas Yes 30 W/m<br />
Outdoor surface heating Yes 30 W/m<br />
Frost protection of pipes Yes 15 W/m<br />
Pipe heating Yes 15 W/m<br />
Removing ice and snow from roofs and gutters Yes 30 W/m<br />
OUTPUT Type MAPSV<br />
[W] 30 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
420 30420 14,0 2322600<br />
500 30500 16,3 2322602<br />
700 30700 23,6 2322604<br />
1100 301100 35,6 2322606<br />
1250 301250 42,3 2322608<br />
1600 301600 55,1 2322610<br />
2100 302100 70,0 2322612<br />
2500 302500 84,6 2322614<br />
2950 302950 98,0 2322616<br />
3200 303200 106,7 2322618<br />
4000 304000 134,9 2322620<br />
4800 304800 162,1 2322622<br />
6300 306300 209,9 2322624<br />
Mats MST available also in 1m width. For easy installation the heating mat MST is provided with 1×5 m cold lead and with other<br />
cold lead 1×5 m + lenght of the mat. Cables and mats are packing in PE foil.<br />
DRIVEWAY<br />
1 hardened surface, e.g. interlocking pavement<br />
2 humidity sensor (water, snow, ice)<br />
3 sand bed of the interlocking pavement<br />
4 concrete board (protects the heating cable from vehicle load)<br />
5 ECoFLooR ® MAPsV/MADPsP heating cable or MsT/MDT mat<br />
6 fi rm gravel base (macadam)<br />
PAVEMENT<br />
1 hardened surface, e.g. fl oor tiling<br />
2 humidity sensor (water, snow, ice)<br />
3 sand fi ll and the sub-base of the cable<br />
4 ECoFLooR ® MAPsV/MADPsP heating cable or MsT/MDT mat<br />
5 fi rm gravel base (macadam)
MADPSP heating cable, a two-conductor cable with a full protection<br />
screen and protection against UV radiation. Suitable for heating<br />
outdoor surfaces. Class M2. Cold lead 1×5 m. Ø 6.2–8.9 mm.<br />
Cables on dr. Heating circuits<br />
TYPE<br />
Cat. No.<br />
(Ohm/m)<br />
18,00 2000700<br />
6,40 2000705<br />
2,70 2000710<br />
2,00 2000715<br />
1,20 2000720<br />
0,72 2000725<br />
0,60 2000730<br />
0,36 2000735<br />
0,25 2000737<br />
0,18 2000740<br />
0,08 2000745<br />
0,04 2000750<br />
MADPSP cable, 400 V<br />
OUTPUT<br />
[W]<br />
MADPSP<br />
20 W/m<br />
400 V<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
420 20420 21,2 2323403<br />
700 20700 35,7 2323406<br />
1100 201100 53,9 2323409<br />
1250 201250 64,0 2323412<br />
1600 201600 83,3 2323415<br />
2100 202100 105,8 2323418<br />
2300 202300 113,7 2323421<br />
3000 203000 143,5 2323424<br />
3600 203600 168,7 2323425<br />
4200 204200 202,2 2323427<br />
6300 206300 317,5 2323430<br />
OUTPUT<br />
[W]<br />
Cables and mats are packing in PE foil.<br />
PFP – automatic heating<br />
cable with a thermostat, electrical<br />
socket connection, the thermostat<br />
switches on at +3 °C, 1,5 m connection<br />
cable with plug, IP 66<br />
coverage.<br />
OUTPUT<br />
[W]<br />
30 W/m (35 W/m for removing ice and snow from roofs and<br />
gutters. Must be used control system with air temperature and moisture<br />
sensor protecting cables to switch-on in temperature more than +5 °C).<br />
OUTPUT MADPSP LENGTH<br />
[W] 15 W/m [m]<br />
Cat. No.<br />
210 15210 14,0 2323153<br />
350 15350 23,6 2323156<br />
540 15540 36,3 2323159<br />
630 15630 42,0 2323162<br />
810 15810 54,4 2323165<br />
1050 151050 70,0 2323168<br />
1150 151150 75,2 2323171<br />
1500 151500 95,0 2323174<br />
1800 151800 111,3 2323175<br />
2100 152100 133,7 2323177<br />
3150 153150 209,9 2323180<br />
4500 154500 255,7 2323183<br />
MADPSP<br />
30 W/m<br />
400 V<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
520 30520 17,1 2323453<br />
860 30860 29,1 2323456<br />
1330 301330 44,6 2323459<br />
1550 301550 51,6 2323462<br />
2000 302000 66,7 2323465<br />
2600 302600 85,5 2323468<br />
2800 302800 93,4 2323471<br />
3600 303600 119,8 2323474<br />
4500 304500 134,9 2323475<br />
5100 305100 166,7 2323477<br />
7700 307700 259,7 2323480<br />
Type PFP<br />
OUTPUT MADPSP LENGTH<br />
[W] 20 W/m [m]<br />
Cat. No.<br />
240 20240 12,2 2323203<br />
400 20400 20,7 2323206<br />
630 20630 31,1 2323209<br />
730 20730 36,2 2323212<br />
950 20950 46,4 2323215<br />
1200 201200 61,2 2323218<br />
1300 201300 66,5 2323221<br />
1700 201700 83,7 2323224<br />
2000 202000 100,2 2323225<br />
2400 202400 117,0 2323227<br />
3600 203600 183,7 2323230<br />
5100 205100 227,6 2323233<br />
LENGTH<br />
[m]<br />
MDT mat, 230 V, width 0,5 m MDT mat, 400 V, width 0,5 m<br />
OUTPUT<br />
[W]<br />
MDT<br />
300 W/m 2<br />
22<br />
OUTPUT MADPSP LENGTH<br />
[W] 25 W/m [m]<br />
Cat. No.<br />
270 25270 10,9 2323253<br />
450 25450 18,4 2323256<br />
700 25700 28,0 2323259<br />
800 25800 33,1 2323262<br />
1050 251050 42,0 2323265<br />
1350 251350 54,4 2323268<br />
1480 251480 58,5 2323271<br />
1900 251900 74,8 2323274<br />
2300 252300 87,2 2323275<br />
2700 252700 103,9 2323277<br />
4000 254000 165,3 2323280<br />
5700 255700 203,5 2323283<br />
AREA<br />
[m 2 ]<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
270 23MDT300/0,9–0,5 0,9 1,8 5500100<br />
450 23MDT300/1,5–0,5 1,5 3,0 5500105<br />
700 23MDT300/2,3–0,5 2,3 4,6 5500110<br />
800 23MDT300/2,7–0,5 2,7 5,4 5500115<br />
1050 23MDT300/3,5–0,5 3,5 7,0 5500120<br />
1350 23MDT300/4,5–0,5 4,5 9,0 5500125<br />
1480 23MDT300/5–0,5 5,0 10,0 5500130<br />
1900 23MDT300/6,3–0,5 6,3 12,6 5500135<br />
2300 23MDT300/7,8–0,5 7,8 15,6 5500140<br />
4000 23MDT300/13,3–0,5 13,3 26,6 5500145<br />
Cat. No.<br />
12 PFP 1m/12W 1 2330150<br />
25 PFP 2m/25W 2 2330152<br />
36 PFP 3m/36W 3 2330154<br />
48 PFP 4m/48W 4 2330156<br />
72 PFP 6m/72W 6 2330158<br />
136 PFP 10m/136W 10 2330160<br />
152 PFP 14m/152W 14 2330162<br />
281 PFP 21m/281W 21 2330164<br />
337 PFP 30m/337W 30 2330166<br />
490 PFP 42m/490W 42 2330168<br />
TYPE Suitability Max. loading<br />
Floor heating in living areas Yes 20 W/m<br />
Outdoor surface heating Yes 30 W/m<br />
Frost protection of pipes Yes 15 W/m<br />
Pipe heating Yes 15 W/m<br />
Removing ice and snow from roofs and gutters Yes 35 W/m<br />
OUTPUT<br />
[W]<br />
OUTPUT MADPSP LENGTH<br />
[W] 30 W/m [m]<br />
Cat. No.<br />
300 30300 9,8 2323303<br />
500 30500 16,5 2323306<br />
760 30760 25,8 2323309<br />
880 30880 30,1 2323312<br />
1150 301150 38,3 2323315<br />
1500 301500 49,0 2323318<br />
1600 301600 54,1 2323321<br />
2100 302100 67,8 2323324<br />
2500 302500 80,5 2323325<br />
3000 303000 93,5 2323327<br />
4400 304400 150,3 2323330<br />
6300 306300 183,7 2323333<br />
MDT<br />
300 W/m 2<br />
AREA<br />
[m 2 ]<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
520 40MDT300/1,8–0,5 1,8 3,6 5500200<br />
860 40MDT300/2,9–0,5 2,9 5,8 5500205<br />
1330 40MDT300/4,5–0,5 4,5 9,0 5500210<br />
1550 40MDT300/5,2–0,5 5,2 10,4 5500215<br />
2000 40MDT300/6,7–0,5 6,7 13,4 5500220<br />
2600 40MDT300/8,7–0,5 8,7 17,4 5500225<br />
2800 40MDT300/9,3–0,5 9,3 18,6 5500230<br />
3600 40MDT300/12–0,5 12,0 24,0 5500235<br />
4500 40MDT300/15–0,5 15,0 30,0 5500240<br />
7700 40MDT300/25,7–0,5 25,7 51,4 5500245<br />
The heating mat MDT is provided<br />
with 1×5 m cold lead<br />
FOOTBALL PITCH<br />
1 grass<br />
2 soil layer, approx. 30 cm thick<br />
3 sand bedding, approx. 7 cm (compacted) and approx. 3 cm thick fi ll<br />
4 ECoFLooR ® MAPsV/MADPsP heating cable or MsT/MDT mat<br />
(approx. 20 W/m, 100 W/m 2 , cable loop spacing 20 cm)<br />
5 Levelled solid base (grown, soil)
ADSV+ heating cable, a two-conductor cable with a full protection<br />
screen. The sheathing of the cable is resistant<br />
against UV radiation and is intended for fl oor<br />
heating and the removal of snow and ice from<br />
roofs and eaves troughs. 1×3 m cold lead.<br />
Ø 5.0 mm.<br />
Heating circuits<br />
OUTPUT<br />
[W]<br />
Type ADSV+<br />
10 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
120 10120 11,4 2253000<br />
200 10200 18,9 2253005<br />
250 10250 23,6 2253010<br />
320 10320 31,6 2253015<br />
400 10400 36,9 2253020<br />
450 10450 45,9 2253025<br />
520 10520 49,6 2253030<br />
600 10600 63,9 2253035<br />
750 10750 75,8 2253040<br />
950 10950 87,0 2253045<br />
1100 101100 114,5 2253050<br />
1300 101300 131,3 2253055<br />
1700 101700 158,5 2253060<br />
2000 102000 194,5 2253065<br />
OUTPUT<br />
[W]<br />
Type ADSV+<br />
18 W/m<br />
ADPSV heating cable, a twin conductor, full protection screened<br />
cable with protection against UV radiation. This<br />
