Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Centrala in condensatie pe gaz<br />

cu sistem de preparare ACM integrat<br />

Descriere<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />

(21/18, 26/23, 32/28)<br />

Centrala in condensatie pe gaz<br />

• Cu tehnica de condensatie<br />

• Schimbator de caldura din aliaj de aluminiu rezistent la<br />

coroziune cu sistem de circulatie fortata cu spirala de<br />

cupru.<br />

• Prepararea de ACM prin a doua spirala de cupru<br />

integrata in centrala.<br />

• Contine:<br />

- pompa pentru circuitul de incalzire<br />

- manometru electronic<br />

- aerisitor manual<br />

- limitator de temperatura gaze arse<br />

- fluxostat pe circuitul de ACM<br />

• Arzator cu preamestec din inox<br />

- Modulant cu controlarea raportului aer/gaz<br />

- Aprindere automata<br />

- Supraveghere flacara (ionizare)<br />

• Centrala pe gaz murala, montata in carcasa din tabla<br />

de otel vopsita in alb<br />

Panou de comanda al cazanului N4.4<br />

• Automat de ardere cu sistem de supraveghere BIC<br />

300<br />

• Comanda modulanta a arzatorului<br />

• Intrerupator electronic „I/O“<br />

• Afisare functionare si defectiuni<br />

• Comanda preparare apa calda cu fluxostat.<br />

• Cu posibilitatea de conectare a max. 1 statie de<br />

camera sau 1 telecomanda cu senzor de camera.<br />

Varinte configurabile<br />

• Robineti de gaz<br />

• Cu cadru de montaj<br />

• Cu cadru de montaj si vas de expansiune integrat<br />

• Seturi de conectare<br />

Livrare<br />

• Centrala murala montata in carcasa<br />

• Sistem de prindere si sifon de condens<br />

• Instructiuni de montaj<br />

• Instructiuni de utilizare<br />

Set regulator de incalzire RS-OT<br />

• Pentru 1 circuit de incalzire fara amestec<br />

• Reglarea temperaturii apei din cazan functie de<br />

temperatura exterioara<br />

• RS-OT cu posibilitatea de activare a senzorului<br />

ambiental de temperatura pentru camera, amplasare<br />

in camera centralei sau camera de zi<br />

• Senzor de exterior AF 120<br />

• Senzor de boiler TF 25 / 12K<br />

Nu poate fi montat in panoul centralei!<br />

<strong>TopGas</strong> ®<br />

Tip<br />

Putere incalzire<br />

kW<br />

<strong>combi</strong> (21/18) 5,9 - 18,6<br />

<strong>combi</strong> (26/23) 7,6 - 23,4<br />

<strong>combi</strong> (32/28) 7,8 - 27,1<br />

Certificarea cazanului<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28):<br />

CE-Product-ID-No.<br />

0063BQ3155<br />

Nota:<br />

<strong>TopGas</strong> ® <strong>combi</strong> poate fi utilizat numai daca apa<br />

potabila are o duritate mai mica de 13 germane<br />

(d°H).<br />

Subject to modification, 1.4.20<strong>08</strong><br />

Centrale si cazane murale<br />

19


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Coduri articole / Preturi<br />

Centrale murale pe gaz in condensatie<br />

<strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Coduri articole<br />

Schimbator de caldura din aliaj de aluminiu rezistent la<br />

coroziune cu sistem de circulatie fortata cu spirala de<br />

cupru. Prepararea api calde se realizeaza printr-o a doua<br />

integrata in centrala.<br />

Cu arzator modulant cu preamestec din inox, inclusiv<br />

sistemul de comanda de baza N4.4 al centralei, montat in<br />

carcasa.<br />

<strong>TopGas</strong> ® <strong>combi</strong><br />

Putere incalzire<br />

Tip kW 1<br />

<strong>combi</strong> (21/18) 5,9 - 18,6<br />

<strong>combi</strong> (26/23) 7,6 - 23,4<br />

<strong>combi</strong> (32/28) 7,8 - 27,1<br />

1<br />

kW = Interval de modulare la 40/30 °C<br />

70<strong>03</strong> 949<br />

70<strong>03</strong> 652<br />

70<strong>03</strong> 653<br />

1.751<br />

1.790<br />

1.854<br />

Nota:<br />

<strong>TopGas</strong> ® <strong>combi</strong> poate fi utilizat numai daca apa<br />

