5' X 4'<br />

XO<br />

HE<br />

S<br />

2'-6" X 6'-8"<br />

GFI<br />

+48"<br />

C<br />

GFI<br />

+48"<br />

GFI<br />

+48"<br />

XO TEMP OBS<br />

GFI<br />

4' X 1'<br />

UP<br />

XO<br />

5' X 4'<br />

S<br />

5' X 4'<br />

XO<br />

2'-4" X 6'-8"<br />

J<br />

220 V<br />

S<br />

GFI<br />

HE<br />

HE<br />

GFI<br />

2'-6" X 6'-8"<br />

RF<br />

3' X 4'<br />

FX<br />

S<br />

ELECTRICAL NOTES:<br />

1. IN ATTIC ABOVE:<br />

1.1PROVIDE DEDICATED CIRCUITS AT FURNACE . CEC422.12<br />

2.1 PROVIDE A LIGHT SWITCH & LIGHT FIXTURE<br />

2. PROVIDE BATHROOM OUTLET<br />

DEDICATED 20AMP CIRCUIT. CEC210.11(c)(2)<br />

3. LIGHT FIXTURES IN DAMP SPACES I .E. OVER THE TUB/SHOWER ARE TO BE SUITABLE<br />

FOR DAMP SPACES. PER CEC410.4(a)<br />

4. OUTLETS ARE REQUIRED WITHIN 24” OF ANY LOCATION ALONG THE COUNTERTOP.<br />

CEC210.52(C)(1)<br />

5. PROVIDE LAUNDRY OUTLET DEDICATED 20AMP CIRCUIT. CEC210.11(c)(2)<br />

6. A MINIMUM OF 2-20 AMP CIRCUITS SHALL SUPPLY ALL KITCHEN COUNTERTOP<br />

RECEPTACLES (TWO OR MORE 20-AMP SMALL APPLIANCE BRANCH CIRCUITS SHALL BE<br />

PROVIDED FOR ALL RECEPTACLE OUTLETS SPECIFIED BY 210.52(B). CEC201.11(C)(1)<br />

7. BATHROOM EXHAUST FANS MUST BE CONTROLLED BY A HUMIDISTAT CONTROL<br />

CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80%. 2016<br />

CGBSC SECTION 4.506<br />

8. THE BUILDER SHALL INSTALL A NOMINAL ONE (1) INCH INSIDE DIAMETER, LISTED<br />

RACEWAY TO ACCOMMODATE A DEDICATED A 208/240 VOLT BRANCH CIRCUIT . THE<br />

RACEWAY SHALL ORIGINATE IN THE MAIN OR SUB PANEL , AND WILL TERMINATE INTO A<br />

LISTED BOX AT THE PURPOSED SITE OF THE EV CHARGER. THIS AND ALL<br />

9. ADDITIONAL SPECIFICATIONS OF CALIFORNIA GREEN BUILDING STANDARDS SECTION<br />

4.106.4 SHALL BE MEET.<br />

10. PLEASE ADJUST THE ELECTRICAL LOAD CALCULATIONS TO ACCOMMODATE FOR A<br />

DEDICATED 40 AMP CIRCUIT FOR THE EV CHARGING CENTER. CGBS 4.106.4.1<br />

11. THE SERVICE OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCORRECT<br />

PROTECTION DEVICE SPACE(S) AS RESERVED FOR FUTURE EV CHARGING<br />

12. AS “EV CAPABLE. THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND<br />

VISIBLY MARKED AS “EV CAPABLE”<br />

13. LIGHT FIXTURES AT EXTERIOR TO BE LABELED “SUITABLE FOR DAMP LOCATION ” PER<br />

2016 CEC ART. 410.10 (A) & (D)<br />

14. LIGHT FIXTURES IN TUB OR SHOWER ENCLOSURES TO BE LABELED “SUITABLE FOR<br />

DAMP LOCATION” PER 2016 CEC ART. 410.10 (A) & (D)<br />

15. LIGHTING INSTALLED IN ATTACHED AND DETACHED GARAGES , LAUNDRY ROOMS AND<br />

UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINAIRES AND CONTROLLED BY VACANCY<br />

