Battery powered energizer installation instructions - Gallagher.eu
Battery powered energizer installation instructions - Gallagher.eu
Battery powered energizer installation instructions - Gallagher.eu
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
English<br />
10<br />
2. Connect to earth system:<br />
Using Lead-out Cable G6270 remove 5cm (2”) of plastic coating from one end of<br />
the cable and attach to the green terminal on the <strong>energizer</strong>. Attach the cable to<br />
the earth system by removing 10cm (4”) of insulation from the cable at each Earth<br />
Stake, then clamp the exposed wire to each stake using an Earth Clamp G8760.<br />
Tighten the clamp.<br />
For maximum performance from your <strong>energizer</strong>, the earth (ground) system must<br />
be correctly installed. Use 3 galvanised earth pegs (G619). Earth pegs, at least 2<br />
metres (6½ft) long, should be spaced 3 metres (10ft) apart.<br />
For further <strong>instructions</strong> on the earth system see “How to install earth system”<br />
section.<br />
3. Connect the fence<br />
Connect <strong>energizer</strong>’s red terminal to the fence using Leadout<br />
Cable G6270: remove 5cm (2”) of plastic coating from<br />
one end of the cable and attach to the red terminal on the<br />
<strong>energizer</strong>. Attach the other end of the cable to the fence<br />
using a Joint Clamp G6030.<br />
For <strong>instructions</strong> on fence <strong>installation</strong> refer to “How to<br />
install the fence” section.<br />
4. Connect the battery<br />
Connect the battery leads from the <strong>energizer</strong> to the<br />
battery: red lead to the (+) terminal of battery, black<br />
lead to the (-) terminal of battery. Use external 12V deep<br />
cycle lead acid rechargeable battery. Do not use nonrechargeable<br />
batteries.<br />
During charging, place lead acid batteries in a well-ventilated area.<br />
WARNING: For B75, this turns the <strong>energizer</strong> on.<br />
When battery is flat (voltage drops to approx. 11.5V), the <strong>energizer</strong> slows to half<br />
speed to conserve power.<br />
Use external 12V deep cycle rechargeable battery (marine type).<br />
<strong>Battery</strong> life (using one fully charged 12v 60 ampere hour battery)<br />
High Power/Standard Pulse<br />
(Days)<br />
Low Power/Maximum<br />
Save mode (Days)<br />
B75 34 -<br />
B160 15 50<br />
B260 10 30<br />
To<br />
battery<br />
Green<br />
To<br />
earth<br />
For Solar Systems test the battery every 12 months because rechargeable<br />
batteries can lose storage capacity over time.<br />
Red<br />
To<br />
fence