Gradientul <strong>de</strong> temperatura<br />
I<strong>de</strong>al Pardoseala radianta aeroterme radiatoare pe per.ext. Radiaroare pe perete int.<br />
08.06.2010 Roth Werke GmbH 2
Izolatie termica <strong>si</strong> fonica<br />
08.06.2010 Roth Werke GmbH 3
Componentele <strong>si</strong>stemului<br />
Placa/ rola izolatoare 35-3 PS-TK 5,0<br />
08.06.2010 Roth Werke GmbH 4
Componentele <strong>si</strong>stemului<br />
Placa izolatie 55-2 PS-TK 5,0<br />
08.06.2010 Roth Werke GmbH 5
Componentele <strong>si</strong>stemului<br />
Teava DUOPEX S5<br />
•Temperatura <strong>de</strong> lucru admi<strong>si</strong>bila 95°C<br />
(pentru durata scurta 110°C) la o pre<strong>si</strong>une<br />
<strong>de</strong> 6 bar.<br />
• Stabilitate a formei <strong>de</strong> lunga durata.<br />
• Rezistenta mecanica mare.<br />
• Flexibilitate mare la montaj chiar in<br />
conditii <strong>de</strong> temperatui exterioare reduse.<br />
• Etansa la difuziunea oxigenului <strong>prin</strong><br />
peretele tevii. (Conf.DIN 4726).<br />
08.06.2010 Roth Werke GmbH 6
Pozare in forma <strong>de</strong> meandre<br />
08.06.2010 Roth Werke GmbH 7
Pozare in forma <strong>de</strong> melc<br />
08.06.2010 Roth Werke GmbH 8
Montajul placilor izolatoare<br />
08.06.2010 Roth Werke GmbH 9
Montajul placilor izolatoare<br />
Margini <strong>de</strong> acoperire autoa<strong>de</strong>zive<br />
Resturi minime<br />
Folia <strong>de</strong> acoperire este aplicata din fabrica<br />
pe izolatie<br />
08.06.2010 Roth Werke GmbH 10
Montajul tevii<br />
Montaj <strong>si</strong>mplu <strong>si</strong> rapid cu ajutorul <strong>si</strong>stemului<br />
„TACKER“ patentat <strong>de</strong> ROTH<br />
Fixarea este po<strong>si</strong>bila in orice punct al placii<br />
permitind astfel orice distanta <strong>de</strong> pozare intre<br />
tevi.<br />
08.06.2010 Roth Werke GmbH 11
Rosturile <strong>de</strong> dilatare<br />
08.06.2010 Roth Werke GmbH 12
Sectiune <strong>prin</strong> elementele <strong>si</strong>stemului<br />
Deasupra unor incaperi incalzite<br />
08.06.2010 Roth Werke GmbH 13
Sectiune <strong>prin</strong> elementele <strong>si</strong>stemului<br />
Deasupra unor incaperi neincalzite<br />
08.06.2010 Roth Werke GmbH 14
Sectiune <strong>prin</strong> elementele <strong>si</strong>stemului<br />
Deasupra unor spatii in aer liber sau direct pe sol<br />
08.06.2010 Roth Werke GmbH 15
Echilibrarea <strong>si</strong>stemului<br />
Distribuitoare cu <strong>de</strong>ditmetre<br />
08.06.2010 Roth Werke GmbH 16
Tehnica <strong>de</strong> reglaj<br />
Statia <strong>de</strong> reglaj RKRV<br />
08.06.2010 Roth Werke GmbH 17
Termostate <strong>si</strong> telecomenzi<br />
08.06.2010 Roth Werke GmbH 18
Incalzirea <strong>prin</strong> perete<br />
08.06.2010 Roth Werke GmbH 19
Incalzirea <strong>prin</strong> perete<br />
08.06.2010 Roth Werke GmbH 20
Incalzirea <strong>prin</strong> perete<br />
08.06.2010 Roth Werke GmbH 21
Incalzirea <strong>prin</strong> perete<br />
08.06.2010 Roth Werke GmbH 22
Incalzirea <strong>prin</strong> perete<br />
08.06.2010 Roth Werke GmbH 23
Sistemul cu izolatie tip fagure<br />
08.06.2010 Roth Werke GmbH 24
Roth ClimaComfort System<br />
08.06.2010 Roth Werke GmbH 25
Incalzire <strong>si</strong> racire<br />
