RO_CAP01_03_TopGas_combi_08 .pdf - Energosistem - Materiale ...
RO_CAP01_03_TopGas_combi_08 .pdf - Energosistem - Materiale ...
RO_CAP01_03_TopGas_combi_08 .pdf - Energosistem - Materiale ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Centrala in condensatie pe gaz<br />
cu sistem de preparare ACM integrat<br />
Descriere<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />
(21/18, 26/23, 32/28)<br />
Centrala in condensatie pe gaz<br />
• Cu tehnica de condensatie<br />
• Schimbator de caldura din aliaj de aluminiu rezistent la<br />
coroziune cu sistem de circulatie fortata cu spirala de<br />
cupru.<br />
• Prepararea de ACM prin a doua spirala de cupru<br />
integrata in centrala.<br />
• Contine:<br />
- pompa pentru circuitul de incalzire<br />
- manometru electronic<br />
- aerisitor manual<br />
- limitator de temperatura gaze arse<br />
- fluxostat pe circuitul de ACM<br />
• Arzator cu preamestec din inox<br />
- Modulant cu controlarea raportului aer/gaz<br />
- Aprindere automata<br />
- Supraveghere flacara (ionizare)<br />
• Centrala pe gaz murala, montata in carcasa din tabla<br />
de otel vopsita in alb<br />
Panou de comanda al cazanului N4.4<br />
• Automat de ardere cu sistem de supraveghere BIC<br />
300<br />
• Comanda modulanta a arzatorului<br />
• Intrerupator electronic „I/O“<br />
• Afisare functionare si defectiuni<br />
• Comanda preparare apa calda cu fluxostat.<br />
• Cu posibilitatea de conectare a max. 1 statie de<br />
camera sau 1 telecomanda cu senzor de camera.<br />
Varinte configurabile<br />
• Robineti de gaz<br />
• Cu cadru de montaj<br />
• Cu cadru de montaj si vas de expansiune integrat<br />
• Seturi de conectare<br />
Livrare<br />
• Centrala murala montata in carcasa<br />
• Sistem de prindere si sifon de condens<br />
• Instructiuni de montaj<br />
• Instructiuni de utilizare<br />
Set regulator de incalzire RS-OT<br />
• Pentru 1 circuit de incalzire fara amestec<br />
• Reglarea temperaturii apei din cazan functie de<br />
temperatura exterioara<br />
• RS-OT cu posibilitatea de activare a senzorului<br />
ambiental de temperatura pentru camera, amplasare<br />
in camera centralei sau camera de zi<br />
• Senzor de exterior AF 120<br />
• Senzor de boiler TF 25 / 12K<br />
Nu poate fi montat in panoul centralei!<br />
<strong>TopGas</strong> ®<br />
Tip<br />
Putere incalzire<br />
kW<br />
<strong>combi</strong> (21/18) 5,9 - 18,6<br />
<strong>combi</strong> (26/23) 7,6 - 23,4<br />
<strong>combi</strong> (32/28) 7,8 - 27,1<br />
Certificarea cazanului<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28):<br />
CE-Product-ID-No.<br />
0063BQ3155<br />
Nota:<br />
<strong>TopGas</strong> ® <strong>combi</strong> poate fi utilizat numai daca apa<br />
potabila are o duritate mai mica de 13 germane<br />
(d°H).<br />
Subject to modification, 1.4.20<strong>08</strong><br />
Centrale si cazane murale<br />
19
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Coduri articole / Preturi<br />
Centrale murale pe gaz in condensatie<br />
<strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Coduri articole<br />
Schimbator de caldura din aliaj de aluminiu rezistent la<br />
coroziune cu sistem de circulatie fortata cu spirala de<br />
cupru. Prepararea api calde se realizeaza printr-o a doua<br />
integrata in centrala.<br />
Cu arzator modulant cu preamestec din inox, inclusiv<br />
sistemul de comanda de baza N4.4 al centralei, montat in<br />
carcasa.<br />
<strong>TopGas</strong> ® <strong>combi</strong><br />
Putere incalzire<br />
Tip kW 1<br />
<strong>combi</strong> (21/18) 5,9 - 18,6<br />
<strong>combi</strong> (26/23) 7,6 - 23,4<br />
