05.11.2014 Views

DATA LOGGER MANUALE D'USO BASIC - ADVANCED - Santerno

DATA LOGGER MANUALE D'USO BASIC - ADVANCED - Santerno

DATA LOGGER MANUALE D'USO BASIC - ADVANCED - Santerno

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MANUALE</strong> <strong>BASIC</strong> - <strong>ADVANCED</strong><br />

DI PROGRAMMAZIONE<br />

<strong>DATA</strong> <strong>LOGGER</strong><br />

ES851<br />

8. MENÙ LOG MONITOR<br />

Le misure relative allo stato dei Log sono suddivise in 6 menù: “LOG1 MONITOR”, “LOG2 MONITOR”, “LOG3<br />

MONITOR”, “LOG4 MONITOR”, “LOG5 MONITOR”, “LOG6 MONITOR”.<br />

Parametro FUNZIONE Livello di Accesso Indirizzo MODBUS<br />

M5050, M5051,<br />

M5052, M5053,<br />

M5054, M5055<br />

M5057, M5058,<br />

M5059, M5060,<br />

M5061, M5062<br />

M5070a-b, M5073a-b,<br />

M5076a-b, M5079a-b,<br />

M5082a-b, M5085a-b<br />

M5071a-b, M5074a-b,<br />

M5077a-b, M5080a-b,<br />

M5083a-b, M5086a-b<br />

M5072a-b, M5075a-b,<br />

M5078a-b, M5081a-b,<br />

M5084a-b, M5087a-b<br />

Lunghezza Log<br />

Stato Log<br />

Anno e mese di attivazione log<br />

Giorno e ora di attivazione log<br />

Minuti e secondi di attivazione log<br />

Tabella 16: Elenco misure di Log Monitor<br />

<strong>BASIC</strong><br />

<strong>BASIC</strong><br />

<strong>BASIC</strong><br />

<strong>BASIC</strong><br />

<strong>BASIC</strong><br />

5050, 5051, 5052,<br />

5053, 5054, 5055<br />

5057, 5058, 5059,<br />

5060, 5061, 5062<br />

5070, 5073, 5076,<br />

5079, 5082, 5085<br />

5071, 5074, 5077,<br />

5080, 5083, 5086<br />

5072, 5075, 5078,<br />

5081, 5084, 5087<br />

M5050 (M051, M5052, M5053, M5054, M5055) Lunghezza Log<br />

M5050 (log 1)<br />

M5051 (log 2)<br />

M5052 (log 3)<br />

M5053 (log 4)<br />

M5054 (log 5)<br />

M5055 (log 6)<br />

Lunghezza Log<br />

Range 0 ÷ 2000 0 ÷ 2000 Kbyte<br />

Level <strong>BASIC</strong><br />

Address 5050, 5051, 5052, 5053, 5054, 5055<br />

Function Lunghezza dei dati memorizzati in FLASH CARD per ogni log in kbyte<br />

M5057 (M5058, M5059, M5060, M5061, M5062) Stato Log<br />

M5057 (log 1)<br />

M5058 (log 2)<br />

M5059 (log 3)<br />

M5060 (log 4)<br />

M5061 (log 5)<br />

M5062 (log 6)<br />

Stato Log<br />

Range Misura gestita a bit Vedi Tabella 17<br />

Level <strong>BASIC</strong><br />

Address 5057, 5058, 5059, 5060, 5061, 5062<br />

Function Stato corrente del Log<br />

34/66