08.06.2010 Roth Werke GmbH 26
Roth - Pompe <strong>de</strong> <strong>caldura</strong><br />
08.06.2010 Roth Werke GmbH 27
Evolutia pietei pompelor <strong>de</strong> <strong>caldura</strong> in Germania<br />
1996 - 2003<br />
Absatz (Stck.)<br />
10.000<br />
9.000<br />
8.000<br />
7.000<br />
6.000<br />
5.000<br />
4.000<br />
3.000<br />
2.000<br />
<strong>1.</strong>000<br />
0<br />
2.310<br />
518<br />
273<br />
<strong>1.</strong>519<br />
3.580<br />
691<br />
582<br />
2.307<br />
647<br />
564<br />
3.156<br />
774<br />
537<br />
3.408<br />
993<br />
594<br />
4.367 4.719 5.736<br />
4.149<br />
<strong>1.</strong>562<br />
<strong>1.</strong>238<br />
5.415<br />
<strong>1.</strong>524<br />
<strong>1.</strong>439<br />
5.363<br />
2.396<br />
<strong>1.</strong>152<br />
1996 1997 1998 1999 2000 2001 2002 2003<br />
Er<strong>de</strong>/Sole Wasser Luft Jahre<br />
8.215 8.326<br />
9.745<br />
6.197<br />
Quelle: BWP e.V (aktuali<strong>si</strong>ert März 2004)<br />
08.06.2010 Roth Werke GmbH 28
Principalele avantaje ale pompelor <strong>de</strong> <strong>caldura</strong>´:<br />
• Reducerea emi<strong>si</strong>ei <strong>de</strong> CO 2<br />
• In<strong>de</strong>pen<strong>de</strong>nta fata <strong>de</strong> <strong>surse</strong>le <strong>de</strong> energie conventionala<br />
• Costuri reduse in utilizare datorita tarifelor diferentiate pentru energia<br />
electrica noaptea fata <strong>de</strong> ziua care compenseaza costul mare al<br />
amortizarii.<br />
• Compatibilitate excelenta cu casele izolate ( pentru un consum<br />
energetic redus<br />
• Economia <strong>de</strong> spatiu<br />
• Po<strong>si</strong>bilitatea <strong>de</strong> racire pe timpul verii.<br />
08.06.2010 Roth Werke GmbH 29
De ce prezinta Roth Pompa <strong>de</strong> <strong>caldura</strong> pe piata ?<br />
• Roth este unul dintre conducatorii <strong>de</strong> piata in domeniul instalatiillor <strong>de</strong><br />
<strong>incalzire</strong> <strong>prin</strong> <strong>pardoseala</strong> <strong>si</strong> <strong>pereti</strong>.<br />
• Pompa <strong>de</strong> <strong>caldura</strong> este cea mai potrivita sursa <strong>de</strong> <strong>caldura</strong> pentru acest <strong>si</strong>stem<br />
<strong>de</strong> distributie al caldurii. Roth ofera astfel un <strong>si</strong>stem complet ; <strong>si</strong>stemul<br />
<strong>de</strong> <strong>incalzire</strong> <strong>si</strong> racire <strong>prin</strong> <strong>pardoseala</strong> <strong>si</strong> <strong>pereti</strong> castiga teren pe piata.<br />
• Centrala energetica Roth cu pompa <strong>de</strong> <strong>caldura</strong> in combinatie cu racire activa<br />
sau pa<strong>si</strong>va este un concept <strong>de</strong> viitor cu perspectiva.<br />
08.06.2010 Roth Werke GmbH 30
• Pompele <strong>de</strong> <strong>caldura</strong> Roth reprezinta o sursa <strong>de</strong> energie in varianta<br />
constructiva completa, pregatita doar pentru racordare. Astfel<br />
montajul este <strong>de</strong>osedit <strong>de</strong> <strong>si</strong>mplu.<br />
• Efortul <strong>de</strong> proiectare este minim , toate componentele <strong>si</strong>stemului fiind<br />
dimen<strong>si</strong>onate in corelatie <strong>de</strong> producator.<br />