<strong>combi</strong> (32/28) 7,8 - 27,1<br />
1<br />
kW = Interval de modulare la 40/30 °C<br />
70<strong>03</strong> 949<br />
70<strong>03</strong> 652<br />
70<strong>03</strong> 653<br />
1.751<br />
1.790<br />
1.854<br />
Nota:<br />
<strong>TopGas</strong> ® <strong>combi</strong> poate fi utilizat numai daca apa<br />
potabila are o duritate mai mica de 13 germane<br />
(d°H).<br />
Accesorii<br />
Set de modificare pentru gaz lichefiat<br />
<strong>TopGas</strong> ® <strong>combi</strong> (21/18) 2025 781<br />
<strong>TopGas</strong> ® <strong>combi</strong> (26/23, 32/28) 2025 782<br />
12<br />
12<br />
Piesa de racordare pentru gaze arse E80<br />
pentru separarea conductei de evacuare gaze arse de<br />
conducta de admisie aer de ardere. 2029 057<br />
46<br />
Aerisitor automat 3/8" 240 191<br />
13<br />
Consola pentru premontare<br />
Pentru preinstalarea racordurilor de gaz, tur si retur, apa<br />
rece si apa calda.<br />
Compatibila cu toate tipurile de cadre de montaj sau<br />
fara cadru de montaj!<br />
2025 779<br />
251<br />
Set de conexiune 3<br />
Pentru Hoval <strong>TopGas</strong> ® classic fara boiler, fara/ cu cadru<br />
de montaj.<br />
Compus din: conector gaz, conector tur, conector retur<br />
cu supapa diferentiala de presiune, supapa de siguranta<br />
3 bar, robinet de umplere/golire, racord conectare vas de<br />
expansiune, 2 robineti cu bila pe incalzire.<br />
Robineti cu filet interior tur/retur R 3/4““ 2001 257<br />
186<br />
Set extensie pentru circuitul sanitar<br />
2 piese<br />
Absolut necesar pentru montarea cu setul de<br />
conexiune 3 pentru <strong>TopGas</strong> ® <strong>combi</strong>.<br />
6016 874<br />
39<br />
20<br />
Centrale si cazane murale<br />
Subject to modification, 1.4.20<strong>08</strong>
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Coduri articole / Preturi<br />
Accesorii <strong>TopGas</strong> ® <strong>combi</strong><br />
Coduri articole<br />
Set de conectare jos<br />
(nu este posibila <strong>combi</strong>narea cu setul de conexiune 3)<br />
pentru Hoval <strong>TopGas</strong> ® <strong>combi</strong>, cu / fara cadru de montaj.<br />
Compus din: robinet de apa rece, supapa de siguranta<br />
pentru instalatia sanitara 8 bar, supapa de siguranta pentru<br />
incalzire 3 bar, robinet de umplere / golire, conectori<br />
cu inel de strangere D22 pentru tur si retur. 2022 914<br />
172<br />
Cadru de montaj MR50 fara vas de expansiune<br />
pentru marirea distantei fata de perete, pentru usurarea<br />
montajului (de ex.. piesa pentru gaze arse direct pe<br />
perete). Nu este strict necesar.<br />
<strong>TopGas</strong> ® <strong>combi</strong> (21/18) 2029 696<br />
<strong>TopGas</strong> ® <strong>combi</strong> (26/23) 2029 701<br />
43<br />
51<br />
<strong>TopGas</strong> ® <strong>combi</strong> (32/28) 2029 702<br />
55<br />
Cadru de montaj MR110 cu vas de expansiune si<br />
furtun flexibil pentru racordare la setul de conexiune<br />
3. Vasul de expansiune se conecteaza la setul de<br />
conectare jos, la montare!<br />
Cadru pentru prinderea centralei Hoval <strong>TopGas</strong> ®<br />
<strong>combi</strong> cu vas de expansiune integrat<br />
volum 12 l / pre-incarcare 0,75 bar<br />
<strong>TopGas</strong> ® <strong>combi</strong> (21/18) 6016 863<br />
<strong>TopGas</strong> ® <strong>combi</strong> (26/23) 6016 864<br />
<strong>TopGas</strong> ® <strong>combi</strong> (32/28) 6016 865<br />
238<br />
238<br />
238<br />
Masca pentru Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />
pentru acoperirea racordurilor de gaz, tur, retur la Top-<br />
