COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM<br />

81<br />

Master / Sub Intercom<br />

MASTER<br />

1<br />

SUB<br />

120<br />

NEM<br />

Features<br />

l Lamp memory intercom: Sub’s call-in with tone & light<br />

l Press-to-talk or handset with voice actuation<br />

l Selective or group call of 10 subs<br />

l All Call<br />

l Pre-tone sounding at sub, when selected<br />

l Optional accessories for health care applications<br />

l Expand beyond 40 stations with add-on selectors<br />

Communication network<br />

NEM-40A/C<br />

1.<br />

2.<br />

3.<br />

NA-A<br />

NA-A<br />

NA-NE NA-A NA-A NA-NE<br />

1. Selective individual call 2. Selective group call (max. 10) 3. All call<br />

Wiring<br />

1.<br />

2.<br />

3.<br />

Master station Sub station<br />

NEM-10/C<br />

10-call master<br />

NEM-10A/C<br />

10-call master<br />

Power supply<br />

NEM-40A/C<br />

NEM-40A/C<br />

NEM-60A<br />

NEM-20/C<br />

20-call master<br />

NEM-20A/C<br />

20-call master<br />

2 x n<br />

2 x n<br />

2 x n1<br />

2 x n2<br />

NA-A<br />

2<br />

NEM-30/C<br />

30-call master<br />

NEM-30A/C<br />

30-call master<br />

PS-2420S PS-2420UL PS-2420 m P.104<br />

NA-A<br />

2<br />

NA-A NA-A NA-NE<br />

2 2 2<br />

NA-A NA-A NA-NE<br />

2 2 2<br />

2 2<br />

NA-NE<br />

NA-A NA-A NA-NE<br />

1. Run a parallel cable to each NA sub station (in the same conduit).<br />

2. Run a multi-conductor cable(s) throughout system.<br />

3. Run multi-conductor cables up to junction box, then run a parallel cable to<br />

each NA sub station.<br />

2<br />

2<br />

NEM-40/C<br />

40-call master<br />

NEM-40A/C<br />

40-call master<br />

Wiring<br />

IER-2<br />

1<br />

E<br />

S<br />

S<br />

PS24 - +<br />

NEM-40A/C<br />

1<br />

2<br />

3<br />

4<br />

10<br />

E<br />

31<br />

32<br />

33<br />

34<br />

40<br />

E<br />

NB-L<br />

Ceiling sub station<br />

NA-A<br />

Sub station<br />

Homerun<br />

A<br />

B<br />

C<br />

D<br />

E<br />

A<br />

B<br />

C<br />

D<br />

E<br />

A<br />

B<br />

C<br />

D<br />

E<br />

RD<br />

OG<br />

OG/WH<br />

BL<br />

GR<br />

BK<br />

NA-AN NA-AN NA-AN<br />

A<br />

B<br />

C<br />

D<br />

E<br />

NA-NE<br />

Sub station<br />

NA-AN<br />

Privacy sub station<br />

NA-AN NA-AN<br />

NA-NE<br />

A RD<br />

B OG<br />

C OG/WH<br />

D BL<br />

E GR<br />

BK<br />

NA-NE<br />

N : PS-2420S, PS-2420UL, PS-2420<br />

RD: Red OG: Orange OG/WH: Orange/White BL: Blue GR: Green BK: Black<br />

IMPORTANT: For NE-JA sub(‘s), homerun wires to secure stable calling and<br />

distance of 270m w/1.0mma.<br />

1<br />

2<br />

3<br />

4<br />

NE-JA