MAINTENANCE - Fig. 38 to 40<br />

English<br />

Fig. 38 – CLEANING OF THE PRIMARY FILTER at the inlet of the HP cleaner<br />

Check on a regular basis the state of the water filter placed in the quick coupling of the<br />

pump inlet: A simple sand grain can result in valve breakdown (symptoms: pressure loss and<br />

vibration in the HP hose) or By-pass breakdown.<br />

Fig. 39 & 40 – Axial Pump<br />

The cleaner-unclogger is equipped with an axial pump whose 3 pistons are activated by an<br />

oblique disk system: A flask contains the oil which enables the lubrication of the moving parts<br />

by splash lubrication (no loss, contrary to an automobile!).<br />

The factory set oil level does not need to be changed often.<br />

The oil, in time, will lose its lubricating power and be saturated with small metal particles<br />

(created by the friction of the parts), and it will be necessary to have it changed after 2 years, or<br />

1 and a half years if you make intensive use of your cleaner (over 100 hrs /year).<br />

CHART OF RECOMMENDED MAINTENANCE<br />

CHECKS TO B CARRIED<br />

OUT<br />

2 YEAR GUARANTEE PERIOD 3rd 4th<br />

NECESSARY OPERATIONS TO BE CARRIED OUT YEAR 1 Or 150 hrs YEAR 2 Or 250 hrs YEAR YEAR<br />

Check of HP Cleaner functions: Pressure / Flow / TOTAL STOP X X X X<br />

Check / Cleaning water inlet FILTER X X X X<br />

Checking of the integrity of the HP HOSE & of the GUN (no leaks) X X X X<br />

Check of the LANCES / Pipe UNCLOGGER X X X X<br />

Check of the integrity of the electric Cable & Plug X X X X<br />

Check of the VENTURI KIT at the By-pass X X<br />

Check of the CONTROLS & DETERGENT HOSES X X<br />

Check of the PISTONS / WATER SEALS / OIL SEALS<br />

X<br />

REPLACEMENTS TO BE<br />

CARRIED OUT<br />

Replacement of the HP Hose & of the Pipe unclogger if necessary<br />

X<br />

Replacement of the O-rings: Hoses & Gun X X<br />

Replacement of HP Gun if necessary<br />

X<br />

Replacement of LANCES (MULTIJET and/or TURBO) if necessary<br />

X<br />

Replacement of WATER INLET FILTER if necessary X X<br />

Replacement of DETERGENT HOSES & STRAINER<br />

X<br />

Replacement of valve kits (HP/LP) + By-pass kit<br />

X<br />

Replacement of PUMP Oil<br />

X<br />

Replacement of WATER SEALS / OIL SEALS<br />

X<br />

Replacement of PISTONS & their return SPRINGS<br />

X<br />

Any MAINTENANCE OPERATION ON INTERNAL PART, carried out by unauthorized<br />

personnel, will void the guarantee.<br />

FAILURE TO CARRY OUT MAINTENANCE can also void the guarantee.<br />