Gas ® <strong>combi</strong> (21/18, 26/23, 32/28), in <strong>combi</strong>natie cu setul<br />
de conexiune 3<br />
Este posibila <strong>combi</strong>narea fara/ cu cadrul de montaj<br />
MR50/MR110. 3, precum si cu setul de conectare jos.<br />
2029 787<br />
39<br />
Set regulator de incalzire RS-OT<br />
(Nu este pt. sistem de functionare cu amestec!)<br />
Pentru 1 circuit fara amestec<br />
Reglarea temperaturii turului functie de temperatura<br />
exterioara cu senzor de exterior AF 120, water senzor de<br />
boiler TF 25 / 12K si cu posibilitatea activarii senzorului<br />
de interior. Poate fi utilizat si pentru reglarea temperaturii<br />
camerei fara senzor de exterior.<br />
Nu poate fi montat in panoul de comanda al centralei!<br />
6015 199<br />
238<br />
Subject to modification, 1.4.20<strong>08</strong><br />
Centrale si cazane murale<br />
21
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Coduri articole / Preturi<br />
Accesorii <strong>TopGas</strong> ® <strong>combi</strong><br />
Limitator de temperatura pentru circuitul de incalzire<br />
- pentru incalzirea in pardoseala (1 limitator pentru<br />
fiecare circuit)<br />
15-95 °C, differential gap 6K, tub capilar max. 700 mm,<br />
setare (vizibil din exterior) sub capacul carcasei.<br />
Coduri articole<br />
Termostat de contact RAK-TW1000.S<br />
Termostat cu colier de prindere, fara cablu si stecker 242 902<br />
68<br />
Robinet de gaz de trecere DN ½“<br />
(cu declansare termica) 2012 075<br />
43<br />
Robinet de gaz, varianta de colt DN ½“<br />
(cu declansare termica) 2012 076<br />
Conector cu inel de strangere nr. 1 (½“ AG x 15)<br />
pentru robinetul de gaz, apa calda sau apa rece<br />
cand nu se utilizeaza seturile de conexiune 3, consola<br />
pentru premontare sau setul de conectare jos. 2001 824<br />
51<br />
6<br />
Conector cu inel de strangere nr. 1 (¾" AG x 22)<br />
pentru tur si retur<br />
cand nu se utilizeaza seturile de conexiune 3, consola<br />
pentru premontare sau setul de conectare jos. 2029 325<br />
9<br />
Separator de impuritati<br />
DC 20 - ¾“<br />
DC 25 - 1“<br />
2029 530<br />
2029 531<br />
1<strong>08</strong><br />
1<strong>08</strong><br />
Aerisitor rapid cu blocare<br />
accesoriu pentru separatorul de impuritati 2002 582<br />
36<br />
Service<br />
Punere in functiune<br />
Punerea in functiune prin departamentul de service<br />
al Hoval <strong>RO</strong> sau printr-o firma specializata autorizata,<br />
constituie o premisa pentru acordarea garantiei.<br />
Pentru punerea in functiune si alte sevicii va rugam sa<br />
va adresati catre Hoval <strong>RO</strong>.<br />
22<br />
Centrale si cazane murale<br />
Subject to modification, 1.4.20<strong>08</strong>
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Date tehnice<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />
Tip (21/18) (26/23) (32/28)<br />
• Putere nominala 80/60 °C la gaze naturale 1 kW 5,4 - 17,8 6,9 - 22,8 7,1 - 26,3<br />
• Putere nominala 40/30 °C la gaze naturale 1 kW 5,9 - 18,6 7,6 - 23,4 7,8 - 27,1<br />
• Putere nominala 80/60 °C la propan 3 kW 5,7 - 17,8 7,3 - 22,8 7,3 - 26,3<br />
• Putere nominala 40/30 °C la propan 3 kW 6,3 - 18,6 8,0 - 23,4 8,0 - 27,4<br />
• Sarcina nominala la gaze naturale 1 kW 5,6 - 18,7 7,1 - 23,7 7,2 - 27,3<br />
• Sarcina nominala instalatie sanitara la gaze naturale 1 kW 5,6 - 22,1 7,1 - 28,0 7,5 - 32,7<br />
• Sarcina nominala la propan 3 kW 5,9 - 18,7 7,5 - 23,7 7,5 - 27,3<br />
• Presiune de lucru max./min. bar 3,0 / 1,0 3,0 / 1,0 3,0 / 1,0<br />
• Temperatura maxima de lucru °C 85 85 85<br />
• Volumul de apa al cazanului l 1,4 1,7 2,0<br />
