gets <strong>in</strong>to the device, remove the battery immediately. Only use the<br />

device aga<strong>in</strong> when it is completely dry.<br />

Do not use any harsh clean<strong>in</strong>g agents.<br />

Never immerse the device <strong>in</strong> water.<br />

Always store the thermometer with the cap on <strong>in</strong> order to protect the<br />

sensor.<br />

The device must not be stored or used at too high or low a temperature<br />

or humidity (see technical specifications), <strong>in</strong> sunlight, <strong>in</strong> association<br />

with an electrical current or <strong>in</strong> dusty locations. Otherwise,<br />

<strong>in</strong>accuracies can occur.<br />

If prolonged storage is <strong>in</strong>tended, you should remove the battery.<br />

The device must be tested for accuracy (calibrated) after 3 years.<br />

Please send the complete device to the dealer’s or service address.<br />

Please dispose of the device <strong>in</strong> accordance with the directive<br />

2002/96/EG – WEEE (Waste Electrical and Electronic<br />

Equipment). If you have any queries, please refer to the local<br />

authorities responsible for waste disposal.<br />

9. Technical data<br />

Note: When the device is used outside the specifications, perfect<br />

function<strong>in</strong>g cannot be guaranteed.<br />

We reserve the right to make technical changes to improve and<br />

develop the product.<br />

Name and model<br />

SFT41<br />

Measurement range Forehead thermometer mode: 34 °C to 42,2 °C<br />

(93,2 °F to 108 °F)<br />

SCAN mode: -22 °C – 80 °C (-7,6 °F – 176 °F)<br />

Laboratory measurement<br />

precision<br />

Interval between 2<br />

measurements<br />

Measurement units<br />

Operat<strong>in</strong>g conditions<br />

Forehead thermometer mode: ±0,3 °C (±0,5 °F)<br />

from 34 °C to 42,2°C (93,2 °F to 108 °F)<br />

SCAN-Modus: ±0,3 °C from 22 °C to 42,2 °C<br />

(71,6 °F to 108 °F)<br />

±2 °C with >42,2 °C and 108 °F,<br />