multipurpose cable is suitable for indoor and<br />
outdoor applications. Class M2. Cold lead<br />
1×5 m. Ø 5.0–5.9 mm.<br />
Cables on drums Heating circuits<br />
TYPE<br />
(Ohm/m)<br />
Cat. No.<br />
38,72 2000500<br />
14,02 2000505<br />
8,96 2000510<br />
5,232 2000515<br />
3,58 2000520<br />
2,568 2000525<br />
1,714 2000535<br />
1,382 2000540<br />
0,926 2000550<br />
0,638 2000555<br />
0,424 2000560<br />
0,31 2000565<br />
0,196 2000570<br />
0,136 2000575<br />
OUTPUT<br />
[W]<br />
Type ADPSV<br />
20 W/m<br />
LENGTH<br />
[m]<br />
23<br />
TYPE Suitability Max. loading<br />
Floor heating in living areas Yes 20 W/m<br />
Outdoor surface heating No –<br />
Frost protection of pipes Yes 10 W/m<br />
Pipe heating Yes 10 W/m<br />
Removing ice and snow from roofs and gutters Yes 20 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
160 18160 8,5 2253100<br />
260 18260 14,5 2253105<br />
320 18320 18,5 2253110<br />
420 18420 24,0 2253115<br />
520 18520 28,4 2253120<br />
600 18600 34,4 2253125<br />
680 18680 37,9 2253130<br />
830 18830 46,1 2253135<br />
1000 181000 57,5 2253140<br />
1200 181200 68,9 2253145<br />
1500 181500 83,2 2253150<br />
1700 181700 100,4 2253155<br />
2200 182200 122,7 2253160<br />
2600 182600 149,6 2253165<br />
Cat. No.<br />
160 20160 8,3 2252800<br />
270 20270 14,0 2252805<br />
340 20340 17,2 2252810<br />
450 20450 22,5 2252815<br />
540 20540 27,4 2252820<br />
640 20640 32,1 2252825<br />
780 20780 39,3 2252830<br />
870 20870 43,8 2252835<br />
1070 201070 53,5 2252840<br />
1290 201290 64,4 2252845<br />
1580 201580 79,0 2252850<br />
1850 201850 92,4 2252855<br />
2300 202300 117,3 2252865<br />
2750 202750 141,4 2252870<br />
OUTPUT<br />
[W]<br />
PDSP heating cable, a two-conductor cable with a full protection<br />
screen and protection against UV radiation. Suitable for heating<br />
outdoor surfaces. Class M2. Cold lead 1×5 m. Outer cable diameter<br />
– oval 4.5×7 mm.<br />
TYPE Suitability Max. loading<br />
Floor heating in living areas Yes 28 W/m<br />
Outdoor surface heating Yes 28 W/m<br />
Removing ice and snow from roofs and gutters Yes 28 W/m<br />
Heating circuits<br />
Must be used control system with air temperature and moisture sensor<br />
protecting cables to switch-on in temperature more than +5 °C.<br />
(Ohm/m)<br />
OUTPUT<br />
[W]<br />
PDSP<br />
28 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
3,58 640 15210 23,1 2323810<br />
2,05 890 15350 29 2323815<br />
0,93 1270 15540 44,8 2323820<br />
0,42 1900 15630 66,3 2323825<br />
0,196 2700 15810 100 2323830<br />
0,136 3400 151050 114,4 2323835<br />
OUTPUT<br />
[W]<br />
STAIRS<br />
1 wear layer (fl oor tiling)<br />
2 fl exible bonding cement<br />
3 ECoFLooR ® ADPsV/MAPsV/<br />
MADPsP/PDsP heating cable<br />
4 stairs<br />
Type ADSV+<br />
20 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
160 20160 8,3 2253200<br />
270 20270 14,0 2253205<br />
340 20340 17,2 2253210<br />
450 20450 22,5 2253215<br />
540 20540 27,4 2253220<br />
640 20640 32,1 2253225<br />
720 20720 35,8 2253230<br />
870 20870 43,8 2253235<br />
1070 201070 53,5 2253240<br />
1290 201290 64,4 2253245<br />
1580 201580 79,0 2253250<br />
1850 201850 92,4 2253255<br />
2300 202300 117,3 2253260<br />
2750 202750 141,4 2253265<br />
TYPE Suitability Max. loading<br />
Outdoor surface heating Yes 20 W/m<br />
Frost protection of pipes Yes 10 W/m<br />
Pipe heating Yes 10 W/m<br />
Removing ice and snow from roofs and gutters Yes 20 W/m<br />
Type ADPSV<br />
10 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
120 10120 11,4 2256010<br />
200 10200 18,9 2256015<br />
250 10250 23,6 2256020<br />
320 10320 31,6 2256025<br />
400 10400 36,9 2256030<br />
450 10450 45,9 2256035<br />
550 10550 56,1 2256040<br />
600 10600 63,9 2256045<br />
750 10750 75,8 2256050<br />
950 10950 87,0 2256055<br />
1100 101100 114,5 2256060<br />
1300 101300 131,3 2256065<br />
1700 101700 158,5 2256070<br />
2000 102000 194,5 2256075<br />
ADPsV cable.<br />
Packing on carton reel.
SPECIAL APPLICATIONS<br />
CONCRETE CURING CABLE CIRCUITS<br />
A twin conductor screened cable with a 1×2 m<br />
cold lead with plug connection. 230 V.<br />
OUTPUT<br />
[W]<br />
Type PDS1P<br />
40 W/m<br />
LENGTH<br />
[m]<br />
Cat. No.<br />
130 40130 3,3 2325000<br />
380 40380 10,0 2325005<br />
760 40760 19,0 2325010<br />
1400 401400 35,0 2325018<br />
1500 401500 38,0 2325020<br />
3300 403300 82,0 2325030<br />
PDS1P cable for curing<br />
concrete. Packing in PE foil.<br />
SELF-REGULATING CABLES<br />
The ELSR self-regulating cables are<br />
parallel electrical heating strips consisting<br />
of a specially fi nished plastic with<br />
embedded carbon particles that create<br />
an electrical path between two parallel<br />
copper bus bars.<br />
Marking<br />
Output W/m<br />
10°C<br />
Temperature<br />
tolerance [°C]<br />
Limitation for instalation<br />
Min. temp. Min. radius<br />
Max. length at the<br />
temperature setting<br />
Cat. No.<br />
ELSR-M – Frost protection of pipe 6 A 10 A 16 A<br />
ELSR-M – 10 BO 10 65 –30°C 35 mm 65 m 95 m 105 m 2330310<br />
ELSR-M – 15 BO 15 65 –30°C 35 mm 37 m 58 m 65 m 2330315<br />
ELSR-N – Frost protection of trays, gutters, roofs, technological heating 16 A 20 A 25 A<br />
ELSR-N – 20 BO 20 80 –10°C 20 mm 94 m 116 m 146 m 2330320<br />
ELSR-N – 30 BO 30 80 –10°C 20 mm 70 m 87 m 109 m 2330330<br />
KIT Nr. 4 For connection and termination of self-limiting cables 5030124<br />
Cold lead for self-regulating cables<br />
SK 1,5 Limitation: 12 A / 20 m 2000790<br />
SK 2,5 Limitation: 20 A / 20 m 2000795<br />
Industrial applications:<br />
Analyzer lines – prevent condensation<br />
Cooling water lines – anti-freeze protection<br />
Potable water lines – anti-freeze protection<br />
Caustic soda – prevent crystallization<br />
under 30 °C<br />
24<br />
Oils and fats – maintain pumpable viscosity<br />
Heating oil – prevent wax dispersion<br />
Vessel – anti-freeze and condensation<br />
protection<br />
PC / PC-S CABLES WITH CONSTANT LINEAR WATTAGE; PCC CIRCUITS<br />
Cables with constant linear wattage provide a constant wattage per standard metre which enables their shortening and fi nal alterations at the<br />
place of installation. They are suitable for applications where higher outputs and thermal resistance are required – the heating of insulation in<br />
freezers, pipe heating, process heating, heating of compressor drainage pipes, etc.<br />
The cable consists of two independently insulated supply conductors around which a very thin heating (resistance) wire is wound. It is connected to the supply conductors every 1 m of length<br />
– alternately to the phase and to the working conductor. In this way, ‘heating zones’ with a length of 1 m are created. To simplify – these are one-metre long resistance cables connected<br />
one after another in a coil. The whole structure is fi tted with a PC-S type silicon jacket, and also with a braided protective screen – termed armouring. The cable can be shortened to the<br />
required length; the wattage per 1 m remains the same, however. WARNING: the beginning and end of the cable will not give out heat; heating occurs from the following<br />
(preceding) heating zone! In an extreme<br />
Protective braiding<br />
Marking<br />
Output Operating Temperature Length of Min. order Max. length<br />
Cat. No.<br />
(armouring) [W/m] temperatures resistance heating zone length of circuit<br />
situation, if the cable is shortened immediately after<br />
PC 25 –<br />
the connection of the resistance wire to the conduc-<br />
25 −50…60 °C 180 °C tor, this non-heating part can be up to 1 m long – we<br />
therefore recommend that a minimum of 1 m<br />
of extra cable is ordered.<br />
1) 2330210<br />
1 m 2 m 80 m<br />
PC-S 25 CuSn (1 mm²) 2330212<br />
PC 50 –<br />
50 −50…60 °C 180 °C 1) 2330214<br />
1 m 2 m 70 m<br />
PC-S 50 CuSn (1 mm²) 2330216<br />
Operating voltage 230 V / 50 Hz, dielectric strength 1 500 V, cross sectional area of the conductors 2×0.75 mm² (for 25 W/m) and 2×1.5 mm² (for 50 W/m), heating (resistance)<br />
conductor Ni/Cr (80/20).<br />
PCC circuits are made from braided (armoured) cable with a constant linear wattage of 30 W/m – in principle, it is the same kind of cable as<br />
