TROUBLESHOOTINGUKEffect“Status” LED colour: Green“Status” LED colour: Orange“Status” LED colour: Red“Comm” LED colour: OrangeMessages on UCF 300displayPROGRAM MISSINGTABLES NOT FOUNDOUT BW EXCEEDEDHW FAILLURELCN REPEATEDCauseOK.There are no tables in the inputOutput Service disappearedfrom transponderNo RF outputImage pixilationHardware failureWaiting control dataService not foundDefective Input SignalImage pixilationHardware failureLCN repeatedActionCheck input cable and DVB - ASI conectionsCheck OUTPUT SERVICES list; Read Services and check if anyprogram disappearedCheck if OUTPUT RF is “YES"Check if Output Mux BW(%) is lower than 92%.(OUTPUT SERVICES)Switch OFF and ON againCheck Communication Bus between Modules andMCU <strong>8000</strong>. OK if there is no MCU <strong>8000</strong> unitRead Services in OUTPUT SERVICESCheck input cable and DVB - ASI conectionsCheck if Output Mux BW(%) is lower than 92%.(OUTPUT SERVICES)Switch OFF and ON againCheck LCN repetition on active services14