2-2<br />
A-6<br />
1'-6"<br />
5' X 4'<br />
XO<br />
3' X 6'-8"<br />
XO TEMP OBS<br />
4' X 2'<br />
XO<br />
5' X 4'<br />
5' X 4'<br />
XO<br />
2'-4" X 6'-8"<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
1'-6"<br />
25'-1" 24'-5" 5' 9'-7"<br />
20'-8" 4'-4" 2'-7" 10' 11'-10" 5' 9'-7"<br />
20'<br />
23'-4"<br />
5'-4"<br />
2'<br />
11'-2"<br />
7<br />
1'-4"<br />
4"<br />
DROP<br />
5'-2"<br />
4"<br />
DROP<br />
26'-3" 28'-4"<br />
5'-8"<br />
64'-1"<br />
2'-10" 8' 1'-9"<br />
CEILING<br />
BREAK LINE<br />
17'-7" 8'-8" 14'-7" 13'-9"<br />
64'-1"<br />
4'<br />
8'-1" 5'-6" 11'-5"<br />
16'-7"<br />
UP<br />
CLOSET<br />
26'-7"<br />
12<br />
11<br />
10<br />
9<br />
2'-6" X 6'-8"<br />
6'-4"<br />
FIREPLACE<br />
RF<br />
19'-3"<br />
4"<br />
DROP<br />
3' X 4'<br />
FX<br />
4"<br />
DROP<br />
2-2<br />
A-6<br />
KEY NOTES:<br />
KITCHEN:<br />
4' 2' 40'<br />
46'<br />
8'-3" 11'-1" 5'-10" 8'-10" 6'<br />
1<br />
2<br />
3<br />
STAIRS DOWN:<br />
6 1/2" RISE<br />
10" RUN<br />
(3 STEPS)<br />
DOWN<br />
10' X 8' PD<br />
23<br />
27'-7"<br />
XO<br />
5' X 4'<br />
NOOK<br />
9' CEILING<br />
XO<br />
5' X 4'<br />
6'-3" 3'-3" 2'-1"<br />
1<br />
2<br />
3<br />
DOWN<br />
STAIRS DOWN:<br />
6 1/2" RISE<br />
10" RUN<br />
(3 STEPS)<br />
23<br />
1. SINK WITH GARBAGE DISPOSAL.<br />
2. DISHWASHER, PROVIDE SURFACE MOUNT AIR GAP AS REQ'D.<br />
3. 24" COOKTOP (VENT TO EXTERIOR REQ.) (FAN TO HAVE 100 CFMS MIN REQUIRED)<br />
4. 36" REFRIGERATOR<br />
5. MICROWAVE & OVEN<br />
BATH:<br />
6. FIBERGLASS SHOWER PAN OVER WATERPROOF<br />
MEMBRANE, SLOPE TO DRAIN<br />
7. 5'X2'6" TUB/SHOWER<br />
8. 5'X5' BUILT OUT TUBE<br />
9. EXHAUST FAN AS REQUIRED BY CRC 303.3<br />
10. 2" DEPRESSED SHOWER PAN. GLASS SHOWER ENCLOSURE TO<br />
START FROM FLOOR TILE TO NO CURB.<br />
11. GLASS SLAYDER DOOR<br />
LAUNDRY:<br />
12 . FAN (RATED RUN CONTINUOUSLY ) LABEL THE SWITCH TO INDICATE THE<br />
OWNER SHOULD LEAVE IT ON ALL THE TIME . REG FOR WHOLE HOUSE<br />
VENTILATION .<br />
13. WASHER (F.B.O) RECESS ROUGH-IN PLUMBING AND DRYER (F.B.O.) PROVIDE<br />
EXHAUST VENT TO OUTSIDE AIR WITH AIR DAMPER SEE DETAIL 15/AD2 VERIFY<br />
MAKE-UP AIR REQUIREMENT PER CMC 905.3 (B)<br />
GARAGE ANG STAIRS:<br />
14. AUTO DOOR OPENER (PROVIDE ELECT AS REQ)<br />
15. 1-3/8" SOLID CORE, SELF CLOSING DOOR REQ FOR OPENINGS BETWEEN GARAGE<br />
AND DWELLING. (CRC 302.5.1)<br />
16. 5/8" TYPE X DRYWALL AT WALLS AND CEILING BETWEEN DWELLING AND GARAGE,<br />