the PC-S type, but this is not sold per metre but only as fi nished<br />
circuits of set lengths, fi tted with a connecting lead (termed<br />
a cold lead) with a length of 1.5 m. Thanks to the silicon jacket<br />
and the thermal resistance, they are ideal for the protection of<br />
insulation for refrigeration equipment and freezers.<br />
1) Thermal resistance of the cable in a switched-off state<br />
THE D-MAT HEATING SHEET<br />
Is intended for outdoor use as anti-freeze protection in industrial applications and in the<br />
construction industry – for example, for<br />
the warming of the earth in excavation<br />
pits or of stored friable materials, the<br />
warming of cables on reels, maintenance<br />
of warmth in parts of<br />
machines or in tools, etc. The<br />
sheet is also suitable for<br />
use in extreme winter<br />
conditions. Technical<br />
parameters: IP 56<br />
coverage; heated<br />
area 1.2×2.85 m<br />
(3.4 m 2 ); total sheet dimensions 1.5×3.05 m; 5 m supply<br />
lead ends in a SCHUKO plug. 230 V / 50 Hz; 9,6 kg.<br />
Type<br />
Output<br />
[W]<br />
PCC 90/3 90<br />
Linear<br />
wattage<br />
Operating<br />
temperatures<br />
Temperature<br />
resistance<br />
OUTPUT<br />
[W]<br />
Type D-MAT<br />
280 W/m2 Cat. No.<br />
950 DM 3,4/280 5505000<br />
Length<br />
[m]<br />
Resistance<br />
[�]<br />
Cat. No.<br />
30 W/m −40…60 °C 180 °C 1)<br />
3,0 587,8 2330250<br />
PCC 150/5<br />
PCC 210/7<br />
150<br />
210<br />
5,0<br />
7,0<br />
352,7<br />
251,9<br />
2330252<br />
2330254<br />
PCC 300/10 300 10,0 176,3 2330256<br />
Operating voltage 230 V / 50 Hz, IP 67 coverage, cable diameter 4–4.4 mm; 1×cold lead 1.5 m
ECOFLOOR ACCESSORIES<br />
F-BOARD FLOOR INSULATION<br />
F-boards prevent heat losses to the subfl oor structure. Recommended for fl oor reconstructions.<br />
Type Dimensions [mm] Thickness [mm]<br />
Packaging<br />
[boards in packet]<br />
Packets on the<br />
pallet<br />
Cat. No.<br />
F-BOARD 6 1250×600×6 6 6 67 5442016<br />
F-BOARD10 1250×600×10 10 6 43 5442019<br />
Useful information<br />
Dimensions 600 mm × 1250 mm (0,75 m 2 each)<br />
Thickness 6 mm or 10 mm<br />
Weight (kg/board) 1,8 (6 mm) 2,0 (10 mm)<br />
Material<br />
Density 32 kg/m3 Thermal Conductivity 0,029 W/m°k<br />
Compresive strenght 300 kN/m2 Water absorption (immersion) < 1,5 % by vol<br />
Water absorption (capillary) Nil<br />
Co-effi cient of Linear Expansion 0,07 mm/mK<br />
Flamibility B1<br />
Extruded Polystyrene core with Polymer<br />
cement outer skin<br />
25<br />
Quantity supplied Cat. No.<br />
Gutter clip, 1 package = 25 pcs. Material: frost-resistant plastic. 1 package 2350000<br />
Gutter clip 150, 1 package = 25 pcs.<br />
Material: frost-resistant plastic, suitable for self-regulating cable.<br />
Floor Tiles<br />
Tile Adhesive<br />
ECOFLOOR Mat<br />
F-BOARD<br />
Tile Adhesive<br />
1 package 2350007<br />
Downpipe clip, 1 package = 25 pcs. Material: frost-resistant plastic. 1 package 2350003<br />
Chain, 1 package = 10 m. Material: frost-resistant plastic. 1 package 2350004<br />
GRUFAST fastening strip, 1 unit =10 m.<br />
Material: zinc-coated steel. Not suitable for outdoor environments.<br />
1 unit 4200013<br />
Plastic cable clip, 1 package = 50 pcs 1 package 1200000<br />
Flex strip, 0.5 m length 1 2350002<br />
T strip, 0.5 length 1 2350008<br />
REPAIR KIT<br />
Kit no. 1 for P1P cable repair 1 5030121<br />
Kit no. 2 for ADSV, ASL1P Mat LD and LDTS cable repair 1 5030122<br />
Kit no. 3 for PSV, MADPSP and ADPSV cable and mat repair 1 5030123<br />
Kit no. 4 for connection and termination of self-limiting cables 1 5030124<br />
Kit no. 5 for MADPSP installed under asphalt 1 5030125<br />
OTHER ACCESSORIES<br />
Aluminium self-adhesive tape, 50 mm width, 50 m length 1 2832515<br />
SYFOK-B – fi xation cables for nonstandard eaves and valleys. Material: frost-resistant plastic.<br />
B/20 (20 m)<br />
B/10 (10 m)<br />
2350010<br />
2350011<br />
SYFOK-P – fi xation cables for nonstandard eaves, gut-<br />
P/20 (20 m) 2350012<br />
ters and valleys. Material: frost-resistant plastic.<br />
P/10 (10 m) 2350013<br />
Cable spacer for 4,5 cm loops, 1 package = 25 pcs. Material: frost-resistant plastic. 1 package 2350014<br />
C-shaped copper roof spacer, 1 package = 25 pcs 1 package 2350005<br />
Sub-Floor – or Existing Floor<br />
(before renovation)
®<br />
ECOFILM<br />
Ecofi lm heating fi lms use state of the art technology and are<br />
primarily used for heating large surfaces. These heating systems<br />
are composed of laminated polyester fi lms with a graphite coating,<br />
supply leads, and accessories. We offer ECOFILM fi lms in<br />
3 versions: underfl oor heating fi lms (“F”), ceiling fi lms (“C”) and<br />
mirror heating fi lms.<br />
ECOFILM set<br />
The do-it-yourself kit for underfl oor heating may be installed easily,<br />
quickly by following the relevant instructions. No professional<br />
installation company required. The fi nal electrical connection<br />
must be carried out by a qualifi ed electrician. As the Ecofi lm set<br />
comes complete for installation, no accessories are needed. We<br />
recommend 60 W/m 2 for a fl oating wooden fl oor and 80 W/m 2<br />
for a fl oating laminated fl oor.<br />
The Ecofi lm set includes:<br />
Ecofi lm F608/55 (F606/55, 1008) electrical heating fi lm<br />
delivered in rolls of various lengths according to the customer’s<br />
requirements and layout plan. The heating fi lm is supplied with<br />
insulated cut edges and cold leads.<br />
An additional pair of insulation discs for insulating the copper<br />
electrodes of the heating fi lm in the event that there is a requirement<br />
to shorten the length of the heating fi lm.<br />
Installation manual.<br />
The fi lm is fi tted with two SK AV1.5 cold leads 3 mm in diameter<br />
and 5 m long.<br />
TYPE<br />
WIDTH [mm] Output<br />
(W/m2 TOTAL ACTIVE )<br />
LENGTH<br />
[m]<br />
Total<br />
Output<br />
[W]<br />
Cat. No.<br />
Eset 60-1,5/50<br />
600 550<br />
60 W/m2 1,5 50 6652495<br />
Eset 60-2/66 2 66 6652500<br />
Eset 60-2,5/83 2,5 83 6652503<br />
Eset 60-3/99<br />
Eset 60-4/132<br />
Eset 60-5/165<br />
(230 V)<br />
3<br />
4<br />
5<br />
99<br />
132<br />
165<br />
6652505<br />
6652510<br />
6652515<br />
Eset 60-6/198 6 198 6652520<br />
Eset 60-8/264 8 264 6652525<br />
Eset 60-10/330 10 330 6652530<br />
Eset 80-1,5/66<br />
600 550<br />
80 W/m2 1,5 66 6652538<br />
Eset 80-2/88 2 88 6652540<br />
Eset 80-2,5/110 2,5 110 6652543<br />
Eset 80-3/132<br />
Eset 80-4/176<br />
Eset 80-5/220<br />
(230 V)<br />
3<br />
4<br />
5<br />
132<br />
176<br />
220<br />
6652545<br />
6652550<br />
6652555<br />
Eset 80-6/264 6 264 6652560<br />
Eset 80-8/352 8 352 6652565<br />
Eset 80-10/440 10 440 6652570<br />
Eset 80-1,5/117<br />
1000 970<br />
80 W/m2 1,5 117 6652708<br />
Eset 80-2/156 2 156 6652710<br />
Eset 80-2,5/195 2,5 195 6652713<br />
Eset 80-3/234<br />
Eset 80-4/312<br />
Eset 80-5/390<br />
(230 V)<br />
3<br />
4<br />
5<br />
234<br />
312<br />
390<br />
6652715<br />
6652720<br />
6652725<br />
Eset 80-6/468 6 468 6652730<br />
Eset 80-8/624 8 624 6652735<br />
Eset 80-10/780 10 780 6652740<br />
26<br />
heating fi lm<br />
The F fi lm is installed directly beneath a fl oating fl oor. Due to its<br />
ultra thin profi le (max 0,4 mm thick) the original construction height<br />
of the fl oating fl oor is hardly affected. This silent, unobtrusive and<br />
dry-laid underfoot heating system is highly reliable and has a long<br />
life span. We provide a 10-year warranty for ECOFILM heating<br />
fi lms, however their operational life can be longer (30–50 years).<br />
The product has been tested according to European standards.<br />
Simplifi ed Example of ECOFILM Set<br />
Design Total surface area 4.3×3.1 m. Heating under laminated fl oor.<br />
Recommended application: ECOFILM Set 80 W/m 2 .<br />
Note: Heating Parts of the fi lm must not overlap and their minimal distance<br />
from fi xtures and wall shall be 5 cm.<br />
Owing to the following note, 3 fi lm strips (1000 mm wide) 3 m long and 2 m long and<br />
2 fi lm strips (600 mm wide) 3 m and 2 m long may be used. For the given application it<br />
is recommended 2×Eset 80-3/234, 1×Eset 80-3/132, 1×Eset 80-2/156 and 1×Eset<br />
