CENTRALI DI TERMOREGOLAZIONE<br />

: CLIMATIC CONTROL UNIT<br />

Centralina di termoregolazione climatica<br />

Electronic controller of heating plants<br />

RE200<br />

<br />

zionale/integrativa con comando modulante per valvole<br />

<br />

per consenso bruciatore.<br />

Adatta per impianti centralizzati, per comandare e<br />

<br />

semplicissima centralina di termoregolazione con la<br />

stessa concezione dei suoi cronotermostati.<br />

<br />

è subito fatta.<br />

L’evoluzione della centralina "RE150" è la nuova centralina<br />

<br />

<br />

<br />

<br />

<br />

di riscaldamento a seconda della temperatura esterna<br />

all’ambiente. Le temperature esterne sono naturalmente<br />

rilevate da apposite sonde che indicheranno i valori<br />

<br />

temperatura di mandata in funzione della temperatura<br />

rilevata esternamente.<br />

<br />

<br />

Thermoregulation climatic with action proportional/integrative<br />

with modulating for motorized valves 3/4 ways,<br />

pump command and auxiliary contact for burner permission.<br />

Suitable for centralized heating systems, to control and<br />

program thermal flows, GECA has engineered a very<br />

simple thermoregulation control unit with the same<br />

concept of its chrono-thermostats. A big display and only<br />

four keys: and the programming is already done.<br />

The evolution of control unit "RE150" is the new control<br />

unit "RE200 " completely digital with climatic compensation<br />

function; modular regulation with characteristic of<br />

integrative proportional to control mixing valves or burner.<br />

The control unit simply regulate the inlet water temperature<br />

in relation to the external ambient temperature. The<br />

external temperatures are normally detected by special<br />

probes indicating the values detected to the control unit<br />

which modify the inlet water temperature proportionally to<br />

the external temperature.<br />

<br />

External probe input PT1000 (2wires)<br />

<br />

Outlet probe input PT1000( 2wires)<br />

<br />

Normally closed safety thermostat input<br />

<br />

Room thermostat input<br />

<br />

Backlight graphic display for a guided user-friendly programming<br />

<br />

Perpetual calendar, automatic update for summer/usual time and 5 years power reserve<br />

<br />

<br />

Possibility to select 5 heating elements (radiators, heaters, radiant panels) for domestic ambient, radiant panels for industrial ambient<br />

ambient, outdoor radiant panels) with automatic set, within the limits og inlet temperature.<br />

<br />

Regulation curve setting according to the external temperature and the inlet temperature<br />

<br />

Possibility to set 4 program: permanent no frost, permanent economy, permanent comfort, automatic.<br />

<br />

Output relay for circulation pump <br />

<br />

Output relay for burner permission: 5A 230Vac<br />

<br />

Output relay for3/4 ways motorized valve (resistive load)<br />

<br />

Functioning temperature : 5-50°C<br />

Grado di protezione<br />

Protection range : IP 40<br />

<br />

Installation : On 9 modules DIN rail<br />

(Cod.33651043)<br />