AND AT ALL EXPOSED STRUCTURAL MEMBERS. AT GARAGE CEILING WHERE<br />
THERE IS LIVING SPACE ABOVE AND AT ALL ACCESSIBLE AREAS UNDER ALL<br />
STAIRS USE (1) LAYERS OF 5/8" TYPE X DRYWALL. (TABLE R302.6)<br />
17. CONCRETE LANDING TO GRADE AS REQ.<br />
FAMILY ROOM<br />
9' CEILING<br />
6' X 8' PD<br />
ATTIC:<br />
18. MIN. 24"X30" SQ. ATTIC ACCESS W/SWITCH/LIGHT PER U.M.C<br />
19. ATTIC MOUNTED FAU<br />
20<br />
22<br />
15'-9" 11'-7" 11'-1"<br />
10' 1'-11"<br />
2<br />
1<br />
3<br />
KITCHEN<br />
9' CEILING<br />
5<br />
4<br />
DINING ROOM<br />
VOLUME CEILING<br />
9' PLT.HGT.<br />
4/12 SLOPE<br />
MECHANICAL:<br />
20. AIR CONDITIONING COMPRESSOR WITH PAD AS REQ 12"<br />
AIRSPACE REQ ALL SIDES OF COMPRESSOR UNIT VERIFY UNIT<br />
SIZE WITH HVAC CONTRACTOR (CRC 314.4, CRC 315.1 AND CRC<br />
315.2<br />
21. TANK WATER HEATER IN GARAGE . (SEE T-24 FOR SPEC). PROVIDE DRAIN LINE<br />
FROM RELIEF VALVE TO THE OUTSIDE OF THE BUILDING WITH THE END OF THE<br />
PIPE NOT MORE THAN 2' OR CLOSER THAN 6" TO EXTERIOR GRADE. (CPC 504.6).<br />
22. 48" DIRECT VENT GAS FIREPLACE; FIREPLACE: 48"WX35"H ON TOP OF SILL<br />
PLATE, NICHE ABOVE FIREPLACE 36"WX7"HX4"D 66"FF<br />
FRAMING:<br />
23. GUARD RAILING MIN. HEIGHT 42"<br />
GENERAL NOTES:<br />
1-1<br />
A-6<br />
SPACE FOR<br />
ELECTRICAL PANEL<br />
17<br />
4" DROP<br />
WH<br />
21<br />
7<br />
GARAGE DOOR<br />
16' X 6'-8"<br />
BEDROOM 1<br />
9' CEILING<br />
7'-4"<br />
6' X 6'-8"<br />
11'-7"<br />
BATH 1<br />
9' CEILING<br />
11'-1"<br />
GARAGE<br />
9' CEILING<br />
16<br />
SLOPE<br />
2% MIN.<br />
2'-6" X 6'-8"<br />
2'-6" X 6'-8"<br />
4<br />
3<br />
2<br />
1<br />
4'<br />
3'-10"<br />
HALL<br />
9' CEILING<br />
15<br />
3' X 6'-8"<br />
3' X 6'-8"<br />
UP<br />
9'-2"<br />
GARAGE DOOR<br />
8' X 6'-8"<br />
2'<br />
LAUNDRY<br />
9' CEILING<br />
STAIRS UP:<br />
6 1/2" RISE<br />
10" RUN<br />
(4 STEPS)<br />
14<br />
STAIRS UP:<br />
7 3/4" RISE<br />
10" RUN<br />
(16 STEPS)<br />
13<br />
D W<br />
3<br />
2<br />
1<br />
LANDING<br />
LANDING<br />
23<br />
FOYER<br />
9' PLT.HGT.<br />
4/12 SLOPE<br />
5'-0" FIX ARCHED<br />
TRANSOM ABOVE<br />
3' X 6'-8"<br />
1068 FIX 1068 FIX<br />
ENTRY PORCH<br />
VOLUM SEILING<br />
12'-4" PLT. HT.<br />
6/12 SLOPE<br />
6'-1" 6" 4" 6"<br />
UP<br />
8<br />
STAIRS UP:<br />
6 1/2" RISE<br />
10" RUN<br />
(3 STEPS)<br />
14'-8"<br />
23<br />
