Expanda Cable power cord located inside ... - Clyde Bergemann, Inc.
Expanda Cable power cord located inside ... - Clyde Bergemann, Inc.
Expanda Cable power cord located inside ... - Clyde Bergemann, Inc.
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Problem: <strong>Expanda</strong> <strong>Cable</strong> <strong>power</strong> <strong>cord</strong> <strong>located</strong> <strong>inside</strong><br />
sootblower housing on IK525/525R/IKSD<br />
Issues: NO Accessibility for maintenance and periodic<br />
Adjustments<br />
Impossible to inspect and PM<br />
Each travel and each hand requires different cables<br />
Improper adjustment causes failure, which can be costly<br />
Solution: <strong>Clyde</strong> <strong>Bergemann</strong>, <strong>Inc</strong>. “E-Chain” conversion kit or<br />
external expanda cable kit<br />
Advantages: Both kits are externally mounted to facilitate inspection and preventive maintenance<br />
Eliminates expensive coiled <strong>cord</strong>s (E-Chain)<br />
Uses standard SO <strong>cord</strong> (E-Chain)<br />
Both kits provide disconnect at motor<br />
Both kits retrofitable in field<br />
The expanda cable <strong>power</strong> <strong>cord</strong> is <strong>located</strong> <strong>inside</strong> the sootblower housing and provides <strong>power</strong> to the motor<br />
over the course of the travel. The cable is mounted on a suspension rod, which covers the entire length of<br />
the blower. An extension cone (later a floating cone) aids the coiling and uncoiling of the expanda cable<br />
during an operation. The cable can get lodged between the cone and rod and short out if not adjusted<br />
properly. The cable loops must be of the proper size to assure clearance in it’s confined space or service<br />
life is sacrificed. The location of the cable in proximity to the feedtube packing has been known to cause<br />
the cable to lose its shape and sag into the gear rack.<br />
The <strong>Clyde</strong> <strong>Bergemann</strong>, <strong>Inc</strong>. “E-Chain” conversion consists of a retractable cable carrier (“E” chain) which<br />
is supported by a simple trey system. The <strong>power</strong> <strong>cord</strong> is <strong>located</strong> <strong>inside</strong> the cable carrier and is standard<br />
“SO” <strong>cord</strong> and a disconnect at the motor is provided. A towbar mounted to the carriage assembly pulls the<br />
cable carrier along and the treys support the cable of the length of travel.<br />
The <strong>Clyde</strong> <strong>Bergemann</strong>, <strong>Inc</strong>. External <strong>Expanda</strong> <strong>Cable</strong> kit moves the expanda cable to the outside of the<br />
blower. The same coiled <strong>cord</strong> is used; however, maintainability and accessibility are greatly improved.<br />
UPGRADE OPTIONS:<br />
Both the “E” chain kit and the External expanda cable kits are available with external limit switches for the<br />
utmost in complete electrical system maintainability. Magnetic proximity switches are provided with<br />
required mounting brackets and hardware for complete installation.