12.07.2015 Views

AUTOSTART 705 (AS705S series) - Murphy

AUTOSTART 705 (AS705S series) - Murphy

AUTOSTART 705 (AS705S series) - Murphy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>AUTOSTART</strong> <strong>705</strong> (AS<strong>705</strong>S <strong>series</strong>)The Generator Controls Division ofPROGRAMMABLE GENERATOR CONTROLLERThe Autostart <strong>705</strong> provides the control features for theautomatic or manual starting, load transfer and shutdown ofa standby diesel generator or pump. The AS<strong>705</strong> is a microprocessorbased controller, giving full programmability oftimers, trip levels and control options, with front facia LEDsfor the indication of generator status and faults.Key features• Automatic or manual operation, selected by rotary switch(key-switch available as an option).• 17 LED status and fault indicators, including 5 LEDsfor custom programming and labelling• RS232 communications link for engine monitoring,control and Autostart programming from local PC• Comprehensive fault protection and alarm system:–low oil pressure, high engine temperature, overspeed,underspeed, charge fail, emergency stop, start fail, highand low battery voltage, 3 programmable fault inputs.• 6 programmable outputs, allowing remote signallingand control of over 30 different functions.• Pin compatibility with Autostart 710 and Keystart 9700ranges, allowing standardisation of panel wiring.• 96 x 96mm DIN standard, front panel mounted caseOperationAutostart’s operating mode is selected by use of its3 position front facia switch:–Off/reset. Disables the engine and resets alatched fault condition.Automatic start-up, load transfer and return tostandby in response to a mains fail or remotestart condition, with full fault protection.Manual start and stop of the generator, eitherimmediately on selecting manual mode or byuse of remote push button switches.Green and amber LEDs around the switch indicate theselection of Auto and Manual modes. On keyswitchversions, the key is common to all units and may beremoved in the Off and Auto positions only.Control OutputsThe following are provided:-• Single pole, switched +ve relay outputs for the controlof engine fuel and starter motor circuits.• Switched +ve outputs for signalling auto and manualmodes, plus a –ve DC output for Off/reset.• 6 function programmable outputs (see overleaf).Fault Protection and Alarm SystemIn Auto or Manual modes, Autostart will shut down and latchout the generator on detection of low oil pressure, highengine temperature, overspeed, start fail or emergencystop faults. The Autostart may also be set up to shut downthe generator on low generator frequency or speed.3 additional inputs may be used with remote fault switches(giving a ‘shutdown’ or ‘warning’ response), or as controlinputs with remote contacts or panel switches (see overleaf).Non-latching, 'warning only' alarms are fitted for high andlow battery volts, charge fail and mag. pickup fail conditions.Product SpecificationPower supply:Operating voltage: steady state rangecrank brown-outCurrent consumptionInputs:DC inputs (inputs 1 - 5, remote start)positive input voltage rangenegative input voltage rangeGenerator AC input:-operating voltage rangefrequency measurement rangeMagnetic pickup:-operating voltage rangefrequency measurement rangeOutputs:Start and fuel relaysProgrammable outputs 1 – 3Programmable output 4Programmable output 5(default setting: Common Alarm)Programmable output 6(default setting: Gen. contactor)Auto & Manual outputsOff/reset outputPhysical:Overall dimensions (W x H x D)Panel cut-out sizeWeightOperating ambient temperatureCase sealingRM011101Issue 6, revised 06/99Catalogue section 75(MS5258)5 – 40 V DC continuousto 0V for

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!