18'-7"<br />
4' X 4'<br />
XO<br />
W/ 20" FIX<br />
TRANSOM<br />
ABOVE<br />
LIVING ROOM<br />
VOLUME CEILING<br />
9' PLT.HGT.<br />
4' X 4'<br />
XO<br />
W/ 20" FIX<br />
TRANSOM<br />
ABOVE<br />
2'-8"<br />
1'-9"<br />
1-1<br />
A-6<br />
1. WINDOWS AND DOORS NOTED IN FEET (I.E. 3040=3'-0"X4'-0").<br />
2. DOORS ARE NOTED WITHOUT FRAME. CONTRACTOR TO VERIFY WITH MANUFACTURER FOR DOOR<br />
FRAME SIZE PRIOIR TO FRAMING DOOR OPENINGS.<br />
3. DO NOT SCALE OFF PLANS.<br />
4. ALL DIMENSIONS ARE TO FACE OF STUD. U.N.O.<br />
5. WALL INSULATION TO BE A MINIMUM OF R-13 BATTING AND ATTIC INSULATION TO BE R-38 BLOWN IN,<br />
BATT OR RIGID<br />
6. ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF THE<br />
CONTRACTOR AND THE SUB-CONTRACTORS. NOTED DIMENSIONS TAKE PRECEDENT OVER SCALE.<br />
EACH CONTRACTOR OR SUB-CONTRACTOR SHALL REPORT TO ARCHITECT/DESIGNER ALL<br />
CONDITIONS WHICH PREVENT THE PROPER EXECUTION OF THEIR WORK.<br />
7. DESIGNER TO BE NOTIFIED IMMEDIATELY BY CONTRACTOR OR SUB-CONTRACTOR SHOULD ANY<br />
DISCREPANCY OR OTHER QUESTION ARISE PERTAINING TO THE WORKING DRAWINGS AND/OR<br />
SPECIFICATIONS. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY<br />
ERRORS, DISCREPANCIES, OR OMISSIONS WHICH THE CONTRACTOR FAILED TO NOTIFY THE<br />
ARCHITECT/DESIGNER OF BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK.<br />
8. SUB-CONTRACTOR SHALL INSURE THAT ALL WORK IS DONE IN A PROFESSIONAL WORKMANLIKE<br />
MANNER BY SKILLED MECHANICS AND SHALL REPLACE ANY MATERIALS OR ITEMS DAMAGED BY SUB-<br />
CONTRACTORS PERFORMANCE. SUB-CONTRACTORS AND SUPPLIERS ARE HEREBY NOTIFIED THAT<br />
THEY ARE TO CONFER AND COOPERATE FULLY WITH EACH OTHER DURING THE COURSE OF<br />
CONSTRUCTION TO DETERMINE THE EXACT EXTENT AND OVERLAP OF EACH OTHER'S WORK AND TO<br />
SUCCESSFULLY COMPLETE THE EXECUTION OF THE WORK. ALL SUB-CONTRACTOR WORKMANSHIP<br />
WILL BE OF QUALITY TO PASS INSPECTIONS BY LOCAL AUTHORITIES, LENDING INSTITUTIONS,<br />
ARCHITECT/DESIGNER, OR BUILDER. ANY ONE OR ALL OF THE ABOVE MENTIONED INSPECTORS MAY<br />
INSPECT WORKMANSHIP AT ANY TIME, AND ANY CORRECTIONS NEEDED TO ENHANCE THE QUALITY<br />
OF BUILDING WILL BE DONE IMMEDIATELY. EACH SUB-CONTRACTOR,UNLESS SPECIFICALLY<br />
EXEMPTED BY THE TERMS OF HIS SUB-CONTRACT AGREEMENT, SHALL BE RESPONSIBLE FOR<br />
CLEANING UP AND REMOVING FROM THE JOB SITE ALL TRASH AND DEBRIS NOT LEFT BY OTHER SUB-<br />
