13.09.2013 Views

MONTAGEANLEITUNG

MONTAGEANLEITUNG

MONTAGEANLEITUNG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Brause<br />

shower<br />

Stopfen<br />

plug<br />

kalt<br />

cold<br />

warm<br />

hot<br />

Brause<br />

shower<br />

Wanne<br />

tub<br />

kalt<br />

cold<br />

warm<br />

hot<br />

136<br />

206<br />

37<br />

37<br />

11<br />

35.005.970.90<br />

G1/2<br />

G1/2<br />

G1/2<br />

160<br />

90<br />

40 15<br />

G1/2<br />

35.105.970.90<br />

160<br />

90<br />

40 15<br />

G1/2<br />

G1/2<br />

42<br />

42<br />

125 135<br />

206<br />

G1/2<br />

G1/2<br />

120<br />

135<br />

120<br />

1.0 PARTS SUPPLIED<br />

Shower mixer<br />

Pre-installation set 35.005.970.90<br />

1 x concealed mixer cartridge in polystyrene block<br />

1 x cartridge retainer<br />

1 x EHM cartridge 03.15.05.020.00.90<br />

1 x head connection<br />

1 x plug for outlet 1/2”<br />

2 x preliminary check valves with conical seal in cold<br />

and hot water inlets<br />

2 x protective caps against unintended unscrewing<br />

of preliminary check valves<br />

1 x threaded connection 1/2”<br />

2 x inserted mufflers in the connections cold - hot.<br />

Screwing depth for inlets 12 mm<br />

2 x fasteners M 5 x 100<br />

Bath/ shower mixer<br />

Pre-installation set 35.105.970.90<br />

1 x concealed mixer cartridge in polystyrene block<br />

1 x cartridge retainer<br />

1 x EHM cartridge 03.15.05.020.00.90<br />

1 x head connection<br />

2 x preliminary check valves with conical seal in cold<br />

and hot water inlets<br />

2 x protective caps against unintended unscrewing<br />

of preliminary check valves<br />

2 x threaded connection 1/2”<br />

2 x inserted mufflers in the connections cold - hot.<br />

Screwing depth for inlets 12 mm<br />

1 x automatic diverter bath - shower<br />

2 x fasteners M 5 x 100<br />

Shower mixer<br />

Final installation set 36.000. ...<br />

1 x covering plate with profile seal and sealing strip<br />

1 x covering rosette<br />

1 x lever<br />

1 x set screw M 5 x 10<br />

2 x ornamental caps<br />

Bath/ shower mixer<br />

Final installation set 36.100. ...<br />

1 x covering plate with profile seal and sealing strip<br />

1 x covering rosette<br />

1 x lever<br />

1 x set screw M 5 x 10<br />

1 x sleeve for diverter<br />

1 x draw bar for diverter, compl.<br />

2 x ornamental caps<br />

Design elements not part of delivery!<br />

2.0 OPERATING CONDITIONS<br />

Recommended flow temperature 65°C<br />

Maximum flow temperature 80°C<br />

Minimum flow pressure 1 bar<br />

Maximum flow pressure 10 bar<br />

Recommended operating pressure 1 - 5 bar<br />

Test pressure 16 bar<br />

Holding pressure for diverter min.0.8 bar<br />

Noise classification 1, as per DIN 4109.<br />

With off-load pressures over 5 bar it is<br />

recommended that a pressure reducing valve<br />

as per DIN 1988 is installed in the inlet pipes.<br />

ATTENTION These fittings are not suitable<br />

for use with pressureless hot water boilers.<br />

An extensive balancing of the volume flow (L output)<br />

Hot-Cold should be carried out where flow heaters<br />

are used. See 6.0<br />

Please note the manufacturer’s guidelines!<br />

DIN 1988 must be followed where pipes have been<br />

newly installed!<br />

3.0 PRE-INSTALLATION<br />

Please refer to the scale drawings for sizes and<br />

installation depth.<br />

1/2” connections<br />

Min. installation depth – measured from centre<br />

connection to forward edge tile – 40 mm.<br />

Max. installation depth –<br />

without extension – 55 mm.<br />

Adjustability 15 mm<br />

Please read the instructions on the polystyrene<br />

block and the strip carefully! See Fig. 1<br />

Hot water connection left, cold water<br />

connection right.<br />

Where a diverter is fitted, connect the largest consumer<br />

(bath, overhead shower) to the lower outlet.<br />

See Fig. 2<br />

ATTENTION The tiles must sit flush with the<br />

polystyrene block so that optimal cover from<br />

the covering plate is guaranteed!<br />

Installation opening max. 120 mm wide.<br />

See Fig. 3<br />

Fig. 1<br />

Fig. 2<br />

Fig. 3<br />

GB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!