08.12.2012 Views

EC Declaration of Conformity - Itron

EC Declaration of Conformity - Itron

EC Declaration of Conformity - Itron

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ANNEX 3: Installation <strong>of</strong> the Cyble sensor<br />

1) Mounting 2) Screwing (Max torque: 0,25 Nm) 3) Sealing<br />

ANNEX 4: Transmitters characteristics and plugging<br />

Unless on the nameplate noted the following electrical parameter shall be considered:<br />

Low Frequency transmitters (LF):<br />

1) Internal Reed contacts characteristics<br />

• Hermetically sealed contacts<br />

42<br />

- Maximum terminal voltage: 30 Volt and maximum<br />

current according to EN 60079-11.<br />

• Ambient temperature Ta= -30°C to +60°C<br />

• Minimum pulse time: 0,4 s<br />

2) Cyble sensor<br />

• It conforms to CENEL<strong>EC</strong> standard EN 60079-<br />

11 with:<br />

- Ui ≤ 14,3 Volt<br />

- Ii ≤ 50 mA<br />

Inductive transmitters:<br />

1) High Frequency transmitters characteristics<br />

• Proximity detectors conform to 60947-5-6<br />

(NAMUR) standards.<br />

• They conform to CENEL<strong>EC</strong> standards (EN<br />

60079-0 and EN 60079-11) with:<br />

- Ui ≤ 15 Volt<br />

- Ii ≤ 50 mA<br />

- Ci ≤ 90 ηF<br />

- Li ≤ 100 μH<br />

- Pi ≤ 120 mW<br />

• Ambient temperature Ta= -30°C to +60°C<br />

2) Medium Frequency transmitter<br />

• It conforms to CENEL<strong>EC</strong> standards (EN<br />

60079-0 and EN 60079-11) with:<br />

- Ui ≤ 16 Volt<br />

- Ii ≤ 52 mA<br />

- Ci ≤ 50 ηF<br />

- Li ≤ 250 μH<br />

- Pi ≤ 64 mW<br />

Plugging <strong>of</strong> the meter (extern view <strong>of</strong> the socket installed on the meter)<br />

LF, MF HF<br />

DIN45322 DIN41524

Hooray! Your file is uploaded and ready to be published.