CONTEÚDO:<br />

GUIA RÁPIDO DE CONFIGURAÇÃO PROFIBUS PARA MODICON PREMIUM<br />

(TSXPBY100) E <strong>ATV71</strong><br />

A) DIAGRAMA DA REDE<br />

B) CONFIGURAÇÃO DA REDE PROFIBUS ATRAVÉS DO SYCON;<br />

C) IMPORTANDO E DEFININDO ENDEREÇOS NO UNITY;<br />

D) PARAMETRIZAÇÃO DO <strong>ATV71</strong>.<br />

A) DIAGRAMA DA REDE<br />

PREMIUM + TSXPBY100<br />

490NAD91103<br />

LEGENDA<br />

<strong>Profibus</strong><br />

TSXPBSCA••<br />

(••100=100m; 400=400m)<br />

Elaborado por: Flavio Mesquita Carneiro Revisão: 1<br />

Data: 10/12/08<br />

VW3A3307 + <strong>ATV71</strong><br />

490NAD91103


B) CONFIGURAÇÃO DA REDE PROFIBUS ATRAVÉS DO SYCON:<br />

INICIALMENTE, DEFINIMOS O CARTÃO TSXPBY100 COMO MESTRE DE REDE PROFIBUS E ADICIONAMOS O ESCRAVO PROFIBUS<br />

<strong>ATV71</strong> COMO ENDEREÇO 2:<br />

FIGURA 1: CONFIGURAÇÃO REDE PROFIBUS PARA MODICON PREMIUM – SYCON.<br />

PARA ADICIONAR O ESCRAVO <strong>ATV71</strong> É NECESSÁRIO IMPORTAR O .GSD DO DISPOSITIVO. BASTA CLICAR EM FILE E SELECIONAR<br />

COPY EDS, LOGO EM SEGUIDA SELECIONE O ARQUIVO NO NA PASTA ADEQUADA<br />

FIGURA 2: IMPORTANDO O EDS PARA O SYCON.<br />

2


DEPOIS DE IMPORTAR O GSD, NO MENU, SELECIONAR INSERT, NODE, CLIQUE ABAIXO DO MASTER INSERINDO UM NOVO NÓ. UMA<br />

NOVA TELA SERÁ ABERTA E NESTA TELA DEVE-SE CLICAR DUAS VEZES NO DISPOSITIVO ADEQUADO (GSD DO <strong>ATV71</strong>).<br />

FIGURA 3: INSERINDO NOVO NÓ NA CONFIGURAÇÃO DO SYCON<br />

A CONFIGURAÇÃO DO SLAVE VEM PRÉ-DEFINIDA<br />

FIGURA 4: MAPA DE VARIÁVEIS – SYCON.<br />

3


POSTERIORMENTE, AJUSTAMOS O BAUDRATE EM SETTINGS, BUS PARAMETERS, PARA1500KBIT/S.<br />

FIGURA 5: AJUSTE DE BAUDRATE.<br />

C) IMPORTANDO E DEFININDO ENDEREÇOS NO UNITY:<br />

EM SEGUIDA, AO SALVAR O PROJETO DO SYCON, IMPORTAMOS ESTE PROJETO NO UNITY QUE, TRAZ O MAPA DE VARIÁVEIS E<br />

DETERMINAMOS A QUANTIDADE DE REGISTROS NECESSÁRIOS PARA COMUNICAÇÃO E OS ENDEREÇOS NO CLP.<br />

FIGURA 6: MAPA CONFIGURAÇÃO DE VARIÁVEIS – UNITY.<br />

OS ENDEREÇOS RESERVADOS NO MAPA DE VARIAVEIS DO UNITY SÃO ASSOCIADOS ÀS FUNÇÕES DESEJADAS (ETA,CMD, ETC) NO<br />

MENU DE CONFIGURAÇÃO DO DRIVE.<br />

4


D) PARAMETRIZAÇÃO DO <strong>ATV71</strong>:<br />

NA PLACA PROFIBUS VW3A3307 É NECESSÁRIO CONFIGURAR O ENDEREÇO DO BUS ATRAVÉS DE SWITCHES, LOCALIZADO NA<br />

PROPRIA PLACA. ABAIXO, PROCEDIMENTO DE CONFIGURAÇÃO EXTRAIDO DO MANUAL DA PLACA.<br />

FIGURA 7: TABELA DE CONFIGURAÇÃO DO SWITCH<br />

5


MENU (1.6) COMMAND (COMANDO):<br />

REF1 CHANNEL (FR1) – MUDAR PARA COM. CARD<br />

PROFILE (CHCF) – MUDAR PARA NOT SEP.<br />

MENU (1.9) COM (COMUNICAÇÃO):<br />

COM. SCANNER INPUT (ICS)<br />

SCAN. IN1 ADDRESS (NMA1) – MUDAR PARA 3201 (ETA – STATUS WORD);<br />

SCAN. IN2 ADDRESS (NMA2) – MUDAR PARA 8604 (RFRD – OUTPUT SPEED);<br />

SCAN. IN3 ADDRESS (NMA3) – MUDAR PARA 3204 (LCR – MOTOR CURRENT).<br />

OS DEMAIS (DE IN4 ATÉ IN8) NÃO FORAM UTILIZADOS.<br />

COM. SCANNER OUTPUT (OCS)<br />

SCAN. OUT1 ADDRESS (NCA1) – MUDAR PARA 8601 (CMD – CONTROL WORD );<br />

SCAN. OUT2 ADDRESS (NCA2) – MUDAR PARA 8602 (LFRD – SPEED REFERENCE);<br />

SCAN. OUT3 ADDRESS (NCA3) – MUDAR PARA 9001 (ACC – ACELERATION);<br />

SCAN. OUT4 ADDRESS (NCA4) – MUDAR PARA 9002 (DEC – DECELERATION).<br />

OS DEMAIS (DE OUT5 ATÉ OUT8) NÃO FORAM UTILIZADOS<br />

ABAIXO, MAIS INFORMAÇÕES EXTRAIDAS DO MANUAL SOBRE A UTILIZAÇÃO DAS PDZ’S<br />

FIGURA 8: TABELA DE CONFIGURAÇÃO DO PDZ<br />

6


DEFINIÇÃO DOS BITS – WORD DE CONTROLE (CMD).<br />

A TABELA ABAIXO MOSTRA A DEFINIÇÃO DOS BITS DA PALAVRA DE CONTROLE (CMD W8601).<br />

FIGURA 9: DEFINIÇÃO DOS BITS DA WORD DE CONTROLE.<br />

7


DEFINIÇÃO DOS BITS – WORD DE STATUS (ETA W3201).<br />

A TABELA ABAIXO MOSTRA A DEFINIÇÃO DOS BITS DA PALAVRA DE STATUS (ETA W3201).<br />

FIGURA 10: DEFINIÇÃO DOS BITS DA WORD DE STATUS.<br />