08.06.2010 Roth Werke GmbH 31
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Surse <strong>de</strong> <strong>caldura</strong> / moduri <strong>de</strong> functionare<br />
Serpentine colectoare orizontale<br />
Putere castigata<br />
15 ... 25 W/m²<br />
Distanta <strong>de</strong> montaj<br />
ca. 0,60...0,80 m<br />
Adancimea <strong>de</strong> montaj<br />
ca. 1,0...1,2 m<br />
08.06.2010 ROTH F&E- Energiesysteme – Hoe<br />
Roth Werke GmbH Folie17<br />
32
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Surse <strong>de</strong> <strong>caldura</strong> / moduri <strong>de</strong> functionare<br />
Son<strong>de</strong> verticale in pamant<br />
Incalzire <strong>si</strong> racire<br />
Putere recuperata: 30...80 W/m<br />
08.06.2010 ROTH F&E- Energiesysteme - Hoe<br />
Roth Werke GmbH Folie18<br />
33
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Surse <strong>de</strong> <strong>caldura</strong> / moduri <strong>de</strong> functionare<br />
Forme constructive <strong>de</strong> son<strong>de</strong><br />
• Sistem teava in teava<br />
• Sistem dublu U<br />
08.06.2010 ROTH F&E- Energiesysteme - Hoe<br />
Roth Werke GmbH Folie19<br />
34
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Surse <strong>de</strong> <strong>caldura</strong> / moduri <strong>de</strong> functionare<br />
Varful son<strong>de</strong>i tip U dubla<br />
PE-HD 25 x 2,30 mm mufa sudata<br />
08.06.2010 Roth Werke GmbH 35<br />
ROTH F&E- Energiesysteme - Hoe Folie 20
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Tehnica forajului<br />
08.06.2010 Roth Werke GmbH 36<br />
ROTH F&E- Energiesysteme - Hoe Folie 21
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Tehnica forajului<br />
08.06.2010 Roth Werke GmbH 37<br />
ROTH F&E- Energiesysteme - Hoe Folie 22
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Foraj cu burghiu elicoidal pentru sonda<br />
<strong>de</strong> pana la 50 m in teren usor<br />
08.06.2010 Roth Werke GmbH 38<br />
ROTH F&E- Energiesysteme - Hoe Folie 23
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Introducerea son<strong>de</strong>i in interiorul forajului<br />
Dupa introducerea son<strong>de</strong>i iu interiorul<br />
burghiului elicoidal prevazut cu un gol in<br />
interior, acesta se scote <strong>prin</strong> invartire spre<br />
stanga, pe segmente<strong>de</strong> 1 m.<br />
08.06.2010 Roth Werke GmbH 39<br />
ROTH F&E- Energiesysteme - Hoe Folie 24
Technica pompei <strong>de</strong> <strong>caldura</strong><br />
Centrala energetica Roth<br />
Constructie<br />
• Constructie modulara:<br />
•Sursa <strong>de</strong> rece <strong>si</strong> <strong>de</strong> cald<br />
•Electrica<br />
• Boilerul <strong>si</strong> racordurile<br />
08.06.2010 Roth Werke GmbH 40
Sa folo<strong>si</strong>m soarele asa cum trebuie!<br />
08.06.2010 Roth Werke GmbH 41
Despre utilizarea energiei solare<br />
• Instalatiile solare pot incalzi anual peste 60 % din<br />
necesarul <strong>de</strong> apa calda pentru baie <strong>si</strong> bucatarie al unei<br />
case <strong>de</strong> locuit<br />
• Din luna mai pana in septembrie este po<strong>si</strong>bila acoperirea<br />
integrala a necesarului <strong>de</strong> apa calda menajera cu instalatia<br />
solara.<br />
08.06.2010 Roth Werke GmbH 42