• Debit minim circulatie apa in cazan l/h 180 180 180<br />
• Greutate cazan (fara apa) kg 34 38 42<br />
• Randamentul normat (DIN 4702, partea 8) 40/30 °C % 1<strong>08</strong> / 97,3 1<strong>08</strong> / 97,3 1<strong>08</strong> / 97,3<br />
(raportat la PCI / raportat la PCS) 75/60 °C % 1<strong>03</strong>,3 / 93,1 1<strong>03</strong>,3 / 93,1 1<strong>03</strong>,3 / 93,1<br />
• Pierderi de putere in stand-by la 70 °C Watt 60 80 95<br />
• Valoarea emisiilor standard<br />
Oxizi de azot NOx mg/kWh 35 60 66<br />
Monoxizi de carbon CO mg/kWh 65 65 65<br />
• Continut de CO 2<br />
in gazele arse putere max./min. % 9,0/8,8 9,0/8,8 9,0/8,8<br />
• Dimensiuni:<br />
Vezi subcapitolul Dimensiuni<br />
• Racorduri<br />
Tur / Retur D22 D22 D22<br />
Apa rece / Apa calda D15 D15 D15<br />
Gaz D15 D15 D15<br />
Gaze arse / aer de ardere (concentric) mm 80/125 80/125 80/125<br />
suplimentar pentru alimentarea directa cu aer de ardere mm 80 80 80<br />
• Presiune curgere gaze min./ max.<br />
gaze naturale E/LL mbar 18 - 50 18 - 50 18 - 50<br />
propan mbar 25 - 50 25 - 50 25 - 50<br />
• Consum de gaze (puterea gazului la 0 °C / 1013 mbar):<br />
Gaz natural E - (Wo = 15,0 kWh/m 3 ) H u<br />
= 9,97 kWh/m 3 m 3 /h 1,87 2,37 2,73<br />
Gaz natural LL- (Wo = 12,4 kWh/m 3 ) H u<br />
= 8,57 kWh/m 3 m 3 /h 2,18 2,77 3,19<br />
Propan 3 (H u<br />
= 25,9 kWh/m 3 ) m 3 /h 0,72 0,92 1,05<br />
• Tensiune de lucru V/Hz 230 / 50 230 / 50 230 / 50<br />
• Consum electric min./max. (inclusiv pompa) Watt 13 / 85 13 / 89 13 / 95<br />
• Tip protectie IPx2D 40 40 40<br />
• Nivel de zgomot dB(A) 56 56 57<br />
• Nivelul de presiune fonica<br />
dB(A) 45 45 46<br />
(depinde de conditiile de montare) 2<br />
• Cantitatea de condens (gaze naturale) la 40 / 30 °C l/h 1,8 2,2 2,6<br />
• Valoare pH a condensului ca. 4,2 ca. 4,2 ca. 4,2<br />
• Valori pentru calculul cosului de fum<br />
Tip clasa de temperatura pentru gaze arse T 120 T 120 T 120<br />
Debitul masic al gazelor arse kg/h 31,0 39,3 45,3<br />
Temperatura gazelor arse functionare la 80/60 °C °C 85 85 85<br />
Temperatura gazelor arse functionare la 40/30 °C °C 64 64 64<br />
Presiunea disponibila pentru alimentare aer / evacuare gaze arse Pa 75 75 75<br />
Depresiunea maxima pe conducta de evacuare Pa - 50 - 50 - 50<br />
1<br />
Date raportate la H u<br />
. Seria cazanelor este testata pentru EE/H. Cu setarile din fabrica a coeficientului Wobbe de 15,0 kWh/m3 este posibila functionarea la un coeficient Wobbe<br />
de la 12,0 pana la 15 , 7 kWh/m3 fara setari noi.<br />
2<br />
Vezi si indicatiile de proiectare<br />
3<br />
Cazanele <strong>TopGas</strong> ® <strong>combi</strong> pot fi utilizate si pentru amestecuri de Propan / Butan (gaz lichefiat).<br />
Subject to modification, 1.4.20<strong>08</strong><br />
Centrale si cazane murale<br />
23
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Date tehnice<br />
Inaltimea maxima de pompare<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18)<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (26/23)<br />
Inaltimea de pompare (mbar)<br />
600<br />
550<br />
500<br />
3<br />
450<br />
400<br />
350<br />
2<br />
300<br />
250<br />
200<br />
1<br />
150<br />
100<br />
50<br />
0<br />
0 250 500 750 1000 1250 1500 1750 2000<br />
Inaltimea de pompare (mbar)<br />
600<br />
550<br />
500<br />
3<br />
450<br />
400<br />
2<br />
350<br />
300<br />
250<br />
200<br />
1<br />
150<br />
100<br />
50<br />
0<br />
0 250 500 750 1000 1250 1500 1750 2000<br />
Debit (l/h)<br />
Debit (l/h)<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (32/28)<br />
