FIAMMETTA - ASIA – GIORGIA – FIORELLA - LUCY
FIAMMETTA - ASIA – GIORGIA – FIORELLA - LUCY
FIAMMETTA - ASIA – GIORGIA – FIORELLA - LUCY
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>FIAMMETTA</strong> <strong>–</strong> <strong>GIORGIA</strong> <strong>–</strong> <strong>ASIA</strong> <strong>–</strong> <strong>FIORELLA</strong> <strong>–</strong> <strong>LUCY</strong><br />
2 m 10 m<br />
1<br />
m<br />
Inclination of the<br />
roof<br />
CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683/98<br />
6. CONNECTION TO THE CHIMNEY<br />
Distance between the roof<br />
ridge and the stack<br />
Minimum height of the stack<br />
(measured from the outlet)<br />
α A (m) H (m)<br />
15°<br />
30°<br />
45°<br />
60°<br />
H min.<br />
α<br />
(1) The chimney cap must not show hindrances within 10 m from<br />
walls, pitches and trees. Otherwise raise it of at least 1 m over the<br />
hindrance.<br />
The chimney cap must exceed the ridge of the roof of at least 1 m.<br />
>A<br />
< 1.85 m 0.50 m above the roof ridge<br />
> 1.85 m 1.00 m from the roof<br />
< 1.50 m 0.50 m above the roof ridge<br />
> 1.50 m 1.30 m from the roof<br />
< 1.30 m 0.50 m above the roof ridge<br />
> 1.30 m 2.00 m from the roof<br />
< 1.20 m 0.50 m above the roof ridge<br />
> 1.20 m 2.60 m from the roof<br />
Picture 6<br />
Picture 7<br />
For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the<br />
fuel or for removing the ashes, while during the operation and the rest, the door of the hearth must remain closed.<br />
The appliances with constructive system 2 must be connected to their own flue. The operating with open door is<br />
allowed under supervision.<br />
The stove is endowed with an upper exhaust pipe. The connection pipe to the flue must be the shortest possible,<br />
right, tight and according to the current regulations.<br />
The connection to the chimney must be performed with stable and strong pipes (we recommend a thickness of 2<br />
mm). The pipe for smokes exhaust must be fixed hermetically to the chimney. The diameter inside the connection<br />
> _ A<br />
(1)Ridge axis<br />
(2)Roof<br />
0,5 m<br />
7196601 <strong>–</strong> Rev.07 <strong>–</strong> EN 19