80-2/88 + temperature control.<br />
WAGO<br />
WAGO
ECOFILM F – underfl oor heating fi lm<br />
Flexible Ecofi lm heating fi lm is the ideal solution for economical<br />
electric underfl oor heating for laminated and wooden fl oating<br />
fl oors. The product is ultrathin, yet robust, and is a dry-laid system<br />
that is easy to install.<br />
Easy, precise and fast installation<br />
The heating fi lm is produced in rolls 600 mm wide (550 mm<br />
heating surface, two 25 mm non-heating edges) and 1 000 mm<br />
wide (970 mm heating surface, two 15 mm non-heating edges).<br />
Thanks to its special material composition, the heating fi lm may<br />
be cut every 10 mm to obtain exactly the required length of strips.<br />
The strips are laid side-by-side across the entire heating surface<br />
and are interconnected in parallel using cables with connectors.<br />
ECOFILM F heating components must neither overlap nor cross one<br />
another. This method of laying the fi lm saves time and especially<br />
reduces labor costs. Installers will appreciate that the fl oating or<br />
wooden fl oor may be laid immediately after the heating fi lm is<br />
installed and connected.<br />
Gentle and safe heating for your comfort<br />
Heating fi lm makes an ideal fl oor heating system for laminated or<br />
wooden fl oating fl oors. The technical parameters of the heating<br />
fi lm ensure that the materials’ temperature resistance values are<br />
observed. Health safety standards are also maintained too as<br />
the maximum fl oor surface temperature is thermostatically limited<br />
to 27 °C. Traditional heaters which utilise a liquid to transfer the<br />
heat,operate at for example, signifi cantly higher temperature sand<br />
results in a greater fl uctuation in air humidity and undesirable effects<br />
on wooden and laminated fl oors. It is hardly surprising that<br />
this sophisticated system has been used to safely and comfortably<br />
heat in excess of 2,5 million m 2 of fl oors throughout Europe and<br />
has been warmly endorsed by such leading fl oor manufacturers<br />
as PERGO, SCANDIFLOOR, ALLOC, KÄHRS and JUNCKERS.<br />
ECOFILM F<br />
with accessories<br />
Illustration photo—installation of ECOFILM F608 under fl oating fl oor<br />
ECOFILM F connection in<br />
parallel with Mastic<br />
27<br />
TYPE *<br />
WIDTH [mm]<br />
Output [W/m2 TOTAL ACTIVE<br />
] Output [W/m] Cat. No.<br />
Laminate, wood or real timber fl oor<br />
ECOFILM F 608/55 600 550 80 44 6652302<br />
ECOFILM F 606/55 600 550 60 33 6652301<br />
ECOFILM F 604/55 600 550 40 22 6652300<br />
ECOFILM F 1008 1000 970 80 78 6652310<br />
ECOFILM F 1004 1000 970 40 22 6652308<br />
*) delivered in roll, order accessories required for installation<br />
Sectional view of<br />
laminated (wooden) fl oor<br />
(reconstruction)<br />
1 three-layer wooden or<br />
laminate fl oating fl oor<br />
2 fl oor (limitation)<br />
probe in a groove<br />
3 PE foil covering,<br />
0.25 mm thick<br />
4 ECoFILM ® fl oor heating foil<br />
5 insulation underlay from<br />
extruded polystyrene<br />
6 base – concrete, anhydrite,<br />
original fl oor etc.<br />
ideal temperature characteristic<br />
under-fl oor heating<br />
temperature characteristic
ECOFILM C – ceiling heating fi lm<br />
ECOFILM C heating fi lms provide an ideal ceiling heating system<br />
with balanced heat distribution throughout the room (without<br />
temperature gradients). Control of the ECOFILM C’S temperature<br />
I achieved by the use of an electronic thermostat which controls the<br />
room temperature. As it is a radiant heating system, the same comfort<br />
level as achieved by convection heating may be obtained at lower<br />
temperatures. Generally, reducing the temperature by 1 °C lowers<br />
total heating costs by 6 %.<br />
ECOFILM C<br />
with connected cold lead<br />
Installation of connector cover<br />
Illustrative photos of ECOFILM C installation on metal joists<br />
ideal temperature characteristic<br />
ceiling radiant heating<br />
temperature characteristic<br />
Installation: Crimp connector and cold lead<br />
28<br />
TYPE *<br />
WIDTH [mm]<br />
Output [W/m2 TOTAL ACTIVE<br />
] Output [W/m] Cat. No.<br />
ECOFILM C 420 400 300 200 60 6652102<br />
ECOFILM C 414 400 300 140 42 6652202<br />
ECOFILM C 520 500 400 200 80 6652210<br />
ECOFILM C 514 500 400 140 56 6652220<br />
ECOFILM C 510 500 400 100 40 6652225<br />
*) delivered in roll, order accessories required for installation<br />
Sectional view of ceiling structure<br />
1 load-bearing ceiling structure; 2 thermal insulation; 3 CD load-bearing<br />
sections of the plasterboard structure; 4 ECoFILM ® ceiling heating foil<br />
5 PE foil covering, 0.25 mm thick; 6 plasterboard ceiling (fl oating)
ECOFILM MHF – mirror fogging prevention<br />
MIRROR HEATING FILM – perfectly prevents mirror fogging<br />
Safety operation. The Ecofi lm MHF fi lm operates at low temperatures and prevents overheating or damage<br />
to the mirror. Installation is simple and fast. The MHF fi lm has an adhesive layer (with release backing) that<br />
easily sticks to the rear of a mirror. The mirror heater can be wired into the electric circuit of a lighting fi xture<br />
so that it is activated whenever the light is switched on. Considering its low input, the heating fi lms operating<br />
costs are negligible. The ECOFILM MHF heating fi lm requires no maintenance.<br />
ECOFILM ACCESSORIES<br />
black<br />
blue<br />
<strong>Product</strong> Description Amount supplied Cat. No.<br />
Crimp connector for Ecofi lm C and F 1 unit 6651001<br />
Crimp cover for Ecofi lm C 1 unit 6651002<br />
Cold lead 1,5 for Ecofi lm C 1 m 665100x<br />
Cold lead AV 1,5 for Ecofi lm F 1 m 66510x0<br />
Cold lead AV 2,5 for Ecofi lm F 1 m 66510x0<br />
Crimp tool 1 unit 6651003<br />
Insulating tape for sealing<br />
cut edges of heating fi lm<br />
28 mm width/33 m length<br />
38 mm width/33 m length<br />
29<br />
WITH MHF WITHOUT MHF<br />
TYPE Output [W] Dimension [mm] Cat. No.<br />
MHF 12 12,5 274×252 6651850<br />
MHF 25 25 274×574 6651860<br />
MHF 50 50 524×519 6651870<br />
MHF 100 100 524×1004 6651880<br />
1 m cold lead, IP 44, class II<br />
1 roll<br />
6651026<br />
6651028<br />
MASTIC VM connector insulation for Ecofi lm F 38 mm width (1 connector requires 0.1 m) 1m 6651012<br />
WAGO connector (terminal strip) for Ecofi lm set 1 unit 6651007<br />
HEAT-PAK for the placement of ECOFILM F, ECOFILM SET heating foil under a carpet or PVC<br />
This underlay with good thermal conductivity enables the installation of fl oor heating directly under a carpet or PVC when it<br />
isn’t possible to place the heating cable into a screed (for example in the case of additional installation or reconstruction work).<br />
Completely dry installation; raises the fl oor by only 10 mm. The packaging contains 8 boards (4×3 mm thick base boards and<br />
4×4 mm thick covering boards); each of them is coated in a thin layer of adhesive. Laid in two layers, the boards are glued to<br />
each other (staggering of joints is necessary – in this way, the joints don’t show through on the fl oor covering). A rigid, 7 mm thick<br />
compact construction is created onto which PVC or carpet can be laid (freely or glued). Sold only as whole packages.<br />
1 wear layer (PVC, carpet); 2 HEAT-PAK 7 mm two-layer glued underlay; 3 fl oor (limitation) probe in<br />
the groove (embedded); 4 PE foil covering, 0.25 mm thick; 5 ECoFILM ® fl oor heating foil; 6 insulation<br />
underlay from extruded polystyrene; 7 base – original fl oor, concrete anhydrite, etc.<br />
Type<br />
Thickness<br />
[mm]<br />
Capacity<br />
[kg/m 3 ]<br />
Conductivity<br />
[W/mK]<br />
Strength in fl exure<br />
Dimensions of the boards<br />
[m]<br />
Package<br />
[m 2 ]<br />
Cat. No.<br />
HEAT-PAK 7 3 and 4 770 0,07 > 40 kg / cm 2 boards 0,6×1,2 2,88 m 2 5442024<br />
FLOOR INSULATION under wood/laminate fl oor with ECOFILM F, ECOFILM SET heating foil<br />
1 three-layer wooden or laminate fl oating fl oor; 2 fl oor (limitation) probe in a groove;<br />
3 PE foil covering, 0.25 mm thick; 4 ECoFILM ® fl oor heating foil; 5 insulation underlay<br />