potabila are o duritate mai mica de 13 germane<br />

(d°H).<br />

Accesorii<br />

Set de modificare pentru gaz lichefiat<br />

<strong>TopGas</strong> ® <strong>combi</strong> (21/18) 2025 781<br />

<strong>TopGas</strong> ® <strong>combi</strong> (26/23, 32/28) 2025 782<br />

12<br />

12<br />

Piesa de racordare pentru gaze arse E80<br />

pentru separarea conductei de evacuare gaze arse de<br />

conducta de admisie aer de ardere. 2029 057<br />

46<br />

Aerisitor automat 3/8" 240 191<br />

13<br />

Consola pentru premontare<br />

Pentru preinstalarea racordurilor de gaz, tur si retur, apa<br />

rece si apa calda.<br />

Compatibila cu toate tipurile de cadre de montaj sau<br />

fara cadru de montaj!<br />

2025 779<br />

251<br />

Set de conexiune 3<br />

Pentru Hoval <strong>TopGas</strong> ® classic fara boiler, fara/ cu cadru<br />

de montaj.<br />

Compus din: conector gaz, conector tur, conector retur<br />

cu supapa diferentiala de presiune, supapa de siguranta<br />

3 bar, robinet de umplere/golire, racord conectare vas de<br />

expansiune, 2 robineti cu bila pe incalzire.<br />

Robineti cu filet interior tur/retur R 3/4““ 2001 257<br />

186<br />

Set extensie pentru circuitul sanitar<br />

2 piese<br />

Absolut necesar pentru montarea cu setul de<br />

conexiune 3 pentru <strong>TopGas</strong> ® <strong>combi</strong>.<br />

6016 874<br />

39<br />

20<br />

Centrale si cazane murale<br />

Subject to modification, 1.4.20<strong>08</strong>


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Coduri articole / Preturi<br />

Accesorii <strong>TopGas</strong> ® <strong>combi</strong><br />

Coduri articole<br />

Set de conectare jos<br />

(nu este posibila <strong>combi</strong>narea cu setul de conexiune 3)<br />

pentru Hoval <strong>TopGas</strong> ® <strong>combi</strong>, cu / fara cadru de montaj.<br />

Compus din: robinet de apa rece, supapa de siguranta<br />

pentru instalatia sanitara 8 bar, supapa de siguranta pentru<br />

incalzire 3 bar, robinet de umplere / golire, conectori<br />

cu inel de strangere D22 pentru tur si retur. 2022 914<br />

172<br />

Cadru de montaj MR50 fara vas de expansiune<br />

pentru marirea distantei fata de perete, pentru usurarea<br />

montajului (de ex.. piesa pentru gaze arse direct pe<br />

perete). Nu este strict necesar.<br />

<strong>TopGas</strong> ® <strong>combi</strong> (21/18) 2029 696<br />

<strong>TopGas</strong> ® <strong>combi</strong> (26/23) 2029 701<br />

43<br />

51<br />

<strong>TopGas</strong> ® <strong>combi</strong> (32/28) 2029 702<br />

55<br />

Cadru de montaj MR110 cu vas de expansiune si<br />

furtun flexibil pentru racordare la setul de conexiune<br />

3. Vasul de expansiune se conecteaza la setul de<br />

conectare jos, la montare!<br />

Cadru pentru prinderea centralei Hoval <strong>TopGas</strong> ®<br />

<strong>combi</strong> cu vas de expansiune integrat<br />

volum 12 l / pre-incarcare 0,75 bar<br />

<strong>TopGas</strong> ® <strong>combi</strong> (21/18) 6016 863<br />

<strong>TopGas</strong> ® <strong>combi</strong> (26/23) 6016 864<br />

<strong>TopGas</strong> ® <strong>combi</strong> (32/28) 6016 865<br />

238<br />

238<br />

238<br />

Masca pentru Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />

pentru acoperirea racordurilor de gaz, tur, retur la Top-<br />

Gas ® <strong>combi</strong> (21/18, 26/23, 32/28), in <strong>combi</strong>natie cu setul<br />

de conexiune 3<br />

Este posibila <strong>combi</strong>narea fara/ cu cadrul de montaj<br />

MR50/MR110. 3, precum si cu setul de conectare jos.<br />

2029 787<br />

39<br />

Set regulator de incalzire RS-OT<br />

(Nu este pt. sistem de functionare cu amestec!)<br />

Pentru 1 circuit fara amestec<br />

Reglarea temperaturii turului functie de temperatura<br />

exterioara cu senzor de exterior AF 120, water senzor de<br />

boiler TF 25 / 12K si cu posibilitatea activarii senzorului<br />

de interior. Poate fi utilizat si pentru reglarea temperaturii<br />

camerei fara senzor de exterior.<br />

Nu poate fi montat in panoul de comanda al centralei!<br />

6015 199<br />

238<br />

Subject to modification, 1.4.20<strong>08</strong><br />

Centrale si cazane murale<br />

21


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Coduri articole / Preturi<br />

