<strong>ETAP</strong> SAFETY MANAGER (ESM): TRÅDBUNDEN/TRÅDLÖS<br />

BUS anslutning<br />

armaturer<br />

+ -<br />

+ -<br />

Tx<br />

Rx<br />

Gnd<br />

PC<br />

B<br />

230V 50Hz<br />

<strong>ETAP</strong><br />

BUS ADAPTER<br />

21,3 mm<br />

43,3 mm<br />

K4H16<br />

A<br />

V+<br />

Tx Gnd<br />

Rx<br />

80 mm<br />

status<br />

com xmt<br />

bus xmt<br />

power<br />

60<br />

160<br />

110<br />

V+<br />

Tx Gnd<br />

Rx<br />

FROM COM. PORT SHORT OR<br />

OR PREV. ADAPTER TO NEXT-<br />

ADAPTER<br />

A > B MAX. 8M bus<br />

Koordinator<br />

trådlös kommunikation<br />

52 mm<br />

63 mm<br />

75,2 mm<br />

BUS<br />

130<br />

112<br />

L N<br />

230V<br />

25 mm<br />

Tx<br />

Rx<br />

Gnd<br />

PC<br />

B<br />

230V<br />

50Hz<br />

230V 50Hz<br />

<strong>ETAP</strong><br />

K4H16<br />

BUS ADAPTER<br />

V+<br />

Tx Gnd<br />

Rx<br />

230 VAC<br />

1 3<br />

status<br />

com xmt<br />

bus xmt<br />

power<br />

V+<br />

Tx Gnd<br />

Rx<br />

FROM COM. PORT SHORT OR<br />

OR PREV. ADAPTER TO NEXT-<br />

ADAPTER<br />

A > B MAX. 8M first bus<br />

E TA P<br />

DA-EM Gateway<br />

2 4<br />

USB to RS-232/422/485<br />

ND-6530 Converter<br />

TX +/D+<br />

T X -/D-<br />

RX +<br />

RX -<br />

TX<br />

RX<br />

RTS<br />

CT S<br />

FGND<br />

FAULT<br />

XMT<br />

DA<br />

POWER<br />

XMT<br />

ESM<br />

POWER<br />

230V 50Hz<br />

<strong>ETAP</strong> K4H16 status<br />

com xmt<br />

bus xmt<br />

<strong>ETAP</strong> K4H16<br />

power<br />

BUS ADAPTER<br />

BUS ADAPTER<br />

V+<br />

Tx Gnd<br />

Rx<br />

FROM COM. PORT SHORT OR<br />

OR PREV. ADAPTER TO NEXT-<br />

ADAPTER<br />

intermediate bus<br />

27 29<br />

KH6<br />

30 32 34<br />

+<br />

20<br />

RL4 CO M<br />

RL4 NC<br />

RL4 NO<br />

RL3 CO M<br />

RL3 NC<br />

RL3 NO<br />

RL2 CO M<br />

RL2 NO<br />

RL1 CO M<br />

RL1 NO<br />

11<br />

-<br />

Relay Output<br />

Digital Input<br />

ND-6060<br />

Type Channels<br />

Relay Output 4<br />

Digital Input 4<br />

1<br />

DI 3<br />

DI 2<br />

DI 1<br />

DI 0<br />

Ext24V<br />

DEFAULT*<br />

(Y)DATA+<br />

(G)DATA-<br />

(R) +V s<br />

(B)GND<br />

10<br />

BUS adapter K4H16 Anslutning flera BUS adapter<br />

ethernet connection<br />

RJ45 (10/100Mbps)<br />

BUS 1<br />

(max. 500 armaturer)<br />

USB<br />

V+<br />

Tx Gnd<br />

Rx<br />

BUS 2<br />

(max. 500 armaturer)<br />

Com - Server EUG<br />

power supply<br />

(12-48 VDC)<br />

RS232<br />

from BUS-adapter<br />

ESM BUS<br />

Voltfri kontakt<br />

230 VAC<br />

1 3<br />

E TA P<br />

230V 50Hz<br />

A<br />

FROM COM. PORT SHORT OR<br />

OR PREV. ADAPTER TO NEXT-<br />

ADAPTER<br />

last bus<br />

DALI POWER SUPPLY<br />

BUS power supply K4H12<br />

230V 50Hz<br />

E TA P<br />

overload<br />

K4H12<br />

xmt<br />

power<br />

BUS POWER SUPPLY<br />

V+<br />

Tx Gnd<br />

Rx<br />

status<br />

com xmt<br />

bus xmt<br />

power<br />

V+<br />

Tx Gnd<br />

Rx<br />

OVERLOAD<br />

XMT<br />

POWER<br />

bus<br />

BUS 3<br />

(max. 500 armaturer)<br />

DALI nödjljusenhet segment<br />

+<br />

KH7<br />

32 34<br />

-<br />

<strong>NÖDBELYSNING</strong>