SENSORS. 2016 CAL-ENERGY CODE 150 (K).6<br />

16. PROVIDE ARC-FAULT CIRCUIT -INTERRUPTER PROTECTION TO ALL 120-VOLT, SINGLE<br />

PHASE, 15 AND 20-AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN<br />

DWELLINGS. (THROUGHOUT) 2016 CEC ART. 210.12 (B).<br />

17. PROVIDE TAMPER-RESISTANT RECEPTACLES IN THE DWELLING . ALL 125-VOLT, SINGLE<br />

PHASE, 15 AND 20-AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT<br />

RECEPTACLES. (THROUGHOUT) 2016 CEC ART. 406.12.<br />

18. PROVIDE TWO OR MORE 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS EVENLY<br />

PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM OR<br />

SIMILAR AREA TO SEVERE ALL WALL AND FLOOR RECEPTACLE OUTLETS . SUCH<br />

CIRCUITS SHALL HAVE NO OTHER OUTLETS PER 2016 CEC ART. 210.52<br />

19. ALL LIGHTING SHALL BE HIGH EFFICIENCY OR LED . BATHROOM LIGHTING SHALL BE HIGH<br />

EFFICIENCY AND CONTROLLED BY OCCUPANT SENSOR . HABITABLE ROOMS SHALL BE<br />

HIGH EFFICIENCY AND CONTROLLED BY A DIMMER . GARAGE, LAUNDRY ROOM, UTILITY<br />

ROOM AND CLOSETS SHALL BE HIGH EFFICIENCY.<br />

20. ALL EXTERIOR LIGHTING REQUIRES PHOTO CELL & MOTION SENSOR CONTROLS.<br />

KEYNOTE:<br />

1. CHANDELIER TO HANG FROM SECOND FLOOR.<br />

CEC SECTION 210.52 DWELLING UNIT RECEPTACLE OUTLETS:<br />

A. GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM , DINING ROOM, LIVING ROOM, PARLOR, LIBRARY,<br />

DEN, SUNROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF DWELLING UNITS,<br />

RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE GENERAL PROVISIONS SPECIFIED<br />

IN 210.52 (A)(1) THROUGH (A)(3).<br />

A.1.<br />

SPACING. RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY ALONG<br />

THE FLOOR LINE IN ANY WALL SPACE IS MORE THAT 1.8 (6FT) FROM A RECEPTACLE OUTLET .<br />

A.2. WALL SPACE . AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE FOLLOWING :<br />

A.2.A. ANY SPACE 600mm (2FT) OR MORE IN WIDTH (INCLUDING SPACE MEASURED AROUND CORNERS ) AND<br />

UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS, AND SIMILAR OPENINGS, FIREPLACES AND FIXED<br />

CABINETS.<br />

A.2.B. THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR WALLS , EXCLUDING SLIDING PANELS.<br />

