CONSOLE - R 407C TECHNICAL DATA<br />

Unit size OEDA-UEDA 110 150 170<br />

Total cooling capacity(1) kW 10,4 13,8 16,5<br />

Sensible capacity (1) kW 10,2 13,7 15,9<br />

No. of fans N° 2 3 3<br />

<strong>Air</strong> flow m 3 /s 0,889 1,361 1,361<br />

Residual pressure Pa 50 50 50<br />

Engaged power kW 0,5 0,75 0,75<br />

No. of fans N° 1 1 1<br />

Engaged power kW 2,4 3,2 3,9<br />

In combination with remote air condensers<br />

CRAX axial fans<br />

Quantity n° 1 1 1<br />

Ambient air temp. 40°C Mod. 14 17 17<br />

Ambient air temp. 45°C Mod. 30 30 41<br />

CRCF centrifugal fans<br />

Quantity n° 1 1 1<br />

Ambient air temp. 40°C Mod. 10 10 15<br />

Ambient air temp. 45°C Mod. 25 40 40<br />

Unit size OEDW-UEDW 110 150 170<br />

Total cooling capacity(2) kW 11,3 15 17,8<br />

Sensible capacity (2) kW 10,6 14,9 16,5<br />

No. of fans N° 2 3 3<br />

<strong>Air</strong> flow m 3 /s 0,889 1,361 1,361<br />

External static pressure Pa 50 50 50<br />

Engaged power kW 0,75 0,75 0,75<br />

No. of fans N° 1 1 1<br />

Engaged power kW 2,0 2,8 3,4<br />

<strong>AIR</strong> BLUE<br />

Unit size OEDR-UEDR 110 150 170<br />

Total cooling capacity(3) kW 10,7 14,1 16,9<br />

Sensible capacity (3) kW 10,3 14,0 16,1<br />

No. of fans N° 2 3 3<br />

<strong>Air</strong> flow m 3 /s 0,889 1,361 1,361<br />

External static pressure Pa 50 50 50<br />

Engaged power kW 0,5 0,75 0,75<br />

No. of compressors N° 1 1 1<br />

Engaged power kW 2,3 3,1 3,8<br />

In combination with remote air-cooled liquid chillers<br />

RAC axial fans<br />

Quantity n° 1 1 1<br />

Ambient air temp. 32°C Mod. 14 22 22<br />

Unit size OFC-UFC 110 170<br />

Total cooling capacity(4) kW 12,0 19,5<br />

Sensible capacity(4) kW 10,8 17,5<br />

No. of fans N° 2 3<br />

<strong>Air</strong> flow m 3 /s 0,889 1,361<br />

Residual pressure Pa 50 50<br />

Engaged power kW 0,5 0,75<br />

(1) Characteristics refer to 24 °C inlet air with 50% RH.<strong>Air</strong> to condenser 32 °C.<br />

(2) Charact. refer to 24 °C inlet air with 50% RH. Condenser water inlet 15 °C.<br />

(3) Charact. refer to 24 °C inlet air with 50% RH.Water to condenser 35/40 °C.<br />

(4) Characteristics refer to 24 °C inlet air with 50% RH.<br />

Supply voltage: 400-3+N-50<br />