1.0 PARTS SUPPLIED<br />
Shower mixer<br />
Pre-installation set 35.005.970.90<br />
1 x concealed mixer cartridge in polystyrene block<br />
1 x cartridge retainer<br />
1 x EHM cartridge 03.15.05.020.00.90<br />
1 x head connection<br />
1 x plug for outlet 1/2”<br />
2 x preliminary check valves with conical seal in cold<br />
and hot water inlets<br />
2 x protective caps against unintended unscrewing<br />
of preliminary check valves<br />
1 x threaded connection 1/2”<br />
2 x inserted mufflers in the connections cold - hot.<br />
Screwing depth for inlets 12 mm<br />
2 x fasteners M 5 x 100<br />
Bath/ shower mixer<br />
Pre-installation set 35.105.970.90<br />
1 x concealed mixer cartridge in polystyrene block<br />
1 x cartridge retainer<br />
1 x EHM cartridge 03.15.05.020.00.90<br />
1 x head connection<br />
2 x preliminary check valves with conical seal in cold<br />
and hot water inlets<br />
2 x protective caps against unintended unscrewing<br />
of preliminary check valves<br />
2 x threaded connection 1/2”<br />
2 x inserted mufflers in the connections cold - hot.<br />
Screwing depth for inlets 12 mm<br />
1 x automatic diverter bath - shower<br />
2 x fasteners M 5 x 100<br />
Shower mixer<br />
Final installation set 36.000. ...<br />
1 x covering plate with profile seal and sealing strip<br />
1 x covering rosette<br />
1 x lever<br />
1 x set screw M 5 x 10<br />
2 x ornamental caps<br />
Bath/ shower mixer<br />
Final installation set 36.100. ...<br />
1 x covering plate with profile seal and sealing strip<br />
1 x covering rosette<br />
1 x lever<br />
1 x set screw M 5 x 10<br />
1 x sleeve for diverter<br />
1 x draw bar for diverter, compl.<br />
2 x ornamental caps<br />
Design elements not part of delivery!<br />
2.0 OPERATING CONDITIONS<br />
Recommended flow temperature 65°C<br />
Maximum flow temperature 80°C<br />
Minimum flow pressure 1 bar<br />
Maximum flow pressure 10 bar<br />
Recommended operating pressure 1 - 5 bar<br />
Test pressure 16 bar<br />
Holding pressure for diverter min.0.8 bar<br />
Noise classification 1, as per DIN 4109.<br />
With off-load pressures over 5 bar it is<br />
recommended that a pressure reducing valve<br />
as per DIN 1988 is installed in the inlet pipes.<br />
ATTENTION These fittings are not suitable<br />
for use with pressureless hot water boilers.<br />
An extensive balancing of the volume flow (L output)<br />
Hot-Cold should be carried out where flow heaters<br />
are used. See 6.0<br />
Please note the manufacturer’s guidelines!<br />
DIN 1988 must be followed where pipes have been<br />
newly installed!<br />
3.0 PRE-INSTALLATION<br />
Please refer to the scale drawings for sizes and<br />
installation depth.<br />
1/2” connections<br />
Min. installation depth – measured from centre<br />
connection to forward edge tile – 40 mm.<br />
Max. installation depth –<br />
without extension – 55 mm.<br />
Adjustability 15 mm<br />
Please read the instructions on the polystyrene<br />
block and the strip carefully! See Fig. 1<br />
Hot water connection left, cold water<br />
connection right.<br />
Where a diverter is fitted, connect the largest consumer<br />
(bath, overhead shower) to the lower outlet.<br />
See Fig. 2<br />
ATTENTION The tiles must sit flush with the<br />
polystyrene block so that optimal cover from<br />
the covering plate is guaranteed!<br />
Installation opening max. 120 mm wide.<br />
See Fig. 3<br />
Fig. 1<br />
Fig. 2<br />
Fig. 3<br />
GB