Accesorii <strong>TopGas</strong> ® <strong>combi</strong><br />

Limitator de temperatura pentru circuitul de incalzire<br />

- pentru incalzirea in pardoseala (1 limitator pentru<br />

fiecare circuit)<br />

15-95 °C, differential gap 6K, tub capilar max. 700 mm,<br />

setare (vizibil din exterior) sub capacul carcasei.<br />

Coduri articole<br />

Termostat de contact RAK-TW1000.S<br />

Termostat cu colier de prindere, fara cablu si stecker 242 902<br />

68<br />

Robinet de gaz de trecere DN ½“<br />

(cu declansare termica) 2012 075<br />

43<br />

Robinet de gaz, varianta de colt DN ½“<br />

(cu declansare termica) 2012 076<br />

Conector cu inel de strangere nr. 1 (½“ AG x 15)<br />

pentru robinetul de gaz, apa calda sau apa rece<br />

cand nu se utilizeaza seturile de conexiune 3, consola<br />

pentru premontare sau setul de conectare jos. 2001 824<br />

51<br />

6<br />

Conector cu inel de strangere nr. 1 (¾" AG x 22)<br />

pentru tur si retur<br />

cand nu se utilizeaza seturile de conexiune 3, consola<br />

pentru premontare sau setul de conectare jos. 2029 325<br />

9<br />

Separator de impuritati<br />

DC 20 - ¾“<br />

DC 25 - 1“<br />

2029 530<br />

2029 531<br />

1<strong>08</strong><br />

1<strong>08</strong><br />

Aerisitor rapid cu blocare<br />

accesoriu pentru separatorul de impuritati 2002 582<br />

36<br />

Service<br />

Punere in functiune<br />

Punerea in functiune prin departamentul de service<br />

al Hoval <strong>RO</strong> sau printr-o firma specializata autorizata,<br />

constituie o premisa pentru acordarea garantiei.<br />

Pentru punerea in functiune si alte sevicii va rugam sa<br />

va adresati catre Hoval <strong>RO</strong>.<br />

22<br />

Centrale si cazane murale<br />

Subject to modification, 1.4.20<strong>08</strong>


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Date tehnice<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />

Tip (21/18) (26/23) (32/28)<br />

• Putere nominala 80/60 °C la gaze naturale 1 kW 5,4 - 17,8 6,9 - 22,8 7,1 - 26,3<br />

• Putere nominala 40/30 °C la gaze naturale 1 kW 5,9 - 18,6 7,6 - 23,4 7,8 - 27,1<br />

• Putere nominala 80/60 °C la propan 3 kW 5,7 - 17,8 7,3 - 22,8 7,3 - 26,3<br />

• Putere nominala 40/30 °C la propan 3 kW 6,3 - 18,6 8,0 - 23,4 8,0 - 27,4<br />

• Sarcina nominala la gaze naturale 1 kW 5,6 - 18,7 7,1 - 23,7 7,2 - 27,3<br />

• Sarcina nominala instalatie sanitara la gaze naturale 1 kW 5,6 - 22,1 7,1 - 28,0 7,5 - 32,7<br />

• Sarcina nominala la propan 3 kW 5,9 - 18,7 7,5 - 23,7 7,5 - 27,3<br />

• Presiune de lucru max./min. bar 3,0 / 1,0 3,0 / 1,0 3,0 / 1,0<br />

• Temperatura maxima de lucru °C 85 85 85<br />

• Volumul de apa al cazanului l 1,4 1,7 2,0<br />

• Debit minim circulatie apa in cazan l/h 180 180 180<br />

• Greutate cazan (fara apa) kg 34 38 42<br />

• Randamentul normat (DIN 4702, partea 8) 40/30 °C % 1<strong>08</strong> / 97,3 1<strong>08</strong> / 97,3 1<strong>08</strong> / 97,3<br />