Despre utilizarea energiei solare<br />
08.06.2010 Roth Werke GmbH 43
Produsele Roth pentru utilizarea energiei solare<br />
08.06.2010 Roth Werke GmbH 44
Colectorul Roth F 1<br />
F1 – Unul dintre cele mai puternice la categoria lui<br />
08.06.2010 Roth Werke GmbH 45
Colectorul Roth F 1<br />
Flexibilitate la amplasare<br />
• Montaj pe acoperis<br />
• Integrat in acoperis<br />
•Montaj liber<br />
08.06.2010 Roth Werke GmbH 46
Colectorul Roth F 1<br />
Date tehnice<br />
Lungime:<br />
2151 mm<br />
Latime:<br />
1215 mm<br />
Gro<strong>si</strong>me:<br />
110 mm<br />
Suprafata totala: 2,61 m²<br />
08.06.2010 Roth Werke GmbH 47
Colectorul Roth F 1<br />
Date tehnice<br />
Suprafata absorbanta: 2,33 m²<br />
Masa:<br />
48 kg<br />
10 ani garantie<br />
08.06.2010 Roth Werke GmbH 48
Colectorul Roth F 1<br />
Date tehnice:<br />
Randamentul colectorului: η 0 = 81,80 %<br />
Rama colectoruilui:<br />
Aluminiu eloxat cu izolatie <strong>de</strong> 60 mm<br />
pe rama <strong>si</strong> baza panoului<br />
08.06.2010 Roth Werke GmbH 49
Colectorul Roth F 1<br />
Date tehnice constructive<br />
Sticla <strong>de</strong> acoperire:<br />
Sticla securizata <strong>de</strong> 4mm<br />
Coeficient <strong>de</strong> transmi<strong>si</strong>e t = 91%<br />
Suprafata absorbanta:<br />
Tabla <strong>si</strong> tuburi din cupru<br />
08.06.2010 Roth Werke GmbH 50
Colectorul Roth F 1<br />
Date tehnice constructive<br />
Pre<strong>si</strong>unea <strong>de</strong> lucru (max.):<br />
10 bar<br />
Temperatura admisa: 227°C (conf. DIN 4757-3)<br />
Teaca sensorului :<br />
∅ = 6 mm<br />
Racorduri colector:<br />
½“filet exterior<br />
Energie anuala:<br />
peste 525 kWh/m²an<br />
08.06.2010 Roth Werke GmbH 51
Pachete <strong>de</strong> instalatii solare Roth F1<br />
08.06.2010 Roth Werke GmbH 52
Pachete <strong>de</strong> instalatii solare Roth F1<br />
Exemplu:<br />
Numar <strong>de</strong> persoane: 5-6<br />
Numar <strong>de</strong> colectoare: 4<br />
Suprafata colectoarelor: 10,4 m²<br />
Volumul boilerului:<br />
700 Liter<br />
Numar <strong>de</strong> persoane: 7-10<br />
Numar <strong>de</strong> colectoare: 6<br />
Suprafata colectoarelor: 15,6 m²<br />
Volumul boilerului:<br />
1000 Liter<br />
08.06.2010 Roth Werke GmbH 53
Captatoare solare cu tuburi vidate Roth R1<br />
Puteri exceptionale<br />
08.06.2010 Roth Werke GmbH 54
Captatoare solare cu tuburi vidate Roth R1<br />
Se pot inseria pana la sase module Roth R1<br />
08.06.2010 Roth Werke GmbH 55
Captatoare solare cu tuburi vidate Roth R1<br />
Date tehnice constructive<br />
Lungime:<br />
1650 mm<br />
Latime:<br />
780 mm<br />
Gro<strong>si</strong>me:<br />
137 mm<br />
Prezentare:<br />
7 Tuburi/Modul<br />
08.06.2010 Roth Werke GmbH 56
Captatoare solare cu tuburi vidate Roth R1<br />
Temperatura admisa: 265°C (nach DIN 4757 – 3)<br />
08.06.2010 Roth Werke GmbH 57
Boilerul pentru <strong>si</strong>stemul solar <strong>si</strong> accesoriile<br />
Date constructive<br />
08.06.2010 Roth Werke GmbH 58
Tehnica <strong>de</strong> reglaj a instalatiilor solare<br />
08.06.2010 Roth Werke GmbH 59
<strong>Sisteme</strong> <strong>de</strong> captare a energiei solare<br />
Din responsabilitate fata <strong>de</strong> generatiile care vor urma<br />
08.06.2010 Roth Werke GmbH 60