from extruded polystyrene; 6 base – concrete, anhydrite, original fl oor etc.<br />
Type<br />
Thickness<br />
[mm]<br />
Bulk density<br />
[kg/m 2 ]<br />
Thermal conductivity<br />
coeffi cient [W/mK]<br />
Load resistance<br />
[t/m 2 ]<br />
Dimensions of insulation<br />
[m]<br />
Package<br />
[m 2 ]<br />
Cat. No.<br />
STARLON 3 3 40 0,0315 5,2 0,5×1,0 boards 5,0 5442003<br />
STARLON 6 6 33 0,0298 6,7 0,5x1,0 boards 5,0 5442006
ULTRATHERM heating for vivariums and terrariums<br />
In 2008 Aztec Europe Ltd. joined FENIX holding. Aztec Europe Ltd.<br />
has its seat in Great Britain and focuses on the production of special<br />
purpose heating elements using mainly ECOFILM foil. These products<br />
include heating systems for vivariums and terrariums.<br />
ULTRATHERM HEATING FILMS AND STRIPS<br />
Viv Strip – heating strips – due to their size, Viv Strip heating strips are suitable mainly for the warming of selected areas within a vivarium<br />
or terrarium housing specifi c types of reptile. Cold lead 2 m. IPX4, class II.<br />
TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.<br />
Ultratherm Viv Strip 11 11<br />
30<br />
230 V / 50 Hz<br />
150×410 8510051<br />
Ultratherm Viv Strip 15 15 150×572 8510053<br />
Ultratherm Viv Strip 23 23 150×868 8510055<br />
Ultratherm Viv Strip 32 32 150×1188 8510057<br />
Viv Mat – heating foils – Viv Mat heating foils are larger than Viv Strip strips and so are used when it is necessary to heat the majority<br />
of the area of a vivarium or terrarium. Cold lead 2 m. IPX4, class II.<br />
TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.<br />
Ultratherm Viv Mat 7 7<br />
274×142 8510001<br />
Ultratherm Viv Mat 15 15 274×276 8510003<br />
Ultratherm Viv Mat 22 22 274×410 8510005<br />
Ultratherm Viv Mat 30 30 230 V / 50 Hz<br />
274×572 8510007<br />
Ultratherm Viv Mat 39 39 274×732 8510009<br />
Ultratherm Viv Mat 46 46 274×868 8510011<br />
Ultratherm Viv Mat 64 64 274×1188 8510013<br />
Happy Hamster – heating foil – due to its dimensions this heating foil is suitable for breeders of various types of rodent. Although rodents<br />
are not primarily heat-loving animals, in the winter season they enter a certain form of winter hibernation and Happy Hamster heating foil is<br />
ideal to help them get through this period in comfort. Cold lead 2 m. IPX4, class II.<br />
TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.<br />
Ultratherm Happy Hamster 8 230 V / 50 Hz 178×280 8510071
ULTRATHERM RADIANT PANELS<br />
ULTRATHERM – radiant heating panels – these panels utilise the principle of infrared radiation and are primarily intended for the<br />
localised heating and warming of breeding places, large terrariums or dog kennels. They are equipped with a thermal fuse which protects the<br />
panel from overheating. It is possible to install them in a vertical position; for horizontal installation it is necessary to order mounting frames.<br />
The standard colour is brown; white versions can be ordered and other colours are possible for an additional fee.<br />
TYPE [W] [V] Coverage Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.<br />
Panel ULTRATHERM 100 h 100<br />
500×320×30 2,5<br />
Recommended height of<br />
60 8515010<br />
installation<br />
Panel ULTRATHERM 200 h 200 750×320×30 3,7 The apertures used for<br />
hanging the ULTRATHERM<br />
45 8515015<br />
Panel ULTRATHERM 270 h 270 230 IP 44 1000×320×30 5,2 panel are on the rear side of<br />
the panel. For the installation<br />
30 8515020<br />
Panel ULTRATHERM 330 h 330 1250×320×30 6,6 of a panel in a horizontal<br />
position it is necessary to<br />
30 8515025<br />
Panel ULTRATHERM 400 h 400 1500×320×30 7,9<br />
order a ceiling frame.<br />
30 8515030<br />
Ceiling fi xing frame for the horizontal installation of ULTRATHERM 100 panels 5401230<br />
Ceiling fi xing frame for the horizontal installation of ULTRATHERM 200–270 panels 5401231<br />
Ceiling fi xing frame for the horizontal installation of ULTRATHERM 330–400 panels 5401232<br />
CERAMIC HEATING BULBS<br />
ULTRATHERM REGULATION<br />
31<br />
Ceramic heating bulbs – heating bulbs (lamps) function on the<br />
principle of infra-red radiation – they imitate the sun’s heat radiation<br />
and thus create conditions close to those in the natural environment.<br />
Heating lamps have a standard screw base which fi ts normal plastic<br />
bulb holders; however, due to the higher operating temperatures<br />
involved, we defi nitely recommend using ceramic bulb holders. The<br />
range, intensity and direction of the heat current can be increased using<br />
an aluminium refl ector. Heating bulbs can be used to create different<br />
temperature zones within a terrarium.<br />
TYPE Output [W] Voltage [V] Cat. No.<br />
100 W ceramic heating bulb 100<br />
8530001<br />
150 W ceramic heating bulb 150 230 V / 50 Hz 8530002<br />
250 W ceramic heating bulb<br />
250 8530003<br />
Ceramic bulb holder for the heating bulb 8530010<br />
AL refl ector for the heating bulb 8530015<br />
Ultratherm Terra-Heat – this thermostat is designed for the checking<br />
of air or soil temperature in a terrarium or vivarium. It is very simple<br />
to use and can be connected to any Ultratherm heating foil or heat<br />
strip, heating cable or mat, and also to other heaters available on the<br />
market with a maximum output of up to 3 600 W.<br />
Description Cat. No.<br />
Settable temperature range 5–49 °C; measured temperature range<br />
5–49 °C; accuracy: ±1 °C; input wattage 230 V, 50 Hz.<br />
8520003
®<br />
ECOFLEX<br />
In convection heating, a heating body is used to warm the air which<br />
then distributes – transfers - heat as it fl ows over the surfaces of<br />
the objects to be heated. Most electrical convector heaters that<br />
our fi rm distributes comes with a precise electronic thermostat, as<br />
standard, with a contact variation of +0.5 °C.<br />
32<br />
convectors<br />
ECOFLEX ET – electric convector with electronic thermostat and pilot wire, 4–5 °C setback control, 230 V/50 Hz. Colour: white.<br />
IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 10<br />
IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.<br />
ECOFLEX ET 500 500 360×400×80 3,3 28 5415305<br />
ECOFLEX ET 750 750 360×400×80 3,3 28 5415307<br />
ECOFLEX ET 1000 1000 440×400×80 3,8 26 5415310<br />
ECOFLEX ET 1250 1250 520×400×80 4,4 20 5415312<br />
ECOFLEX ET 1500 1500 600×400×80 4,9 20 5415315<br />
ECOFLEX ET 1750 1750 760×400×80 5,8 12 5415317<br />
ECOFLEX ET 2000 2000 840×400×80 6,6 12 5415320<br />
ECOFLEX ET 2500 2500 1000×400×80 7,6 12 5415325<br />
ECOFLEX G – glass convector with electronic thermostat and pilot wire, 4–5 °C setback<br />
control, 230 V/50 Hz. Available in black, red, or yellow-green.<br />
IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15. While stocks last.<br />
IP 24 Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.<br />
ECOFLEX G 10 1 000 500×520×100 14 6 54367X0<br />
ECOFLEX G 15 1 500 660×520×100 18 6 54367X2<br />
ECOFLEX G 20 2 000 820×520×100 27 3 54367X4
ATLANTIC F 117 – electric convector with electronic thermostat without pilot wire, for areas not requiring<br />
precise temperature regulation, such as stores and workshops. Colour: white with white grid.<br />
IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15<br />
IP 24<br />
Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.<br />
ATLANTIC F117-05 500 431×493×121 3,5 40 5412150<br />
ATLANTIC F117-07 750 431×493×121 3,5 40 5412152<br />
ATLANTIC F117-10 1000 508×493×121 3,7 34 5412154<br />
ATLANTIC F117-12 1250 579×493×121 4,6 32 5412156<br />
ATLANTIC F117-15 1500 654×493×121 5,3 26 5412158<br />
ATLANTIC F117-20 2000 801×493×121 6,2 22 5412162<br />
ATLANTIC F117-25 2500 950×493×121 7,1 18 5412164<br />
ECOFLEX PREMIER – radiant convector with electronic thermostat and pilot wire,<br />
3.5 °C setback control, 230 V/50 Hz. Colour: white with white grid.<br />
IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 10 / front side, 100<br />
IP 24<br />
Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.<br />
ECOFLEX PREMIER 1000 600×450×115 4,9 20 5435130<br />
ECOFLEX PREMIER 1500 800×450×115 5,8 12 5435132<br />
ECOFLEX PREMIER 2000 1000×450×115 7,7 12 5435134<br />
