13.07.2015 Views

Profibus DP Class 2 - TR Electronic

Profibus DP Class 2 - TR Electronic

Profibus DP Class 2 - TR Electronic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Linear transducer LA-46 PROFIBUS-<strong>DP</strong>iELEC<strong>TR</strong>ONIC GmbHEglishalde 6D-78647 TrossingenTel. +49 - (0) 74 25 / 228 - 0Fax +49 - (0) 74 25 / 228 - 33http://www.tr-electronic.deGermany• Suitable for a direct installation inhydraulic cylinders• Linear transducer exchangeable (option)• Non-contact and wear free measurementsystem• Adjustable measuring range• PROFIBUS-<strong>DP</strong>–interface• Easy mounting• Customizations upon request• Other interfaces available (Analog,DeviceNet, CANopen, SSI)7CharacteristicsMeasuring length................................................................... 50 mm – 2000 mm > 2000mm upon request, in Steps of 50 mmResolution ............................................................................. max. 0,005 mmLinearity deviation - related to the measuring length............. ±0,1mm to 1.000mm / ±0,15mm > 1.000mmRepeatability.......................................................................... ≤ 0,005 mmHysteresis.............................................................................. ≤ 0,02 mmTemperature coefficient......................................................... < 5 µm / °CMagnet velocity and mounting position ................................. no restrictionMaterial - measuring rod........................................................ Cr/Ni - alloyMagnet................................................................................... T4-M33, other upon requestPower supply......................................................................... 24 VDC -20%, +10 %Power consumption ( without load ) ...................................... < 4 WattData protocol ......................................................................... compliant DIN E 19 245 T.3Output code........................................................................... binaryBaudrate................................................................................ max. 12MbaudAddressable of ...................................................................... 3…99 stations (adjustable by switches and display)Cycle time≤ 1,0 m measuring length ............................ 1,00 ms≤ 1,5 m measuring length ............................ 1,50 ms≤ 2,0 m measuring length ............................ 2,00 msProgarmmable via PROFIBUS.............................................. PROFIBUS-<strong>DP</strong> (Protocol compliant DIN E 19 245 T.3)ResolutionCounting directionAdjustmentRod end mounting ................................................................. optionLinear transducer in the built-in condition exchangeable ...... optionConnection ............................................................................ screw clamp internal, 3 x cable gland axial03/05 Revision 01 <strong>TR</strong>-VLA-TI-GB-0418-01.DOC7 - 1Subject to change ©<strong>TR</strong>-<strong>Electronic</strong> GmbH <strong>TR</strong>-VLA-TI-GB-0418

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!