P-<strong>touch</strong> Template Command Refe<strong>rence</strong><br />

^RC<br />

Specify line feed command text string<br />

ASCII: ^ R C n1 n2 data<br />

Decimal: 94 82 67 n1 n2 data<br />

Hexadecimal: 5E 52 43 n1 n2 data<br />

Parameters<br />

0≤n1≤2<br />

0≤n2≤9<br />

00h≤data≤FFh<br />

Description<br />

• Specifies the text string for the line feed command.<br />

(n1*10)+n2: Length of the text string (can be set between 1 and 20)<br />

data: Text string (The maximum number of characters that can be set is 20 characters (bytes).)<br />

• The default text string for the line feed command is “^CR”.<br />

• This command is a dynamic command.<br />

Remarks<br />

• Invalid if more than 20 characters have been specified<br />

Example<br />

• To change the text string for the line feed command to “0Dh 0Ah”:<br />

Since the text string to be specified (data) contains 2 characters, n1=0 and n2=2. Therefore, the<br />

command will be as follows.<br />

^ R C 0 2 0Dh 0Ah<br />

(5Eh 52h 43h 30h 32h 0Dh 0Ah)<br />