(raportat la PCI / raportat la PCS) 75/60 °C % 1<strong>03</strong>,3 / 93,1 1<strong>03</strong>,3 / 93,1 1<strong>03</strong>,3 / 93,1<br />

• Pierderi de putere in stand-by la 70 °C Watt 60 80 95<br />

• Valoarea emisiilor standard<br />

Oxizi de azot NOx mg/kWh 35 60 66<br />

Monoxizi de carbon CO mg/kWh 65 65 65<br />

• Continut de CO 2<br />

in gazele arse putere max./min. % 9,0/8,8 9,0/8,8 9,0/8,8<br />

• Dimensiuni:<br />

Vezi subcapitolul Dimensiuni<br />

• Racorduri<br />

Tur / Retur D22 D22 D22<br />

Apa rece / Apa calda D15 D15 D15<br />

Gaz D15 D15 D15<br />

Gaze arse / aer de ardere (concentric) mm 80/125 80/125 80/125<br />

suplimentar pentru alimentarea directa cu aer de ardere mm 80 80 80<br />

• Presiune curgere gaze min./ max.<br />

gaze naturale E/LL mbar 18 - 50 18 - 50 18 - 50<br />

propan mbar 25 - 50 25 - 50 25 - 50<br />

• Consum de gaze (puterea gazului la 0 °C / 1013 mbar):<br />

Gaz natural E - (Wo = 15,0 kWh/m 3 ) H u<br />

= 9,97 kWh/m 3 m 3 /h 1,87 2,37 2,73<br />

Gaz natural LL- (Wo = 12,4 kWh/m 3 ) H u<br />

= 8,57 kWh/m 3 m 3 /h 2,18 2,77 3,19<br />

Propan 3 (H u<br />

= 25,9 kWh/m 3 ) m 3 /h 0,72 0,92 1,05<br />

• Tensiune de lucru V/Hz 230 / 50 230 / 50 230 / 50<br />

• Consum electric min./max. (inclusiv pompa) Watt 13 / 85 13 / 89 13 / 95<br />

• Tip protectie IPx2D 40 40 40<br />

• Nivel de zgomot dB(A) 56 56 57<br />

• Nivelul de presiune fonica<br />

dB(A) 45 45 46<br />

(depinde de conditiile de montare) 2<br />

• Cantitatea de condens (gaze naturale) la 40 / 30 °C l/h 1,8 2,2 2,6<br />

• Valoare pH a condensului ca. 4,2 ca. 4,2 ca. 4,2<br />

• Valori pentru calculul cosului de fum<br />

Tip clasa de temperatura pentru gaze arse T 120 T 120 T 120<br />

Debitul masic al gazelor arse kg/h 31,0 39,3 45,3<br />

Temperatura gazelor arse functionare la 80/60 °C °C 85 85 85<br />

Temperatura gazelor arse functionare la 40/30 °C °C 64 64 64<br />

Presiunea disponibila pentru alimentare aer / evacuare gaze arse Pa 75 75 75<br />

Depresiunea maxima pe conducta de evacuare Pa - 50 - 50 - 50<br />

1<br />

Date raportate la H u<br />

. Seria cazanelor este testata pentru EE/H. Cu setarile din fabrica a coeficientului Wobbe de 15,0 kWh/m3 este posibila functionarea la un coeficient Wobbe<br />

de la 12,0 pana la 15 , 7 kWh/m3 fara setari noi.<br />

2<br />

Vezi si indicatiile de proiectare<br />

3<br />

Cazanele <strong>TopGas</strong> ® <strong>combi</strong> pot fi utilizate si pentru amestecuri de Propan / Butan (gaz lichefiat).<br />

Subject to modification, 1.4.20<strong>08</strong><br />

Centrale si cazane murale<br />

23


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Date tehnice<br />

Inaltimea maxima de pompare<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18)<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong> (26/23)<br />

Inaltimea de pompare (mbar)<br />

600<br />

550<br />

500<br />

3<br />

450<br />

400<br />

350<br />

2<br />

300<br />

250<br />

200<br />

1<br />

150<br />

100<br />

50<br />

0<br />

0 250 500 750 1000 1250 1500 1750 2000<br />

Inaltimea de pompare (mbar)<br />

600<br />

550<br />

500<br />

3<br />

450<br />

400<br />

2<br />

350<br />

300<br />

250<br />

200<br />

1<br />

150<br />

100<br />

50<br />

0<br />

0 250 500 750 1000 1250 1500 1750 2000<br />

Debit (l/h)<br />

Debit (l/h)<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong> (32/28)<br />

