Method 5769<br />

<strong>ASTM</strong><br />

Member<br />

<strong>ASTM</strong> Method D-5769-98<br />

Benzene, Toluene, and Total Aromatics in Finished Gasoline by GC/MS<br />

<strong>ASTM</strong> D-5769 Benzene, Toluene & Total Aromatics in Finished Gasoline by GC/MS<br />

42<br />

<strong>ASTM</strong> <strong>Standards</strong><br />

All of your standards requirements for <strong>ASTM</strong> Method D-5769 have been put together in the<br />

following 10 pages. These standards and methods are used in the monitoring of Total<br />

Aromatics according to the latest methods and amendments to the US Clean Air Act.<br />

A set of Amendments, containing more stringent specifications became effective January 1,<br />

1995 limiting the volatility and composition of reformulated gasoline.<br />

The D-02 Committee of the American Society of Testing Materials, developed a standard test<br />

method D-5769 for the determination of the analyte composition by GC/MS of reformulated<br />

gasoline.<br />

Aromatic Product Line yields the following important benefits<br />

Features: Benefits:<br />

Purity and Identity of all analytes verified .......... Impurity interferences in analyte retention time<br />

under identical operating conditions window are compensated.<br />

Certified method specific calibration standards . Increased confidence in analytical results.<br />

Eliminates preparation of calibration standards ..Time is utilized quantifying actual samples.<br />

Internal <strong>Standards</strong> Incorporated .........................Saves time.<br />

Weights and weight percents provided .............. Ease of use in performing back calculations.<br />

Includes all necessary solutions .........................Complete single source for reference materials.<br />

Variations in packaging size .............................. Meet laboratory sample volumes and demands.<br />

Low Cost ............................................................ More economical to purchase than to prepare standards.<br />

Flexibility ............................................................ Meet your lab requirements/method changes.<br />

Only 5 standards needed for a 5 Point Curve ... Generate a full calibration curve in 1/2 the time of the<br />

two set version composed of 10 standards.<br />

No charge disk deliverable calibration curve .... Direct computer uploading eliminates the input of 135<br />

weights (CALAMTS) separate data points.<br />

Originally designed for<br />

D-5769-98<br />

Quality System is Certified to comply with the International ISO 9001 Quality Standard