SOLIUS – radiant convection heater with electronic thermostat, without a pilot wire, Usage: the convection heater<br />
combines the advantages of infrared radiant heating (more economic operation, uniform temperature distribution) and<br />
of convection heating (good dynamics, advantageous price/performance ratio). Also, the so-called “cold fl oor effect” is<br />
partially eliminated in the direction in which the convection heater is emitting radiation. Colour: white casing, white grille IP<br />
rating 24; protection class II.; 1electronic thermostat with a pilot wire; option of installation on a type C or D combustible<br />
base; clearance distances: bottom edge 15cm / side and top edge 10 cm / front wall of the device 100 cm<br />
IP 24<br />
Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.<br />
SOLIUS 750 520×450×98 5,3 20 5435140<br />
SOLIUS 1000 595×450×98 6,0 20 5435142<br />
SOLIUS 1500 815×450×98 8,1 13 5435144<br />
SOLIUS 2000 1035×450×98 10,2 11 5435146<br />
CH 2000 B TURBO – portable convector with electromechanical thermostat<br />
IP 20, class I; needed clearance (cm): bottom edge, 5 / top edge, 10 / front side, 5<br />
IP 20<br />
Type [W] Dimmensions [mm] Weight [kg] Quantity on pallet Cat. No.<br />
CH 2000B - TURBO 750/1250/2000 580×375×110 5,0 20 5410010<br />
33
THERMOSTATS AND CONTROLS<br />
DIGITAL PROGRAMMING THERMOSTATS<br />
<strong>Product</strong> Description Cat. No.<br />
FENIX TFT<br />
WATTS 760<br />
Aube TH 232<br />
FENIX Therm 350<br />
EBERLE FIT 3U<br />
VTM 3000<br />
Digital touch screen thermostat; option of selecting the background colour. Operating<br />
modes ‘fl oor only’, ‘room only’, ‘fl oor+room’; option of measurement with the help of two<br />
external (fl oor) probes, PWM regulation or fi xed temperature difference. 4 preset and<br />
3 user programmes (10 temperature changes in 15 minute steps, with the shortest time<br />
period being 1 hour). Modes: according to the programme, manual mode, holiday, party,<br />
non-freezing temperature, switched off. 16 A switching contact; range of temperature settings<br />
5–35 °C in 0.5 °C steps; option of setting the min. and max. fl oor temperature;<br />
calibration of sensors. A fl oor probe is included with the thermostat.<br />
Programmable thermostat with Fuzzy-Logic option (so-called Intelligent Thermostat) or<br />
fi xed temperature difference (settable at 0.5–7 °C). Operation modes “fl oor only”, “room<br />
only”, “fl oor + room”. 5 preset + 2 user programmes - up to 12 temperature changes/day<br />
with the user programmes. Room temperature setting 5–37 °C in 0.5 °C steps. Option to<br />
set a max. and min. fl oor temperature. Setting of switched wattage for the exact correction<br />
of the room temperature, 16 A switching contact, holiday operation, permanent temperature<br />
mode, switch, key lock, display backlight, choice of two frames – square, round. IP 21<br />
coverage. The back-up of data is provided by a lithium battery – the fi rst charging session<br />
must last at least 24 hours (it is for formatting the capacity of the battery).<br />
This digital thermostat with settable temperature readings (room only / fl oor + room /<br />
fl oor only) is suitable for radiant panels, convection heaters and also fl oor heating. The<br />
thermostat has a 1-week program – it is possible to switch between the comfort (‘day’) and<br />
attenuation (‘night’) temperature up to 4 times per day. Other functions: holiday mode,<br />
non-freezing temperature mode, option of temporary temperature adjustment, display of<br />
current temperature, self-learning mode option (‘fuzzy logic’). IP 21 rating, 16 A switching<br />
contact. A 3 m fl oor probe is part of the thermostat. 230 V power supply. An AC 130-03<br />
snubber must be connected to the thermostat circuit during the switching of induction load<br />
(e.g. when the heating is connected via a contactor) – it should be as close to the contactor<br />
as possible, ideally directly at its contacts. Without the snubber, spontaneous resetting<br />
of the thermostat will take place. This snubber is included with the purchased thermostat.<br />
Programmable digital thermostat with Fuzzy-Logic (so-called Intelligent Thermostat) and<br />
three separate functions: room and fl oor thermostat, fl oor thermostat (factory set) or room<br />
thermostat; two preset programs, possible to use own settings. Each day can be set separately,<br />
four events per day. Air temp. range/fl oor range 5–37 °C, 16 A, frost protection<br />
program, IP 21, power reserve 36 hours, 230 V; equipped with a LED dual function, switch<br />
on/off, lock, adaptive function and switch-on time (as a percentage for the last 24 hours,<br />
7 days, 30 days or 365 days). Floor probe is part of the package.<br />
Programmable thermostat with PWM regulation or fi xed temperature difference. Operating<br />
modes “fl oor only”, “room only”, “fl oor + room”. 13 programmes – 9 pre-set, 4 for users (4<br />
temperature changes per day in 30 minute steps), holiday operation, permanent temperature<br />
or permanent attenuation modes, maintenance of a selected temperature for a set period.<br />
Temperature settable from 5–37°C in 0.5 °C steps (fl oor and room). Option to set the max.<br />
and min. fl oor temperature, option of probe calibration. Technical parameters: 16 A switching<br />
contact, switch, key lock, back-lit display, automatic change to summer time. Floor probe<br />
is part of the package. Lithium battery used for data back-up – the fi rst charging must last at<br />
least 24 hours (formatting of the capacity of the battery), IP 30.<br />
Selection of weekly or daily programme, selection of the modes “fl oor only”, “room only”,<br />
“fl oor + room”. 6× daily switching between the pre-set comfort and attenuation temperatures.<br />
Option to manually change the temperature with an automatic return to the programme.<br />
Other functions: permanent maintenance of comfort or attenuation temperatures,<br />
anti-freeze protection, permanent maintenance of manually set temperature (simulation of<br />
an analogue thermostat), setting of max. and min. fl oor temperature, operating hour counter.<br />
Data and programme back-up in the EEPROM memory (up to 10 years), time and date<br />
back-up with the help of a large-capacity capacitor – period of back-up 6 hours. Technical<br />
parameters: switching contact 16 A / 230 V, max. switched wattage 2 kW, key lock, fl oor<br />
probe part of the package. IP 31.<br />
34<br />
4200152<br />
4200123<br />
4200118<br />
4200128<br />
4065005<br />
4200134
ANALOG ROOM THERMOSTAT<br />
<strong>Product</strong> Description Cat. No.<br />
FLASH 25800 10 A, bimetallic thermostat with signaling, without temperature setback, 5–35 °C, IP 30. 4200110<br />
EBERLE RTR - E 6124 10 A, with temperature setback 5 K, accuracy 0.5 K, 5–30 °C, IP 30. 4066020<br />
FENIX-Therm 100<br />
12 A, IP 21, heat differential of 0.5 °C, switch, 0–45<br />
5–30 °C (ambient air), 5–50 °C (fl oor)<br />
35<br />
4200130<br />
Frame for FENIX-Therm 100 Frame for use in wall mounting. 4200131<br />
TH 810 T<br />
WIRELESS REGULATION SUITABLE FOR ECOSUN, MR AND GR PANELS<br />
BPT-SP<br />
wireless control unit<br />
– transmitter<br />
SP1<br />
wireless receiver<br />
– fl ush-mounted<br />
SP2<br />
wireless receiver<br />
– wall-mounted<br />
SP3<br />
wireless receiver<br />
– socket<br />
PH-TS 20<br />
programmable socket<br />
PH-CJ 37 SW<br />
central control unit<br />
GSM PH-GST 1 module<br />
The outlet thermostat adjusts the outlet according to the set room temperature. Temperature<br />
range is 5–30 °C (±1 °C). Optional mode for cooling/heating.Maximum switched current<br />
is 16 A (3,500 W). Maximum time for backed-up operation is 3 hours. Displays both<br />
set and current temperature in the room. Does not allow time programming. IP 20.<br />
2–39 °C, adjustable difference of switching 0.1–1.5 °C, PI-PWM, fuzzy logic, 9 select<br />
programmes, each programme up to six changes, option of differentiating between an<br />
odd and even week, 255 transmitters can be connected to different addresses, simple<br />
pairing receiver/transmitter, summer regime function, holiday, party, 2×1.5 V AA power<br />
supply, placement on a wall or on a stand, range 35 m in buildings , up to 300 m in open<br />
