<strong>FIAMMETTA</strong> <strong>–</strong> <strong>GIORGIA</strong> <strong>–</strong> <strong>ASIA</strong> <strong>–</strong> <strong>FIORELLA</strong> <strong>–</strong> <strong>LUCY</strong><br />

2 m 10 m<br />

1<br />

m<br />

Inclination of the<br />

roof<br />

CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683/98<br />

6. CONNECTION TO THE CHIMNEY<br />

Distance between the roof<br />

ridge and the stack<br />

Minimum height of the stack<br />

(measured from the outlet)<br />

α A (m) H (m)<br />

15°<br />

30°<br />

45°<br />

60°<br />

H min.<br />

α<br />

(1) The chimney cap must not show hindrances within 10 m from<br />

walls, pitches and trees. Otherwise raise it of at least 1 m over the<br />

hindrance.<br />

The chimney cap must exceed the ridge of the roof of at least 1 m.<br />

>A<br />

< 1.85 m 0.50 m above the roof ridge<br />

> 1.85 m 1.00 m from the roof<br />

< 1.50 m 0.50 m above the roof ridge<br />

> 1.50 m 1.30 m from the roof<br />

< 1.30 m 0.50 m above the roof ridge<br />

> 1.30 m 2.00 m from the roof<br />

< 1.20 m 0.50 m above the roof ridge<br />

> 1.20 m 2.60 m from the roof<br />

Picture 6<br />

Picture 7<br />

For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the<br />

fuel or for removing the ashes, while during the operation and the rest, the door of the hearth must remain closed.<br />

The appliances with constructive system 2 must be connected to their own flue. The operating with open door is<br />

allowed under supervision.<br />

The stove is endowed with an upper exhaust pipe. The connection pipe to the flue must be the shortest possible,<br />

right, tight and according to the current regulations.<br />

The connection to the chimney must be performed with stable and strong pipes (we recommend a thickness of 2<br />

mm). The pipe for smokes exhaust must be fixed hermetically to the chimney. The diameter inside the connection<br />

> _ A<br />

(1)Ridge axis<br />

(2)Roof<br />

0,5 m<br />