CONTRACTORS. BUILDER WILL DETERMINE HOW SOON AFTER SUB-CONTRACTOR COMPLETES EACH<br />
PHASE OF HIS WORK THAT TRASH AND DEBRIS WILL BE REMOVED FROM THE SITE.<br />
9. 3" DEPRESSED SHOWER PAN. GLASS SHOWER ENCLOSURE TO START FROM FLOOR TILE. NO CURB.<br />
STAIRS:<br />
STAIRS TO COMPLY WITH 2016 CRC 311.7 STAIRS MUST BE 36" MIN. WIDE W/ TRIANGULAR OPENINGS SHALL<br />
NOT ALLOW A 6: SPHERE TO PASS THROUGH HANDRAILS TO BE 1.25"-2" GRIPABLE CROSS SECTION W/ NO<br />
SHARP CORNERS 34 - 38 INCHES ABOVE STAIR NOSING, EXTEND CONT. FROM TOP AND BOT. RISER AND END<br />
AT NEWEL POST OR RETURN TO WALL. HANDRAILS TO EXTEND 4 1/2" MAX. INTO REQUIRED STAIR WIDTH.<br />
LANDINGS TO BE MIN. 36" DEEP. STAIR NOSING TO BE MIN. 3/4" W/A 1 1/4" MAX. USE 5/8" TYPE 'X' GYP. BD. AT<br />
ALL WALLS AND CEILING UNDER STAIRS.<br />
42" MIN. HT. FOR RAILING, 1 1/2" CONT. GRIPABLE HANDRAIL RUNNING FULL LENGTH OF STAIR , 34" - 38"<br />
ABOVE STAIR NOSING, RAIL TO BE 1 1/2" CLR. FROM WALL<br />
UNDERFLOOR VENTING:<br />
(UNDERFLOOR AREA SHALL COMPLY WITH CRC R 408.1)<br />
UNDERFLOOR AREA: 1,433 SQ.FT.<br />
CALCULATION: (SQ.FT./150x144)<br />
REQUIRES THE USE OF A GLASS 1 VAPOR RETARTER<br />
REQUIRED AREA: 1,375 SQ.IN.<br />
TO BE PROVIDED BY: (13) X 105 SQ.IN. FOUNDATION VENTS<br />
TOPICAL VENTS BY 'PLYCO' (1-800-558-5895)<br />
4X14 -55 SQ.IN FREE VENTING<br />
6X14 -70 SQ.IN FREE VENTING<br />
8X14 -105 SQ.IN FREE VENTING<br />
6X14 LOUVERED -55 SQ.IN FREE VENTING<br />
NOTE:<br />
CONTRACTOR TO LOCATE VENTS EVENLY AROUND<br />
PERIMETER TO PROVIDE EVEN AIR FLOW TO ALL AREAS<br />
AND CORNERS OF UNDERFLOOR AREA. SUBSTITUTE<br />
MECHANICAL UNDERFLOOR VENTILATION WHERE<br />
PROPER UNDERFLOOR VENTILATION CAN NOT BE<br />
ACHIEVED WITH PERIMETER VENTS ALONE.<br />
FUNDATION VENT OPENINGS MUST BE COVERED<br />
WITH AN 1/8" CORROSION-RESISTANT WIRE MESH OR<br />
ONE OF THE OTNER OPTIONS LISTED IN CBC R408.2.<br />
1<br />
MARK<br />
ISSUE<br />
PROJECT NO:<br />
DATE<br />
CAD DWG FILE:<br />
DRAWN BY: VASIL BORODIN<br />
CHK'D BY:<br />
11/01/2018 ISSUED FOR REVIEW<br />
COPYRIGHT LEV DESIGNS<br />
SHEET TITLE:<br />
GRIPE<br />
RESIDENCE<br />
670 JEAN MARIE<br />
DR, SANTA ROSA<br />
DESCRIPTION<br />
FIRST FLOOR PLAN<br />
1'-6" 24'-11" 1'-6" 5'-7" 1'-4" 11'-7"<br />
9'-6" 12'-11" 5'-6"<br />
17<br />
WALL LEGEND :<br />
2"X4" STUDS @16" O.C.<br />
2"X6" STUDS @16" O.C.<br />
46'-5"<br />
CONCRET STOOP/LANDING<br />
FIRST FLOOR PLAN<br />
1/4" = 1'-0"<br />
A 3.0