areas, frequency 433.92 MHz, option of control using a text message with the help of an<br />
additional GSM module, GST 1, (not included in the price). IP 20.<br />
16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms<br />
the change, frequency 433.92 MHz, indication of operational status with LED diodes,<br />
connection in mounting box.<br />
16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms<br />
the change, frequency 433.92 MHz, indication of operational status with LED diodes, to<br />
be mounted on a wall or in mounting box.<br />
16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms<br />
the change, frequency 433.92 MHz, indication of operational status with LED diodes,<br />
insertion into a 230 V / 16 A socket.<br />
The PH-TS 20 socket is basically an SP3 receiver to which buttons, a display and a temperature<br />
sensor were added so that the socket can be programmed directly and the BPT-SP<br />
control unit is no longer needed for its operation. The PH-TS 20 programmable socket can<br />
also communicate wirelessly with the PH-CJ 37 SW central unit, and therefore it can also<br />
be included in the PocketHome central regulation system. IP 20.<br />
The PH-CJ 37 SW central regulation unit is intended for the control of all BPT-SP units<br />
in the building. Using it creates a central regulation system for the whole building. The<br />
package also includes PocketHome software for the PC, a connecting cable for the PC’s<br />
serial COM port and reduction to USB (RS232/USB convertor). The software enables<br />
the programming and control of the whole regulation system to be managed signifi cantly<br />
better and more clearly than by using the buttons and display of the PH-CJ 37 SW central<br />
control unit. IP 20.<br />
The GSM module is used for the remote control of the Fenix BPT-SP control unit. With the<br />
help of text messages from your mobile phone, the temperature in the room can be regulated<br />
or the current state of the control unit can be ascertained. SIM card is not included<br />
in the price.<br />
4065110<br />
4500330<br />
4500332<br />
4500334<br />
4500336<br />
4500342<br />
4500340<br />
4500338
<strong>Product</strong> Description Cat. No.<br />
INDUSTRIAL ROOM THERMOSTAT<br />
ANALOG WALL-MOUNTED THERMOSTATS WITH INCREASED PROTECTION (IP 54)<br />
EBERLE AZT - A 524510<br />
EBERLE AZT - A 524410<br />
EBERLE AZT - I - 524510<br />
EBERLE AZT - I - 524410<br />
CONTROLLERS FOR GUTTERING AND OUTSIDE SURFACE HEATING<br />
Eberle EM 524 89<br />
(one-zone)<br />
Eberle EM 524 90<br />
(two-zone)<br />
Set of EBERLE sensors<br />
for eaves troughs<br />
Set of EBERLE<br />
ground sensors<br />
EBERLE DTR-E 3102<br />
OJ Electronik<br />
ETR/F-1447A<br />
REGULATORS TO CONTROL ATTENUATION AND TIME PROGRAMMABLE SWITCHES<br />
FLASH Programmer 2 SED<br />
REGULATORS FOR REDUCTION OF MAIN CIRCUIT BREAKER VALUE<br />
Three-phase current-load reliever – 6 modules.<br />
BMR HJ 103<br />
BMR HJ 306<br />
Built-in space sensor and exterior scale. Ambient air sensor 5–35 °C, 10 A,<br />
accuracy 1–5 K.<br />
Built-in space sensor and exterior scale. Ambient air sensor -15–15 °C, 10 A,<br />
accuracy 1–5 K.<br />
Built-in space sensor and interior scale. Ambient air sensor 5–35 °C, 10 A,<br />
accuracy 1–5 K.<br />
Built-in space sensor and interior scale. Ambient air sensor -15–15 °C, 10 A,<br />
accuracy 1–5 K.<br />
Regulator for the heating of eaves troughs, downpipes and outdoor surfaces – pavements<br />
and drives. In contrast with a manual or thermostatic controller it enables the achievement<br />
of operational cost savings of up to 80 %. Functions: setting of temperature and humidity,<br />
operating hours counter, alarm output, delayed switching off, current temperature indicator.<br />
Placement on a DIN strip (8 modules), CZ menu. The presence of humidity (water,<br />
snow or ice) and the outdoor temperature are monitored with the help of external sensors<br />
which need to be ordered separately – for eaves troughs or free areas, depending on the<br />
application. IP 20.<br />
A two-zone regulator for the heating of eaves troughs, downpipes and outdoor surfaces.<br />
The parameters and functions are the same as for the EM 524 89. However, the regulator<br />
enables independent monitoring and control of two applications simultaneously. Basically,<br />
these are two EM 524 89 regulators in one. Both zones require the connection of their own<br />
set of sensors – for eaves troughs or free areas, depending on the application – and these<br />
need to be ordered separately. IP 20.<br />
36<br />
4066010<br />
4066005<br />
4066012<br />
4066007<br />
4600015<br />
4600016<br />
Humidity (ESD 524 003) and temperature (TFD 524 004) sensor for EM 524 89 and<br />
EM 524 90 regulators for controlling the heating of eaves troughs and downpipes. IP 65. 4600051<br />
Humidity (ESF 524 001) and temperature (TFF 524 002) sensor for EM 524 89<br />
and EM 524 90 regulators for controlling the heating of outdoor surfaces. IP 65.<br />
Differential thermostat, 230 V, 1 × switching off / 1 × switching contact 16 A, 20–35 °C,<br />
IP 65 (can be placed e.g. on the facade). While being operated it requires careful monitoring<br />
to attain economical operation.<br />
Differential thermostat; 230 V, 1 × switching contact 16 A, -15–10 °C, IP 20, on DIN rail<br />
(3 modules), room sensor (IP 44) included in the price. While being operated it requires<br />
careful monitoring to attain economical operation.<br />
The regulator uses a pilot wire for switching between comfort and attenuation temperatures.<br />
There is the option to divide a building into two zones and set individual weekly<br />
programmes for each of them. A week is divided into 7 days; each day can be allocated<br />
one of three pre-set programmes or an individual programme can be created (different for<br />
each day). In the case of individual programming, a day is divided into 30-minute intervals.<br />
There is the option of “holiday” operation – a temperature above freezing point (+7 °C)<br />
is maintained for a period of 1 to 99 days, followed by a return to the programme mode.<br />
Outputs: sinusoid 230 V / 50 Hz, positive and negative half-wave, the potential of a neutral<br />
conductor for all types of convectors and thermostats. Dimensions 83×70×17 mm, programme<br />
back-up 12 hours, IP 30 coverage. Placement on KU 68.<br />
Three-level regulation with breaking for three phases, 3×3 A,<br />
current settings of 1 to 120 A with precision to 1 A. IP 20.<br />
Two-level regulation with separate breaking for individual phases, 6×3 A,<br />
current settings of 1 to 120 A with precision to 1 A, size 6 modules. IP 20.<br />
4600050<br />
4066038<br />
4600010<br />
4100025<br />
4200232<br />
4200032
STORAGE HEATERS<br />
1 2<br />
3<br />
5<br />
1 storage bricks 2 Heating elements<br />
3 Microtherm ® insulation 4 Charge controller<br />
5 Bypass system 6 Wall bracket<br />
7 Charge adjustment 8 Vermiculite insulation<br />
9 Fan 10 Auxiliary heating element (optional)<br />
10<br />
* available on a special order<br />
8<br />
4<br />
6<br />
9<br />
7<br />
ECOSTATIC – Static Storage Heater<br />
Basic Characteristics and Benefi ts<br />
Manually controlled electric storage heater<br />
Input and output adjustment according<br />
to the required comfort<br />
Attractively styled to suit modern home and offi ce decor<br />
Very low lifetime maintenance<br />
Safe, easily controllable and highly reliable<br />
Upgraded and adjusted for use in bathrooms (IP X2)<br />
IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging + electromechanical thermostat<br />
for the control of discharging; * the WMX 706 type is without controlling thermostats; option of installation on a C or<br />
D fl ammable base; Needed clearance: side edges 75 mm, top edge 250 mm, front wall 300 mm<br />
IP X2 Type Input [kW] Max. capacity [kWh] Voltage [V] Dimmensions [mm] Weight [kg] Cat. No.<br />
WMX 706 * 0,85 6<br />
332×700×183 41 5604706<br />
WMX 712<br />
WMX 718<br />
1,70<br />
2,55<br />
12<br />
18<br />
230 ~ 50Hz<br />
560×700×183<br />
788×700×183<br />
77<br />
110<br />
5604712<br />
5604718<br />
WMX 724 3,40 24 1016×700×183 140 5604724<br />