Inaltimea de pompare (mbar)<br />

600<br />

550<br />

500<br />

450<br />

3<br />

400<br />

350<br />

2<br />

300<br />

250<br />

200<br />

1<br />

150<br />

100<br />

50<br />

0<br />

0 250 500 750 1000 1250 1500 1750 2000<br />

Debit (l/h)<br />

1 Treapta 1<br />

2 Treapta 2<br />

3 Treapta 3<br />

Putere încalzire apa cu <strong>TopGas</strong> ® <strong>combi</strong><br />

Pierderi de putere in<br />

Putere incalzire apa<br />

stand-by qB<br />

<strong>TopGas</strong> ® <strong>combi</strong> dm 3 /10 min 1 dm 3 /h 2 dm 3 /10 min 1 dm 3 /h 2 Debitul max. Numar 3 (70 °C)<br />

Tip 40 °C 40 °C 45 °C 45 °C dm 3 /10 min de locuinte Watt<br />

(21/18) 97 579 83 497 60 1 60<br />

(26/23) 126 759 1<strong>08</strong> 650 80 1 80<br />

(32/28) 145 869 124 745 95 1 95<br />

1<br />

Debit de apa calda (pe termen scurt ) 10 min. conform regurilor de verificare Procal<br />

Valorile pot fi obtinute doar prin controlul debitului si a temperaturii apei reci de intrare!<br />

2<br />

Debit de apa calda pe ora conform regurilor de verificare Procal.<br />

Valorile pot fi obtinute doar prin controlul debitului si a temperaturii apei reci de intrare!<br />

3<br />

Locuinta (3-4 camere cu 3-4 persoane,1 cada cu cca. 150 litri, 1 chiuveta, 1 lavoar)<br />

Nota:<br />

<strong>TopGas</strong> ® <strong>combi</strong> poate fi utilizat doar daca duritatea<br />

apei reci este sub<br />

13 d°H (grade germane).<br />

24<br />

Centrale si cazane murale<br />

Subject to modification, 1.4.20<strong>08</strong>


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Dimensiuni<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Dimensiuni minime<br />

(Valori in mm)<br />

• Lateral 50 mm<br />

• Distanta fata de tavan depinde<br />

de sistemul de evacuare<br />

a gazelor arse utilizate<br />

• In fata 500 mm<br />

(apa calda/ rece)<br />

(tur, retur, gaz)<br />

Conducta flexibila d 25<br />

<strong>TopGas</strong> ® <strong>combi</strong><br />

Tip a b1 b2 d e f g h i k l m<br />

(21/18) 590 460 0 50 75 185 170 65 247 – 30<br />

(21/18) cu cadrul de montaj (MR50) 590 574 50 100 125 235 220 115 297 834 80<br />

(21/18) cu cadrul de montaj cu vas de expansiune (MR110) 590 574 110 160 185 295 280 175 357 590 140<br />

(26/23) 650 520 0 50 75 185 170 65 247 – 30<br />

(26/23) cu cadrul de montaj (MR50) 650 634 50 100 125 235 220 115 297 894 80<br />

(26/23) cu cadrul de montaj cu vas de expansiune (MR110) 650 634 110 160 185 295 280 175 357 650 140<br />

(32/28) 710 580 0 50 75 185 170 65 247 – 30<br />

(32/28) cu cadrul de montaj (MR50) 710 694 50 100 125 235 220 115 297 954 80<br />

(32/28) cu cadrul de montaj cu vas de expansiune (MR110) 710 694 110 160 185 295 280 175 357 710 140<br />

