send out its first pulse after receiving the command to reactivate.<br />

Ensure that the symbol for low battery charge ( ) is not displayed on the remote control<br />

display. If the symbol is illuminated or blinking, replace the 9 V alkaline battery and try<br />

again.<br />

Ensure that the remote contact, on the face of the remote control, is used to send ON and OFF<br />

signals.<br />

Rusty or oxidised wire can hamper the quality of the signal you receive. To obtain a clear<br />

signal, rub the remote contact against the fence wire to break through the layer of rust or oxidation.<br />

Ensure that no spring gates or cut­out switches have been left open. Sometimes the remote<br />

control will work in spite of minor breaks in the wire, although reliable operation under such<br />

conditions is not guaranteed.<br />

Check for spark gaps and loose wire joints in the fence. Severe or multiple spark gaps reduce<br />

the effectiveness of the remote control.<br />

Use the fault finding function to locate faults in the fence line. See “Using the fault finder” on<br />

page 47.<br />

Ensure that the energiser is connected to the power supply and the fence system and that the<br />

energiser is switched on. Ensure a good earthing system for the energiser.<br />

Try turning the energiser on and off by holding the remote contact against the lead­out wire,<br />

or by holding the remote control close to the energiser (within 150 to 300 mm [6 to 12”]). If<br />

the energiser still does not respond, then the remote control and energiser may have different<br />

address settings. See “changing the energiser’s address settings” on page 50 and “Activating<br />

the remote control function of a remote ready energiser” on page 51.<br />

The energiser sometimes turns off unexpectedly<br />

An adjacent property may have an energiser operating at the same address setting. Change<br />

the energiser’s address setting. See “Changing the energiser’s address settings” on page 50. If<br />

the problem persists, seek advice from your PATURA distributor.<br />