Inaltimea de pompare (mbar)<br />
600<br />
550<br />
500<br />
450<br />
3<br />
400<br />
350<br />
2<br />
300<br />
250<br />
200<br />
1<br />
150<br />
100<br />
50<br />
0<br />
0 250 500 750 1000 1250 1500 1750 2000<br />
Debit (l/h)<br />
1 Treapta 1<br />
2 Treapta 2<br />
3 Treapta 3<br />
Putere încalzire apa cu <strong>TopGas</strong> ® <strong>combi</strong><br />
Pierderi de putere in<br />
Putere incalzire apa<br />
stand-by qB<br />
<strong>TopGas</strong> ® <strong>combi</strong> dm 3 /10 min 1 dm 3 /h 2 dm 3 /10 min 1 dm 3 /h 2 Debitul max. Numar 3 (70 °C)<br />
Tip 40 °C 40 °C 45 °C 45 °C dm 3 /10 min de locuinte Watt<br />
(21/18) 97 579 83 497 60 1 60<br />
(26/23) 126 759 1<strong>08</strong> 650 80 1 80<br />
(32/28) 145 869 124 745 95 1 95<br />
1<br />
Debit de apa calda (pe termen scurt ) 10 min. conform regurilor de verificare Procal<br />
Valorile pot fi obtinute doar prin controlul debitului si a temperaturii apei reci de intrare!<br />
2<br />
Debit de apa calda pe ora conform regurilor de verificare Procal.<br />
Valorile pot fi obtinute doar prin controlul debitului si a temperaturii apei reci de intrare!<br />
3<br />
Locuinta (3-4 camere cu 3-4 persoane,1 cada cu cca. 150 litri, 1 chiuveta, 1 lavoar)<br />
Nota:<br />
<strong>TopGas</strong> ® <strong>combi</strong> poate fi utilizat doar daca duritatea<br />
apei reci este sub<br />
13 d°H (grade germane).<br />
24<br />
Centrale si cazane murale<br />
Subject to modification, 1.4.20<strong>08</strong>
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Dimensiuni<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Dimensiuni minime<br />
(Valori in mm)<br />
• Lateral 50 mm<br />
• Distanta fata de tavan depinde<br />
de sistemul de evacuare<br />
a gazelor arse utilizate<br />
• In fata 500 mm<br />
(apa calda/ rece)<br />
(tur, retur, gaz)<br />
Conducta flexibila d 25<br />
<strong>TopGas</strong> ® <strong>combi</strong><br />
Tip a b1 b2 d e f g h i k l m<br />
(21/18) 590 460 0 50 75 185 170 65 247 – 30<br />
(21/18) cu cadrul de montaj (MR50) 590 574 50 100 125 235 220 115 297 834 80<br />
(21/18) cu cadrul de montaj cu vas de expansiune (MR110) 590 574 110 160 185 295 280 175 357 590 140<br />
(26/23) 650 520 0 50 75 185 170 65 247 – 30<br />
(26/23) cu cadrul de montaj (MR50) 650 634 50 100 125 235 220 115 297 894 80<br />
(26/23) cu cadrul de montaj cu vas de expansiune (MR110) 650 634 110 160 185 295 280 175 357 650 140<br />
(32/28) 710 580 0 50 75 185 170 65 247 – 30<br />
(32/28) cu cadrul de montaj (MR50) 710 694 50 100 125 235 220 115 297 954 80<br />
(32/28) cu cadrul de montaj cu vas de expansiune (MR110) 710 694 110 160 185 295 280 175 357 710 140<br />
1 Racord gaz D15<br />
(pentru conector Rp ½“ cu inel de strangere)<br />
2 Racord retur D22<br />
(pentru conector Rp ¾“ cu inel de strangere)<br />
3 Racord tur D22<br />
(pentru conector Rp ¾“ cu inel de strangere)<br />
4 Racord apa calda D15<br />
(pentru conector Rp ½“ cu inel de strangere)<br />
5 Racord apa rece D15<br />
(pentru conector Rp ½“ cu inel de strangere)<br />
6 Racord concentric pentru gaze arse si alimentare<br />
aer C80/125 incl. orificiu de masura<br />
6a Racord simplu pentru gaze arse E80 (optional)<br />
7 Alimentare cu aer din exterior D80<br />
8 Racord pentru evacuarea condensului<br />
Ø 32 mm (racord D25/21)<br />
9 Sifon<br />
10 Cadrul de montaj, latime 50 mm sau<br />
110 mm cu vas de expansiune<br />
opţional, vezi accesorii<br />
11a Loc pentru gaurire D10 fara cadrul de montaj<br />
11b Loc pentru gaurire D10 cu cadrul de montaj<br />
Subject to modification, 1.4.20<strong>08</strong><br />