1 Racord gaz D15<br />

(pentru conector Rp ½“ cu inel de strangere)<br />

2 Racord retur D22<br />

(pentru conector Rp ¾“ cu inel de strangere)<br />

3 Racord tur D22<br />

(pentru conector Rp ¾“ cu inel de strangere)<br />

4 Racord apa calda D15<br />

(pentru conector Rp ½“ cu inel de strangere)<br />

5 Racord apa rece D15<br />

(pentru conector Rp ½“ cu inel de strangere)<br />

6 Racord concentric pentru gaze arse si alimentare<br />

aer C80/125 incl. orificiu de masura<br />

6a Racord simplu pentru gaze arse E80 (optional)<br />

7 Alimentare cu aer din exterior D80<br />

8 Racord pentru evacuarea condensului<br />

Ø 32 mm (racord D25/21)<br />

9 Sifon<br />

10 Cadrul de montaj, latime 50 mm sau<br />

110 mm cu vas de expansiune<br />

opţional, vezi accesorii<br />

11a Loc pentru gaurire D10 fara cadrul de montaj<br />

11b Loc pentru gaurire D10 cu cadrul de montaj<br />

Subject to modification, 1.4.20<strong>08</strong><br />

Centrale si cazane murale<br />

25


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Proiectare<br />

Prescriptii si directive<br />

Trebuie respectate urmatoarele prescriptii si directive:<br />

- Informatiile tehnice si instructiunile de montare Hoval.<br />

- Prescriptiile hidraulice si normele tehnice ale firmei<br />

Hoval.<br />

- Prescriptiile ISCIR<br />

- Prescriptiile pompierilor<br />

- Directivele DVGW.<br />

- DIN EN 12828<br />

Cerinte tehnice de siguranta.<br />

- DIN EN 12831 Sisteme de incalzire<br />

Reguli pentru calcularea necesarului de energie<br />

termica a cladirilor.<br />

- VDI 2<strong>03</strong>5 Prevenirea deteriorarilor cauzate de coroziunea<br />

