RELEE TERMICE<br />

SIGURANŢE PENTRU RELEE TERMICE TIP U3/32, U12/16E, U3/42, U3/74 ŞI U85<br />

DOMENIU REGLAJ<br />

VALOARE MAXIMĂ SIGURANŢĂ ÎN FUNCŢIE DE TIP CSA UL<br />

TIP<br />

PORN. DIRECTĂ<br />

A<br />

PORNIRE YD<br />

A<br />

“2” 1)<br />

rapidã<br />

A<br />

lentã<br />

gL(gG)<br />

A<br />

“1” 1)<br />

lentã gL(gG)<br />

A<br />

aM<br />

A<br />

A<br />

Tip<br />

A<br />

0.12 - 0.18 -<br />

0.18 - 0.27 -<br />

0.27 - 0.4 -<br />

0,5 2)<br />

1,0 2)<br />

2<br />

0,5 2)<br />

1,0 2)<br />

2<br />

25<br />

25<br />

25<br />

-<br />

-<br />

-<br />

0,5 2)<br />

1,0 2)<br />

2<br />

15<br />

15<br />

15<br />

0.4 - 0.6 -<br />

0.6 - 0.9 -<br />

0.8 - 1.2 -<br />

2<br />

4<br />

4<br />

2<br />

4<br />

4<br />

25<br />

25<br />

25<br />

-<br />

-<br />

2<br />

2<br />

4<br />

4<br />

15<br />

15<br />

15<br />

U3/32<br />

(U12/16E)<br />

1.2 - 1.8 -<br />

1.8 - 2.7 -<br />

2.7 - 4 -<br />

6<br />

10<br />

16<br />

6<br />

10<br />

10<br />

25<br />

25<br />

25<br />

2<br />

4<br />

4<br />

6<br />

10<br />

15<br />

HRC<br />

Form II<br />

15<br />

15<br />

15<br />

4 - 6 7 - 10.5<br />

6 - 9 10.5 - 15.5<br />

8 - 11 14 - 19<br />

20<br />

35<br />

35<br />

16<br />

25<br />

25<br />

25<br />

35<br />

35<br />

6<br />

10<br />

16<br />

20<br />

35<br />

40<br />

15<br />

25<br />

30<br />

250<br />

10 - 14 18 - 24<br />

13 - 18 23 - 31<br />

17 - (23)24 30 - (40)41<br />

(22)23 - (30)32 (38)40 - (52)55<br />

50<br />

50<br />

63<br />

80<br />

35<br />

35<br />

50<br />

63<br />

63<br />

63<br />

63<br />

80<br />

16<br />

20<br />

25<br />

35<br />

50<br />

60<br />

80<br />

-<br />

40<br />

50<br />

60<br />

-<br />

U3/42<br />

10 - 14 18 - 24<br />

14 - 20 24 - 35<br />

20 - 28 35 - 48<br />

28 - 42 48 - 52<br />

50<br />

63<br />

80<br />

100<br />

35<br />

50<br />

63<br />

80<br />

80<br />

80<br />

80<br />

150<br />

16<br />

25<br />

35<br />

50<br />

50<br />

80<br />

100<br />

125<br />

OTS-K5<br />

40<br />

60<br />

80<br />

110<br />

U3/74<br />

U85<br />

U205, U310,<br />

U840, U1250<br />

20 - 28 35 - 48<br />

28 - 42 48 - 73<br />

40 - 52 70 - 90<br />

52 - 65 90 - 112<br />

60 - 74 104 - 128<br />

60 - 90 104 - 156<br />

80 - 120 140 - 207<br />

toate domeniile<br />

toate domeniile<br />

100<br />

125<br />

160<br />

160<br />

160<br />

80<br />

100<br />

100<br />

125<br />

125<br />

150<br />

150<br />

150<br />

150<br />

150<br />

35<br />

50<br />

63<br />

80<br />

80<br />

Protecţia la scurcircuit a releului termic cu transformator<br />

de curent se alege corelat cu contactoarele din grupul<br />

de pornire al motorului.<br />

100<br />

125<br />

175<br />

200<br />

-<br />

300<br />

-<br />

OTS-K5<br />

OTS-K5<br />

80<br />

110<br />

200<br />

250<br />

250<br />

Protecţia la scurcircuit a releului termic cu transformator de curent se alege corelat cu<br />

contactoarele din grupul de pornire al motorului.<br />

300<br />

-<br />

CARACTERISTICI DE DECLANŞARE ALE RELEELOR TERMICE U3/32, U3/42, U3/74 ŞI<br />

U12/16E<br />

SARCINÃ TRIFAZICÃ<br />

timp de deconectare<br />

SARCINÃ BIFAZICÃ<br />

timp de deconectare<br />

Caracteristică<br />

tipică pentru<br />

starea rece<br />

Caracteristică<br />

tipică pentru<br />

starea rece<br />

La temperatura de<br />

funcţionare timpii de<br />

deconectare se<br />

micşorează la<br />

20-30%.<br />

La temperatura de<br />

funcţionare timpii de<br />

deconectare se<br />

micşorează la<br />

70-80%<br />

Curent reglat I e<br />

1) Tipul de coordonare conform IEC 947-4-1:<br />

“2”: sudură slabă la contactele contactorului, releul termic nevătămat<br />

“1”: sudură la contactele contactorului, posibile întreruperi în releul termic<br />

2) Siguranţă “fină”<br />

K = I max /I e<br />

I max = curent de fază maxim<br />

I e = limita superioară a<br />

domeniului de reglaj<br />