Centrale si cazane murale<br />
25
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Proiectare<br />
Prescriptii si directive<br />
Trebuie respectate urmatoarele prescriptii si directive:<br />
- Informatiile tehnice si instructiunile de montare Hoval.<br />
- Prescriptiile hidraulice si normele tehnice ale firmei<br />
Hoval.<br />
- Prescriptiile ISCIR<br />
- Prescriptiile pompierilor<br />
- Directivele DVGW.<br />
- DIN EN 12828<br />
Cerinte tehnice de siguranta.<br />
- DIN EN 12831 Sisteme de incalzire<br />
Reguli pentru calcularea necesarului de energie<br />
termica a cladirilor.<br />
- VDI 2<strong>03</strong>5 Prevenirea deteriorarilor cauzate de coroziunea<br />
si depunerile de piatra pe instalatiile de apa calda.<br />
- VDE 0100<br />
- Prescriptiile pompierilor<br />
Calitatea apei<br />
Apa de incalzire (agent termic)<br />
- Trebuie respectata norma europeana EN 14868<br />
si directiva VDI 2<strong>03</strong>5. Trebuie respectate mai ales<br />
urmatoarele date:<br />
- Cazanele si boilerele Hoval sunt proiectate<br />
pentru instalatii de incalzire fara admisie semnificativa<br />
de oxigen (Tip instalatii I dupa EN 14868).<br />
- Instalatiile cu<br />
- instalatii cu admisie continua de oxigen (de ex.<br />
instalatii de incalzire prin pardoseala fara tevi de<br />
plastic etanse la difuzie sau vas de expansiune<br />
deschis) sau<br />
- instalatii cu admisie intermitenta de oxigen (de<br />
ex. sunt necesare completari dese)<br />
trebuie echipate cu un dispozitiv de separare a<br />
sistemului.<br />
- Apa de incalzire trebuie verificata cel putin 1 x pe an si<br />
chiar mai des în functie de prescriptiile producatorului<br />
inhibitorilor<br />
- Inainte de umplerea instalatiilor vechi si a instalatiilor<br />
noi este necesara o clatire corespunzatoare a<br />
sistemului de incalzire!<br />
- Cazanul poate fi umplut doar dupa ce a fost clatit<br />
sistemul de incalzire. Se aplica si pentru inlocuirea<br />
cazanului unei instalatii existente.<br />
cupru.<br />
- Valoarea pH-ului apei de incalzire ar trebui sa fie dupa<br />
6-12 saptamani de regim de incalzire intre 8,3 şi 9,5<br />
pentru nu se impiedica curgerea prin depuneri in urma<br />
coroziunii altor materiale din instalaţie.<br />
- Tinain cont de pericolul de coroziune punctiforma<br />
clorurile, nitratii si sulfatii continuti in apa nu trebuie sa<br />
depaseasca 200 mg/l in total.<br />
Apa de umplere şi completare:<br />
- De regula, cea mai potrivita apa de umplere si<br />
completare pentru cazanele HOVAL este apa potabila<br />
netratata. In orice caz, calitatea apei potabile netratate<br />
trebuie sa corespunda normei VDI 2<strong>03</strong>5 sau sa fie<br />
desalinizata si tratata corespunzator cu inhibitori.<br />
Pentru aceasta se vor respecta prescriptiile EN 14868.<br />
- Pentru a mentine randamentul ridicat al cazanului de<br />
incalzire si pentru a evita supraincalzirea suprafetelor<br />
de transfer termic nu trebuie depasita duritatea totala<br />
si volumul de apa din tabel in functie de puterea cazanului<br />
(cel mai mic cazan individual in cazul instalatiilor<br />
cu mai multe cazane).<br />
- Volumul total de apa de umplere si completare care<br />
se umple respectiv se completeaza in timpul duratei<br />
totale de viata a cazanului nu are voie sa depaseasca<br />
de trei ori volumul de apa al instalatiei.<br />
Camera de montare<br />
Cazanele nu pot fi montate in incaperi in care se formeaza<br />
halogeni care pot patrunde in aerul necesar arderii<br />
(de ex. spalatorii, uscatorii, incaperi destinate asamblarii,<br />
saloane de coafura s.a.m.d.).<br />