si depunerile de piatra pe instalatiile de apa calda.<br />

- VDE 0100<br />

- Prescriptiile pompierilor<br />

Calitatea apei<br />

Apa de incalzire (agent termic)<br />

- Trebuie respectata norma europeana EN 14868<br />

si directiva VDI 2<strong>03</strong>5. Trebuie respectate mai ales<br />

urmatoarele date:<br />

- Cazanele si boilerele Hoval sunt proiectate<br />

pentru instalatii de incalzire fara admisie semnificativa<br />

de oxigen (Tip instalatii I dupa EN 14868).<br />

- Instalatiile cu<br />

- instalatii cu admisie continua de oxigen (de ex.<br />

instalatii de incalzire prin pardoseala fara tevi de<br />

plastic etanse la difuzie sau vas de expansiune<br />

deschis) sau<br />

- instalatii cu admisie intermitenta de oxigen (de<br />

ex. sunt necesare completari dese)<br />

trebuie echipate cu un dispozitiv de separare a<br />

sistemului.<br />

- Apa de incalzire trebuie verificata cel putin 1 x pe an si<br />

chiar mai des în functie de prescriptiile producatorului<br />

inhibitorilor<br />

- Inainte de umplerea instalatiilor vechi si a instalatiilor<br />

noi este necesara o clatire corespunzatoare a<br />

sistemului de incalzire!<br />

- Cazanul poate fi umplut doar dupa ce a fost clatit<br />

sistemul de incalzire. Se aplica si pentru inlocuirea<br />

cazanului unei instalatii existente.<br />

cupru.<br />

- Valoarea pH-ului apei de incalzire ar trebui sa fie dupa<br />

6-12 saptamani de regim de incalzire intre 8,3 şi 9,5<br />

pentru nu se impiedica curgerea prin depuneri in urma<br />

coroziunii altor materiale din instalaţie.<br />

- Tinain cont de pericolul de coroziune punctiforma<br />

clorurile, nitratii si sulfatii continuti in apa nu trebuie sa<br />

depaseasca 200 mg/l in total.<br />

Apa de umplere şi completare:<br />

- De regula, cea mai potrivita apa de umplere si<br />

completare pentru cazanele HOVAL este apa potabila<br />

netratata. In orice caz, calitatea apei potabile netratate<br />

trebuie sa corespunda normei VDI 2<strong>03</strong>5 sau sa fie<br />

desalinizata si tratata corespunzator cu inhibitori.<br />

Pentru aceasta se vor respecta prescriptiile EN 14868.<br />

- Pentru a mentine randamentul ridicat al cazanului de<br />

incalzire si pentru a evita supraincalzirea suprafetelor<br />

de transfer termic nu trebuie depasita duritatea totala<br />

si volumul de apa din tabel in functie de puterea cazanului<br />

(cel mai mic cazan individual in cazul instalatiilor<br />

cu mai multe cazane).<br />

- Volumul total de apa de umplere si completare care<br />

se umple respectiv se completeaza in timpul duratei<br />

totale de viata a cazanului nu are voie sa depaseasca<br />

de trei ori volumul de apa al instalatiei.<br />

Camera de montare<br />

Cazanele nu pot fi montate in incaperi in care se formeaza<br />

halogeni care pot patrunde in aerul necesar arderii<br />

(de ex. spalatorii, uscatorii, incaperi destinate asamblarii,<br />

saloane de coafura s.a.m.d.).<br />

Halogenii se pot forma printre altele in urma utilizarii<br />

solutiilor de curatare, degresantilor, diluantilor, adezivilor<br />

si inalbitorilor.<br />

Aerul necesar arderii<br />

Trebuie asigurata alimentarea cu aer. A nu se obtura<br />

orificiul de admisie pentru aer.. Pentru alimentarea directa<br />

cu aerul de ardere (Sistem LAS) poate fi conectata o<br />

conducta de aer cu D=80 mm direct la cazan.<br />

Secţiunea minima libera pentru gura de aer poate fi calculata<br />

simplificat dupa cum urmeaza. Puterea nominala<br />

este esentiala!<br />

- Functionare dependenta de aerul ambiental:<br />

Pentru alimentarea cu aer este necesara o sectiune<br />

minima de 150 cm 2 sau doua de 75 cm 2 si in plus 2<br />

cm 2 pentru fiecare kW putere care depaseste 50 kW.<br />

- Funcţionarea independenta de aerul ambiental cu<br />

conducta separata de aer de ardere pentru cazan:<br />

0,8 cm 2 per 1 kW putere. La dimensionarea conductei<br />

de aer de ardere trebuie luata în considerare pierderea<br />

de presiune din sistemul de gaze arse.<br />

Racord gaze<br />

Punere in functiune<br />

- Prima punere in functiune poate fi executata numai<br />

de catre un specialist.<br />

- Valorile reglajelor arzatorului conform instructiunilor<br />

de instalare.<br />

Robinet manual de gaze si filtru de gaz<br />

Conform prevederilor locale trebuie montat un dispozitiv<br />

de inchidere pentru gaz (robinet) direct in fata cazanului.<br />

In cazul în care este necesar trebuie montat un filtru<br />

autorizat pentru gaze pe conducta de gaz între robinet<br />

si cazan, pentru a evita defectiunile cauzate de mizeria<br />

transportata in gaz.<br />

Tipul de gaz<br />

- Cazanele pot fi utilizate numai cu tipul de gaz indicat<br />

pe placuţa de identificare.<br />

- Pentru gaz lichefiat trebuie montat un regulator de<br />

presiune pentru gaz, pentru reducerea presiunii de<br />

alimentare a cazanului.<br />

Presiunea gazului<br />

Presiunea de curgere necesara la intrarea în cazan:<br />

gaze naturale min. 18 mbar, max. 50 mbar.<br />

gaz lichefiat min. 25 mbar, max. 50 mbar.<br />

Separator de impuritati<br />

Pe returul cazanului se recomanda montarea unui filtru<br />

de impuritati.<br />

Cantitatea minima de apa de incalzire recirculata<br />

- In functie de tipul cazanului este necesara recircularea<br />

de volume minime de apa de incalzire diferite .<br />

Pentru date vezi fisele de date corespunzatoare.<br />

- In timpul functionarii arzatorului trebuie sa functioneze<br />

continuu pompa de recirculare şi trebuie sa se<br />

asigure cantitatea minima de recirculare pentru apa<br />

de incalzire.<br />

Functionarea ulterioara a pompei (temporizare)<br />

- Dupa oprirea arzatorului trebuie sa mai functioneze<br />

pompa de circulatie cel putin inca 2 minute (este<br />

asigurat prin sistemul de comanda a cazanului cu<br />

regulator TopTronic).<br />

- Piesele cazanului care intra in contact cu apa sunt din<br />

Table 1: Volum maxim de umplere pe baza VDI 2<strong>03</strong>5<br />

Valabil pentru cazane cu < 0,3 l/kW volum de apa<br />

Duritate totala pentru apa de umplere pana la.....<br />

[mol/m 3 ] 1 3,0<br />

f°H 30<br />

d°H 16,8<br />

e°H 21,3<br />

~mg/l 300<br />

Conductibilitate 2 600<br />

Marimea cazanului<br />

individual<br />

volum maxim de umplere fara dedurificare<br />

pana la 28 kW Neprecizat 50 l/kW 20 l/kW<br />

1<br />

suma alcalina<br />

2<br />

Daca condubilitatea in µS/cm depaseste valoarea din tabel este necesara o verificare a apei.<br />

