08.07.2015 Views

Gama de productos 2009 - Hauraton.com

Gama de productos 2009 - Hauraton.com

Gama de productos 2009 - Hauraton.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FASERFIX ® Superejemplo <strong>de</strong> instalacion en hormigoncl. A 15 – C 2501234567AInstallation exampleConcrete cl. A 15 - C 2503 - 5 mmA100 up to 150 cmExpansion jointBConcrete wearing layerBhBase courseCbCdFrost resistant sub-baseD* h Channel height - 10 cmDCategory according to EN 1433 / DIN V 19580A 15 B 125 C 250D 400** E 600 F 900Applying to follwing channel systems:Foundation: with b / thickness d / height h (in cm)The named concrete quality is a minimum qualityEN 206-1 / without danger of frost on the lateral supportDIN 1045-2 with danger of frost on the lateral support10 / 10 / * 10 / 10 / * 10 / 15 / *C 20/25 C 20/25 C 20/25C 25/30 XF1 C 25/30 XF1 C 25/30 XF1FASERFIX SUPER KS 100, 150, 200, 300FASERFIX SUPER 150, 200, 300, 400, 500The installation examples / advise constantly are adapted to the technical conditions.With new editions ol<strong>de</strong>r expenditures lose their validity.Before planning or installation please verify the current version at www.hauraton.<strong>com</strong>ECondition: 26.02.2007Our general installationinstructions apply.Surface:ConcreteE** In Class D 400 not for use across the carriagewayof highways or motorways in moving traffic. For this application were<strong>com</strong>mend our channel systems FASERFIX TRAFFIC SUPERBLOCor FASERFIX TRAFFIC GUGIBLOC12Description: FF-S-200 Typ 010_Einbau Klasse C 250 in Beton_GBDrawing-no.: C:\pdmwe\inventor\2007\05\0\0000014804.idw34 5 67ejemplo <strong>de</strong> instalacion en hormigoncl. D 400 – F 9001234567AInstallation exampleConcrete cl. D 400** - F 900bExpansion joint3 - 5 mmAConcrete wearing layerBhBBase courseCCdFrost resistant sub-baseD* h = Channel height plus overhangShear reinforcement bar 10mmall 40cmDCategory according to EN 1433 / DIN V 19580Foundation: with b / thickness d / height h (in cm)The named concrete quality is a minimum qualityEN 206-1 / without danger of frost on the lateral supportDIN 1045-2 with danger of frost on the lateral supportA 15 B 125 C 250D 400** E 600 F 900 Applying to follwing channel systems:15 / 15 / * 15 / 20 / * 15 / 20 / *FASERFIX SUPER KS 100, 150, 200, 300FASERFIX SUPER 150, 200, 300, 400, 500C 30/37 XF4 C 30/37 XF4 C 30/37 XF4C 25/30 XF1 C 20/30 XF1 C 25/30 XF1The installation examples / advise constantly are adapted to the technical conditions.With new editions ol<strong>de</strong>r expenditures lose their validity.Before planning or installation please verify the current version at www.hauraton.<strong>com</strong>ECondition: 22.02.2007Our general installationinstructions apply.Surface:ConcreteE** In Class D 400 not for use across the carriagewayof highways or motorways in moving traffic. For this application were<strong>com</strong>mend our channel systems FASERFIX TRAFFIC SUPERBLOCor FASERFIX TRAFFIC GUGIBLOC12Description: FF-S-200 Typ 010_Einbau Klasse F 900 in Beton_GBDrawing-no.: C:\pdmwe\inventor\2007\05\0\0000014802.idw34 5 67hauraton | <strong>Gama</strong> <strong>de</strong> <strong>productos</strong> <strong>2009</strong> 49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!