Halogenii se pot forma printre altele in urma utilizarii<br />
solutiilor de curatare, degresantilor, diluantilor, adezivilor<br />
si inalbitorilor.<br />
Aerul necesar arderii<br />
Trebuie asigurata alimentarea cu aer. A nu se obtura<br />
orificiul de admisie pentru aer.. Pentru alimentarea directa<br />
cu aerul de ardere (Sistem LAS) poate fi conectata o<br />
conducta de aer cu D=80 mm direct la cazan.<br />
Secţiunea minima libera pentru gura de aer poate fi calculata<br />
simplificat dupa cum urmeaza. Puterea nominala<br />
este esentiala!<br />
- Functionare dependenta de aerul ambiental:<br />
Pentru alimentarea cu aer este necesara o sectiune<br />
minima de 150 cm 2 sau doua de 75 cm 2 si in plus 2<br />
cm 2 pentru fiecare kW putere care depaseste 50 kW.<br />
- Funcţionarea independenta de aerul ambiental cu<br />
conducta separata de aer de ardere pentru cazan:<br />
0,8 cm 2 per 1 kW putere. La dimensionarea conductei<br />
de aer de ardere trebuie luata în considerare pierderea<br />
de presiune din sistemul de gaze arse.<br />
Racord gaze<br />
Punere in functiune<br />
- Prima punere in functiune poate fi executata numai<br />
de catre un specialist.<br />
- Valorile reglajelor arzatorului conform instructiunilor<br />
de instalare.<br />
Robinet manual de gaze si filtru de gaz<br />
Conform prevederilor locale trebuie montat un dispozitiv<br />
de inchidere pentru gaz (robinet) direct in fata cazanului.<br />
In cazul în care este necesar trebuie montat un filtru<br />
autorizat pentru gaze pe conducta de gaz între robinet<br />
si cazan, pentru a evita defectiunile cauzate de mizeria<br />
transportata in gaz.<br />
Tipul de gaz<br />
- Cazanele pot fi utilizate numai cu tipul de gaz indicat<br />
pe placuţa de identificare.<br />
- Pentru gaz lichefiat trebuie montat un regulator de<br />
presiune pentru gaz, pentru reducerea presiunii de<br />
alimentare a cazanului.<br />
Presiunea gazului<br />
Presiunea de curgere necesara la intrarea în cazan:<br />
gaze naturale min. 18 mbar, max. 50 mbar.<br />
gaz lichefiat min. 25 mbar, max. 50 mbar.<br />
Separator de impuritati<br />
Pe returul cazanului se recomanda montarea unui filtru<br />
de impuritati.<br />
Cantitatea minima de apa de incalzire recirculata<br />
- In functie de tipul cazanului este necesara recircularea<br />
de volume minime de apa de incalzire diferite .<br />
Pentru date vezi fisele de date corespunzatoare.<br />
- In timpul functionarii arzatorului trebuie sa functioneze<br />
continuu pompa de recirculare şi trebuie sa se<br />
asigure cantitatea minima de recirculare pentru apa<br />
de incalzire.<br />
Functionarea ulterioara a pompei (temporizare)<br />
- Dupa oprirea arzatorului trebuie sa mai functioneze<br />
pompa de circulatie cel putin inca 2 minute (este<br />
asigurat prin sistemul de comanda a cazanului cu<br />
regulator TopTronic).<br />
- Piesele cazanului care intra in contact cu apa sunt din<br />
Table 1: Volum maxim de umplere pe baza VDI 2<strong>03</strong>5<br />
Valabil pentru cazane cu < 0,3 l/kW volum de apa<br />
Duritate totala pentru apa de umplere pana la.....<br />
[mol/m 3 ] 1 3,0<br />
f°H 30<br />
d°H 16,8<br />
e°H 21,3<br />
~mg/l 300<br />
Conductibilitate 2 600<br />
Marimea cazanului<br />
individual<br />
volum maxim de umplere fara dedurificare<br />
pana la 28 kW Neprecizat 50 l/kW 20 l/kW<br />
1<br />
suma alcalina<br />
2<br />
Daca condubilitatea in µS/cm depaseste valoarea din tabel este necesara o verificare a apei.<br />
26<br />
Centrale si cazane murale<br />
Subject to modification, 1.4.20<strong>08</strong>
