' & "<br />
Cable lengths and cross-sections<br />
12-pole plug connector<br />
Battery I positive pole<br />
Charging cable red<br />
Battery II positive pole<br />
Charging / supply cable<br />
red<br />
Battery II negative pole<br />
Charging / supply cable<br />
blue<br />
Connection<br />
Only use the specified cross-sections!<br />
For length of up to 3 m, cable cross-section 10 mm².<br />
For length of up to 6 m, cable cross-section 10 mm².<br />
Length over 6 m, cable cross section 16 mm².<br />
For length of up to 6 m, cable cross-section 10 mm².<br />
For length of up to 6 m, cable cross-section 10 mm².<br />
Disconnect the power cables from the battery<br />
and from the mains before connecting /<br />
disconnecting any cables!<br />
Connection to the control panel<br />
12-pole flat plug<br />
Plug the 12-pole flat cable into your control panel. The assignation of the<br />
contacts is according to the following list:<br />
Terminal 1 Negative connection<br />
Fig. 6: 12-pole connector<br />
Terminal 2 + Test connection for battery II<br />
Terminal 3 + Test connection for battery I<br />
Terminal 4 Control connection for user relay<br />
! "#$ %&&<br />
35<br />
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: +49(0)8341 / 9764-0 Fax: +49(0)8341 / 67806