• each bend of the smoke channel considerably reduces the draught of the flue which must be compensated<br />
for by raising it suitably;<br />
• the UNI 10683-2005 Regulation <strong>–</strong>Italy requires that the bends or variations of direction must in no case be<br />
greater than 2 including the emission into the flue.<br />
Wanting to use the flue of a chimney or open furnace, it will be necessary to close the hood hermetically below the<br />
inlet point of the smoke channel pos. A Picture 9.<br />
If the flue is too large (e.g. cm 30x40 or 40x50) it is necessary to duct it with a stainless steel tube of at least 200 mm<br />
of diameter, pos. B taking care to close the space between the tube itself and the flue immediately below the chimney<br />
cap pos. C.<br />
For further information please contact your Dealer.<br />
C - Plugging<br />
A <strong>–</strong> Hermetic closure<br />
Inspection<br />
hatch<br />
Picture 9<br />