26<br />

Centrale si cazane murale<br />

Subject to modification, 1.4.20<strong>08</strong>


Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />

Proiectare<br />

Montarea cazanului in pod<br />

In cazul in care cazanul pe gaz tip <strong>TopGas</strong>® constituie<br />

o componenta a unei centrale termice montata in pod,<br />

trebuie sa se monteze un presostat de apa.<br />

Evacuarea condensului<br />

- Condensul din conducta de gaze arse poate fi evacuat<br />

prin cazan. Nu mai este necesar un sistem de<br />

separare a condensului in sistemul de conducte<br />

de gaze arse.<br />

- Autorizatia pentru evacuarea condensului, provenit<br />

de la gazele arse, in canalizare trebuie obtinuta de la<br />

societatea dvs. de salubrizare.<br />

- La scurgerea de condens din cazanul pe gaze<br />

trebuie montat un sifon (exista in pachetul cazanului).<br />

- Condensul trebuie evacuat liber (palnie)<br />

in canalizare.<br />

Cosul / Instalatia de evacuare a gazelor arse<br />

Cos utilizat separat<br />

- Cazanele pe gaz trebuie conectate la o instalatie de<br />

evacuare (cos sau conducta de gaze arse).<br />

- Conductele pentru gaze arse trebuie sa fie etanse la<br />

gaz, condens si presiune.<br />

- Cazanele pe gaz in condensatie trebuie conectate la o<br />

conducta de gaze arse cat. T120.<br />

- In cazan exista un limitator de temperatura pentru<br />

gaze arse.<br />

Vas de expansiune<br />

- Trebuie utilizat un vas de expansiune dimensionat<br />

corect.<br />

- Vasul de expansiune trebuie conectat la racordul<br />

existent pentru vasul de expansiune cu seturile de<br />

conectare 3,4 sau 10 (pe partea aspiratiei pompei).<br />

- Incepand cu 70°C este necesar sa se conecteze un<br />

vas intermediar de racire.<br />

Zgomot<br />

- Nivelul de zgomot este o marime independenta de<br />

conditiile locale si influentele camerei.<br />

- Nivelul de presiune fonica depinde de conditiile de<br />

montare si este posibil ca la o distanta de 1 m sa<br />

fie cu pana la 15 dB(A) mai scazut decat nivelul de<br />

zgomot<br />

Sisteme evacuare gaze arse<br />

Vezi capitolul Sisteme de evacuare pentru gaze arse<br />

Exemple de utilizare<br />

Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />

Cazane pe gaz cu<br />

- sistem de incalzire instant pentru apa calda integrat<br />

- un circuit de incalzire direct<br />

Plan hidraulic BCMT010<br />

BA<br />

RS<br />

- OT<br />

B 1<br />

T<br />

T<br />

WW<br />

Dies ist ein<br />

unerlaubter <strong>TopGas</strong> Weg!<br />

Gehen Sie einen<br />

Schritt <strong>combi</strong> zurück oder<br />

löschen Sie dieses<br />

Shape!<br />

Sie haben die<br />

Möglichkeit ein<br />

neues Shape zu<br />

nehmen!!!<br />

hovhovalhovalhoval<br />

hovalhovalhovalhov<br />

P<br />

RS-OT<br />

BA<br />

B1<br />

Staţie de camera (OpenTherm)<br />

Senzor de exterior<br />

Limitator de temperatura pentru circuitul tur<br />

(daca este nevoie)<br />

Gas<br />

KW<br />

Indicaţii importante :<br />

- Exemplele de utilizare sunt un plan de principiu care<br />

nu contine toate datele necesare pentru instalare.<br />

Instalarea se efectueaza in functie de conditiile de la<br />

fata locului, de dimensionare si normative.<br />

- Pentru sistemele de incalzire prin pardoseala trebuie<br />

montat un limitator de temperatura pe circuitul tur.<br />

- Trebuie asigurati robineti de inchidere a dispozitivelor<br />

de siguranta (vasul de expansiune, supapa de<br />

siguranta, s.a.m.d.) impotriva inchiderii accidentale!<br />

- Trebuie montati saci pentru evitarea circulatiei pe o<br />

singura conducta cauzata de gravitatie!<br />

Subject to modification, 1.4.20<strong>08</strong><br />

Centrale si cazane murale<br />

27


28<br />

Centrale si cazane murale

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!