ECODYNAMIC – Dynamic Storage Heater<br />
Basic Characteristics and Benefi ts<br />
Electric fan storage heater with controllable heat output according to the<br />
Standards DIN 44574, IEC 60531 and the Safety Standard VDE 0720<br />
Equipped with a thermomechanical charge controller (liquid fi lled)<br />
and a thermomechanical safety controller (bimetal)<br />
Airfl ow in two channels inside the core<br />
One brick type for all heater models (material: magnesite MgO)<br />
High-quality Vermiculite and Microtherm ® insulation (achieving<br />
lower surface temperatures and better heat accumulation)<br />
Only 25 cm deep<br />
No start-up procedure; may be operated by user immediately after installation<br />
Tube heating elements (special alloy steel)<br />
Radial fl ow fan for quiet and steady heat output<br />
Discharge controlled with an external room thermostat*<br />
Air outlet with bimetal fl ap system for high and constant heat output (automatic)<br />
Auxiliary heating element* installed in the air outlet area<br />
Sheet steel casing, phosphatized and enameled; colour:<br />
creme-white with gray-brown air outlet grill<br />
With a wall spacer and either supporting feet* or a fl oor plate*<br />
Protective cover* for bathrooms<br />
IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging; option of installation on a C or<br />
D fl ammable base; Needed clearance: side and top edge 100 mm, front wall 300 mm<br />
IP X0 Type Input [kW] Max. capacity [kWh] Voltage [V] Dimmensions [mm] Weight [kg] Cat. No.<br />
VFMi 20<br />
VFMi 30<br />
VFMi 40<br />
2,0<br />
3,0<br />
4,0<br />
16<br />
24<br />
32<br />
factory setting<br />
400–3N ~ 50Hz<br />
may be changed<br />
626×672×250<br />
776×672×250<br />
926×672×250<br />
98<br />
137<br />
176<br />
5604020<br />
5604030<br />
5604040<br />
VFMi 50<br />
VFMi 60<br />
VFMi 70<br />
5,0<br />
6,0<br />
7,0<br />
40<br />
48<br />
56<br />
by a qualifi ed<br />
technician to<br />
230 ~ 50Hz<br />
1076×672×250<br />
1226×672×250<br />
1376×672×250<br />
215<br />
254<br />
293<br />
5604050<br />
5604060<br />
5604070<br />
37
ATLANTIC electric water heater<br />
Local heating not only provides you extra comfort, it also conserves<br />
electricity and water. Since these heaters are quite small, you can<br />
easily build one into a kitchen counter or the cabinet under the sink.<br />
Your kitchen’s aesthetics can thereby be preserved.<br />
Principal characteristics and advantages<br />
Low-volume units heat water very close to the place where it is to<br />
be used. This eliminates the large losses typical of central hot water<br />
sources, where pipes leading from the central boiler sap the water’s<br />
heat as they pass through walls.<br />
Type Capacity [l] Voltage [V] Input [W] IP protection Heating time Net weight [kg] Height [mm] Diameter [mm] Cat. No.<br />
ATL 10 L 10<br />
38<br />
thermal insulation from polyurethane foam<br />
hot water outlet pipe<br />
enameled inner pressure tank<br />
exchangeable magnesium anode<br />
thermostat temperature sensor<br />
cold water inlet<br />
electrical heating element<br />
removable access fl ange<br />
thermostat<br />
1600 IP 25 0h 24min 8 456 255 5451001<br />
ATL 10 LU 10 2000 IP 24 0h 19min 8 456 255 5451002<br />
ATL 50 L 50 220–240<br />
1h 30min 16 559 433 5455001<br />
2000<br />
ATL 80 L 80 IP 25 2h 26min 20 791 433 5455010<br />
ATL 150 L 150 2200 4h 36min 40 1241 505 5455030<br />
SUPPLEMENTARY PRODUCTS<br />
HAND DRYERS – electric hot-air units with fans for hands drying. Wall-mountable. Automatic<br />
sensor switch ensures hygienic operation. Type ZY - 202 (metal) – while stocks last.<br />
Type Output Switching<br />
sensor<br />
Air<br />
temperature Tension<br />
Dimension<br />
[mm]<br />
Weight<br />
[kg]<br />
Cat. No.<br />
ZY - 203 A (plastic) 1800 W 14–18 cm 50–70°C<br />
~ 230 V 240×240×240 2,5 5440010<br />
ZY - 202 A (metal) 2700 W 12–18 cm 45–55°C 50 Hz 361×242×156 5,0 5440005<br />
ELECTRIC TOWEL DRYERS are intended mainly for use in<br />
bathrooms, washrooms, showers or kitchens for the drying of damp<br />
towels, bath towels, tea towels etc. The installation is simple – the dryer<br />
is attached to the wall using three plastic grips and the supply lead<br />
is connected to a standard socket. The heating element is protected<br />
from overheating by a thermal fuse;<br />
the element doesn’t contain any<br />
fi lling and therefore there is no<br />
danger of freezing, air intake<br />
or leakage of the liquid.<br />
Type sTR - CR (chrome)<br />
– while stocks last.<br />
Output 100 W, voltage 230 V /<br />
50 Hz, IP 44 coverage, insulation<br />
class I., switch with a light which<br />
signals operation, 1.6 m long straight<br />
supply cable with a plug.<br />
Type Colour<br />
Width<br />
[mm]<br />
Height<br />
[mm]<br />
Depth<br />
[mm]<br />
Weight<br />
[kg]<br />
Cat. No.<br />
STR - W white<br />
5441006<br />
590 662 25 3,9<br />
STR - CR chrome 5441007<br />
ZY - 203 A (plastic)<br />
ZY - 202 A (metal)<br />
TUBULAR HEATING ELEMENTS – with an electric heating insert.<br />
Intended primarily for bathrooms – suitable for drying bath towels,<br />
hand towels etc.<br />
IP 65 coverage. Voltage 230 V / 50 Hz. White RAL 9016;<br />
fi lled with non-freezing mixture, 1 m coiled connection<br />
cable (extends to 3,5 m) with plug. Mounting brackets<br />
are included with the product. The heating element is<br />
without a thermostat. It can be combined with a TH 810 T<br />
plug in thermostat.<br />
Type Wattage Width<br />
KD-E – fl at<br />
[mm]<br />
Height<br />
[mm]<br />
Depth<br />
[mm] Weight<br />
[kg]<br />
Cat. No.<br />
KD-E 450×960 300 450 960 90 11,5 5441402<br />
KD-E-600×960 400 600 960 90 13,0 5441404<br />
KD-E-450×1320 400 450 1320 90 15,8 5441406<br />
KD-E-600×1320 600 600 1320 90 18,0 5441408<br />
KD-E-750×1680 900 750 1680 90 27,0 5441410<br />
KDO-E – rounded<br />
KDO-E 450×960 300 450 960 120 11,5 5441412<br />
KDO-E 600×960 400 600 960 120 13,0 5441414<br />
KDO-E 450×1320 400 450 1320 120 15,8 5441416<br />
KDO-E 600×1320 600 600 1320 120 19,0 5441418<br />
KDO-E 750×1680 900 750 1680 120 27,0 5441420
Argentina<br />
Armenia<br />
Australia<br />
Austria<br />
Belorussia<br />
Benelux<br />
Bosnia and<br />
Herzegovina<br />
Brazil<br />
Bulgaria<br />
EXPORT MARKETS<br />
Canada<br />
Columbia<br />
Croatia<br />
Cyprus<br />
Czech Republic<br />
Denmark<br />
Estonia<br />
Finland<br />
France<br />
Georgia<br />
Germany<br />
Great Britain<br />
Greece<br />
Hungary<br />
Chile<br />
Iran<br />
Ireland<br />
Israel<br />
Italy<br />
Japan<br />
Korea<br />
Kazakhstan<br />
Kingdom of Jordan<br />
Latvia<br />
Lebanon<br />
Lithuania<br />
Macedonia<br />
Malta<br />
Montenegro<br />
Netherlands<br />
New Zealand<br />
Norway<br />
Poland<br />
Portugal<br />
Romania<br />
Russia<br />
Serbia<br />
Slovakia<br />
Slovenia<br />
Spain<br />
www.fenixgroup.eu<br />
Sweden<br />
Switzerland<br />
Tajikistan<br />
Turkey<br />
Ukraine<br />
Uruguay<br />
USA
HEADQUARTER<br />
FENIX GROUP a.s.<br />
Šárecka 37, 160 00 Praha 6, Czech Republic<br />
E-mail: fenix@fenixgroup.cz<br />
FENIX TRADING s.r.o.<br />
Slezská 2, 790 01 Jeseník, Czech Republic<br />
Tel.: +420 584 495 111, 584 495 302<br />
Fax: +420 584 495 303<br />
E-mail: fenix@fenixgroup.cz<br />
PRODUCTION PLANT<br />
FENIX s.r.o.,<br />
Jaroslava Ježka 1338/18a<br />
790 01 Jeseník, Czech Republic<br />
E-mail: obchod@fenixgroup.cz<br />
FLEXEL INTERNATIONAL LTD.<br />
Glenrothes, Fife, Scotland<br />
www.fl exel.co.uk<br />
E-mail: sales@fl exel.co.uk<br />
CEILHIT, S.L.<br />
Poligono Industrial Cami Ral<br />
C/Galileo 38-40, 08850 Gava, Spain<br />
E-mail: comercial@ceilhit.es<br />
BRANCH STORE<br />
FENIX BOHEMIA<br />
Vejvanov 17, 338 28 Radnice<br />
Czech Republic<br />
E-mail: bohemia@fenixgroup.cz<br />
FENIX SLOVENSKO s.r.o.<br />
Iliašská cesta 86<br />
974 01 Bánská Bystrica, Slovakia<br />
E-mail: fenix@fenix.sk<br />
ACSO<br />
11 bis, boulevard carnot – 81270<br />
Labastide-Rouairoux, France<br />
E-mail: acso@acso.fr<br />
FENIX TRADING s.r.o. Slezská 2, 790 01 Jeseník, Czech Republic;<br />
Tel.: +420 584 495 111, 584 495 302; Fax: +420 584 495 303; E-mail: fenix@fenixgroup.cz<br />
www.fenixgroup.eu