Hoval <strong>TopGas</strong> ® <strong>combi</strong> (21/18, 26/23, 32/28)<br />
Proiectare<br />
Montarea cazanului in pod<br />
In cazul in care cazanul pe gaz tip <strong>TopGas</strong>® constituie<br />
o componenta a unei centrale termice montata in pod,<br />
trebuie sa se monteze un presostat de apa.<br />
Evacuarea condensului<br />
- Condensul din conducta de gaze arse poate fi evacuat<br />
prin cazan. Nu mai este necesar un sistem de<br />
separare a condensului in sistemul de conducte<br />
de gaze arse.<br />
- Autorizatia pentru evacuarea condensului, provenit<br />
de la gazele arse, in canalizare trebuie obtinuta de la<br />
societatea dvs. de salubrizare.<br />
- La scurgerea de condens din cazanul pe gaze<br />
trebuie montat un sifon (exista in pachetul cazanului).<br />
- Condensul trebuie evacuat liber (palnie)<br />
in canalizare.<br />
Cosul / Instalatia de evacuare a gazelor arse<br />
Cos utilizat separat<br />
- Cazanele pe gaz trebuie conectate la o instalatie de<br />
evacuare (cos sau conducta de gaze arse).<br />
- Conductele pentru gaze arse trebuie sa fie etanse la<br />
gaz, condens si presiune.<br />
- Cazanele pe gaz in condensatie trebuie conectate la o<br />
conducta de gaze arse cat. T120.<br />
- In cazan exista un limitator de temperatura pentru<br />
gaze arse.<br />
Vas de expansiune<br />
- Trebuie utilizat un vas de expansiune dimensionat<br />
corect.<br />
- Vasul de expansiune trebuie conectat la racordul<br />
existent pentru vasul de expansiune cu seturile de<br />
conectare 3,4 sau 10 (pe partea aspiratiei pompei).<br />
- Incepand cu 70°C este necesar sa se conecteze un<br />
vas intermediar de racire.<br />
Zgomot<br />
- Nivelul de zgomot este o marime independenta de<br />
conditiile locale si influentele camerei.<br />
- Nivelul de presiune fonica depinde de conditiile de<br />
montare si este posibil ca la o distanta de 1 m sa<br />
fie cu pana la 15 dB(A) mai scazut decat nivelul de<br />
zgomot<br />
Sisteme evacuare gaze arse<br />
Vezi capitolul Sisteme de evacuare pentru gaze arse<br />
Exemple de utilizare<br />
Hoval <strong>TopGas</strong> ® <strong>combi</strong><br />
Cazane pe gaz cu<br />
- sistem de incalzire instant pentru apa calda integrat<br />
- un circuit de incalzire direct<br />
Plan hidraulic BCMT010<br />
BA<br />
RS<br />
- OT<br />
B 1<br />
T<br />
T<br />
WW<br />
Dies ist ein<br />
unerlaubter <strong>TopGas</strong> Weg!<br />
Gehen Sie einen<br />
Schritt <strong>combi</strong> zurück oder<br />
löschen Sie dieses<br />
Shape!<br />
Sie haben die<br />
Möglichkeit ein<br />
neues Shape zu<br />
nehmen!!!<br />
hovhovalhovalhoval<br />
hovalhovalhovalhov<br />
P<br />
RS-OT<br />
BA<br />
B1<br />
Staţie de camera (OpenTherm)<br />
Senzor de exterior<br />
Limitator de temperatura pentru circuitul tur<br />
(daca este nevoie)<br />
Gas<br />
KW<br />
Indicaţii importante :<br />
- Exemplele de utilizare sunt un plan de principiu care<br />
nu contine toate datele necesare pentru instalare.<br />
Instalarea se efectueaza in functie de conditiile de la<br />
fata locului, de dimensionare si normative.<br />
- Pentru sistemele de incalzire prin pardoseala trebuie<br />
montat un limitator de temperatura pe circuitul tur.<br />
- Trebuie asigurati robineti de inchidere a dispozitivelor<br />
de siguranta (vasul de expansiune, supapa de<br />
siguranta, s.a.m.d.) impotriva inchiderii accidentale!<br />
- Trebuie montati saci pentru evitarea circulatiei pe o<br />
singura conducta cauzata de gravitatie!<br />
Subject to modification, 1.4.20<strong>08</strong><br />
Centrale si cazane murale<br />
27
28<br />
Centrale si cazane murale