K168<br />
Etude d’une installation<br />
Sélectivité <strong>des</strong> protections<br />
<strong>Tableau</strong>x de sélectivité<br />
Amont : NS800 à 1000L, NS1600b à 3200N<br />
Aval : Multi 9, NS125E, NSA160N,<br />
NS100 à 250<br />
Amont NS800/NS1000L NS1600b/NS2000/ NS1600b/NS2000/NS2500/<br />
NS2500/NS3200N<br />
NS3200N - Inst : OFF<br />
Décl. Micrologic 5.0 - 7.0 - Inst : OFF Micrologic 2.0 - Isd : 10 Ir Micrologic 5.0 - 7.0<br />
Calibre (A) 800 800 1000 1600 2000 2500 3200 1600 2000 2500 3200<br />
Aval Réglage Ir 320 400 500 630 800 1000 1600 2000 2500 3200 1600 2000 2500 3200<br />
DT40, XC40, C60 T T T T T T T T T T T T T T<br />
C120, NG125 T T T T T T T T T T T T T T<br />
NS125E y 25 T T T T T T T T T T T T T T<br />
Décl. TM-D 40 T T T T T T T T T T T T T T<br />
63 T T T T T T T T T T T T T T<br />
80 T T T T T T T T T T T T T T<br />
100 T T T T T T T T T T T T T T<br />
125 T T T T T T T T T T T T T T<br />
NSA160N 63 T T T T T T T T T T T T T T<br />
80 T T T T T T T T T T T T T T<br />
100 T T T T T T T T T T T T T T<br />
125 T T T T T T T T T T T T T T<br />
160 T T T T T T T T T T T T T<br />
NS100N 16 T T T T T T T T T T T T T T<br />
Décl. TM-D 25 T T T T T T T T T T T T T T<br />
32 T T T T T T T T T T T T T T<br />
40 T T T T T T T T T T T T T T<br />
50 T T T T T T T T T T T T T T<br />
63 T T T T T T T T T T T T T T<br />
80 T T T T T T T T T T T T T T<br />
100 T T T T T T T T T T T T T T<br />
NS100H/L 16 T T T T T T T T T T T T T T<br />
Décl. TM-D 25 T T T T T T T T T T T T T T<br />
32 T T T T T T T T T T T T T T<br />
40 T T T T T T T T T T T T T T<br />
50 T T T T T T T T T T T T T T<br />
63 T T T T T T T T T T T T T T<br />
80 T T T T T T T T T T T T T T<br />
100 T T T T T T T T T T T T T T<br />
NS160N y 63 T T T T T T T T T T T T T T<br />
Décl. TM-D 80 T T T T T T T T T T T T T T<br />
100 T T T T T T T T T T T T T T<br />
125 T T T T T T T T T T T T T T<br />
160 T T T T T T T T T T T T T<br />
NS160H/L y 63 T T T T T T T T T T T T T T<br />
Décl. TM-D 80 T T T T T T T T T T T T T T<br />
100 T T T T T T T T T T T T T T<br />
125 T T T T T T T T T T T T T T<br />
160 T T T T T T T T T T T T T<br />
NS250N y 100 T T T T T T T T T T T T T T<br />
Décl. TM-D 125 T T T T T T T T T T T T T T<br />
160 T T T T T T T T T T T T T<br />
200 T T T T T T T T T T T T<br />
250 T T T T T T T T T T T<br />
NS250H/L y 100 T T T T T T T T T T T T T T<br />
Décl. TM-D 125 T T T T T T T T T T T T T T<br />
160 T T T T T T T T T T T T T<br />
200 T T T T T T T T T T T T<br />
250 T T T T T T T T T T T<br />
NS100N 40 T T T T T T T T T T T T T T<br />
STR22SE 100 T T T T T T T T T T T T T T<br />
NS100H/L 40 T T T T T T T T T T T T T T<br />
STR22SE 100 T T T T T T T T T T T T T T<br />
NS160N 40 T T T T T T T T T T T T T T<br />
STR22SE 80 T T T T T T T T T T T T T T<br />
100 T T T T T T T T T T T T T T<br />
160 T T T T T T T T T T T T T T<br />
NS160H/L 40 T T T T T T T T T T T T T T<br />
STR22SE 100 T T T T T T T T T T T T T T<br />
160 T T T T T T T T T T T T T T<br />
NS250N y 100 T T T T T T T T T T T T T T<br />
STR22SE 160 T T T T T T T T T T T T T T<br />
250 T T T T T T T T T T T T<br />
NS250H/L y 100 T T T T T T T T T T T T T T<br />
STR22SE 160 T T T T T T T T T T T T T T<br />
250 T T T T T T T T T T T T T<br />
<strong>Schneider</strong> <strong>Electric</strong> - Catalogue distribution électrique 2002