A.2.C. THE SPACE AFFORDED BY FIXED ROOM DIVIDERS SUCH AS FREE STANDING BAR -TYPECOUNTERS OR<br />

RAILINGS<br />

A.3.<br />

FLOOR RECEPTACLES. RECEPTACLE OUTLETS IN FLOORS SHALL NOT BE COUNTED AS PART OF THE<br />

REQUIRED NUMBER OF RECEPTACLE OUTLETS UNLESS LOCATED WITHIN 450mm (18IN.) OF THE WALL.<br />

WHOLE HOUSE VENTILATION NOTES:<br />

ELECTRICAL<br />

MAIN PANEL<br />

HB<br />

WP/GFI<br />

GFI<br />

+48"<br />

HB<br />

WP<br />

PV<br />

MS<br />

HE<br />

OPT<br />

OPT<br />

OPT<br />

OPT<br />

HE<br />

6' X 6'-8"<br />

ELECTRICAL<br />

SUB PANEL<br />

2X4<br />

FLUORESCENT<br />

1<br />

2<br />

3<br />

HE<br />

HE<br />

STAIRS DOWN:<br />

6 1/2" RISE<br />

10" RUN<br />

(3 STEPS)<br />

OUTLET ABV.<br />

FOR GARAGE<br />

DOOR OPENER<br />

GARAGE<br />

DOOR<br />

MOTOR<br />

10' X 8' PD<br />

SD3<br />

S S V<br />

S2<br />

SD<br />

2'-6" X 6'-8"<br />

S<br />

2'-6" X 6'-8"<br />

SD<br />

SD<br />

SS V<br />

SSS<br />

SD<br />

3' X 6'-8"<br />

3' X 6'-8"<br />

OUTLET ABV.<br />

FOR GARAGE<br />

DOOR OPENER<br />

S<br />

GARAGE<br />

DOOR<br />

MOTOR<br />

WP<br />

PV<br />

MS<br />

S D3<br />

HE HE HE HE<br />

HE<br />

HE<br />

HE<br />

HE<br />

S<br />

HE<br />

HE<br />

HE<br />

S3<br />

HE<br />

HE<br />

CM<br />

HE<br />

HE<br />

HE<br />

HE<br />

S3<br />

DOWN<br />

HE<br />

STAIRS DOWN:<br />

6 1/2" RISE<br />

10" RUN<br />

(4 STEPS)<br />

GFI<br />

H<br />

C<br />

DW<br />

GFI<br />

GFI<br />

GFI<br />

OUTLET BLW<br />

FOR IGNITOR<br />

STAIRS UP:<br />

6" RISE<br />

12" RUN<br />

(18 STEPS)<br />

2X4<br />

FLUORESCENT<br />

HE<br />

HE<br />

XO<br />

5' X 4'<br />

D<br />

H<br />

C<br />

W<br />

220 V<br />

D<br />

GFI<br />

+48"<br />

HE<br />

HE<br />

DISPOSAL<br />

AIR SWITCH<br />

HALF HOT<br />

BLW FOR<br />

DISHWASHER<br />

S3 SD2S2<br />

WP<br />

PV<br />

MS<br />

GFI<br />

GFI/WP<br />

HE<br />

XO<br />

5' X 4'<br />

MW & OVEN<br />

OUTLET ABV<br />

FOR HOOD<br />

LANDING<br />

LANDING<br />

HE<br />

5' X 6'-8"<br />

UP<br />

GFI<br />

GFI<br />

B<br />

C<br />

GFI<br />

HE<br />

STAIRS UP:<br />

6 1/2" RISE<br />

10" RUN<br />

(3 STEPS)<br />

S2 S2 SD3 S2<br />

D2S<br />

S2<br />

1<br />

2<br />

3<br />

WP<br />

PV<br />

MS<br />

HE<br />

HE<br />

HE<br />

HE<br />

HE<br />

4' X 4'<br />

XO<br />

DOWN<br />

6' X 8' PD<br />

STAIRS DOWN:<br />

6 1/2" RISE<br />

10" RUN<br />

(3 STEPS)<br />

4' X 4'<br />

XO<br />

S<br />

HE<br />

HE<br />

HE<br />

HE<br />

WP<br />

PV<br />

MS<br />

HE<br />

HB<br />

C<br />

H<br />

HB<br />

S2<br />

SDS3<br />

VAC<br />

D<br />

B<br />

T<br />

P<br />

v<br />

V<br />

S<br />

J<br />

SD<br />

CM<br />

HE<br />

H<br />

D<br />

FL<br />

HE<br />

WP<br />

PV<br />

MS<br />

EMP SYMBOL LEGEND<br />

SWITCH<br />

3-WAY SWITCH<br />

DIMMER SWITCH<br />

4-WAY SWITCH<br />

COMBO JACK<br />

GAS STUB<br />

VACUUM PORT<br />

DISPOSAL<br />

DOORBELL<br />

THERMOSTAT<br />

PHOTOCELL SENSOR<br />

SHOWER HEAD<br />

COLD WATER STUB<br />

HOSE BIB W/ BACKFLOW PREVENTION DEVICE<br />

QUARTER HOT FOURPLEX RECEPTACLE<br />

SURFACE MOUNT LIGHT FIXTURE (CEILING)<br />

WALL MOUNT LIGHT FIXTURE<br />

WALL WASHER LIGHT FIXTURE (RECESSED)<br />

HIGH EFFICACY LIGHT FIXTURE (RECESSED)<br />

LED STRIP LIGHT<br />

FLUORESCENT LIGHT FIXTURE (SURFACE)<br />

SEE PLAN FOR SIZE<br />

INCANDESCENT LIGHT/FAN COMBINATION (RECESSED)<br />

FL FLUORESCENT LIGHT/FAN COMBINATION (RECESSED)<br />

FAN/LIGHT SIDE-BY-SIDE COMBINATION (RECESSED)<br />

GAS METER<br />

ELECTRICAL MAIN PANEL<br />

ELECTRICAL SUB PANEL<br />

PP<br />

VACANCY DETECTOR (CEILING)<br />

VACANCY DETECTOR (WALL)<br />

SPEAKER (CEILING)<br />

JUNCTION BOX 220V<br />

GARAGE DOOR SWITCH<br />

LIGHTED ADDRESS SIGN<br />

HOT WATER STUB<br />

SINGLE POLE RECEPTACLE<br />

FLUSH FLOOR DUPLEX RECEPTACLE<br />

DUPLEX RECEPTACLE<br />

1/2 HOT RECEPTACLE<br />

FOURPLEX RECEPTACLE<br />

220V RECEPTACLE<br />

STEP LIGHT (RECESSED)<br />

LIGHT FIXTURE (RECESSED)<br />

FAN<br />

DATA JACK<br />

PLUG AND PLAY OUTLET<br />

T.V. CABLE JACK<br />

(WALL)<br />

KEY VALVE (GAS)<br />

INTERCOM<br />

ELECTRIC VEHICLE POWER<br />

SUPPLY<br />

CHIMES<br />

SMOKE DETECTOR - HARD WIRED,<br />

INTERCONNECTED W/ BATTERY BACK -UP CRC R314<br />

CARBON MONOXIDE / SMOKE DETECTOR<br />

COMBO - HARD WIRED, INTERCONNECTED<br />

W/ BATTERY BACK UP CRC R315<br />

BATHROOM EXHAUST FAN W / HUMIDISTAT<br />

(CAL GREEN 4.506.1)<br />

C<br />

S<br />

WHOLE BUILDING VENTILATION FAN - SEE<br />

CFM REQ. (CENC 150 (o) & CAL GREEN 4.506.1)<br />

DIMMABLE<br />

FLUORESCENT<br />

HIGH EFFICACY<br />

WATERPROOF<br />

PHOTOVOLTAIC SENSOR<br />

MOTION SENSOR<br />

CEILING FAN<br />

SEE PLAN FOR SIZE<br />

1<br />

GRIPE<br />

RESIDENCE<br />

670 JEAN MARIE<br />

DR, SANTA ROSA<br />

11/01/2018 ISSUED FOR REVIEW<br />

IN LAUNDRY PROVIDE A 150CPM CONTINUOUS RATED INDOOR AIR QUALITY FAN PER CEC AND ENERGY<br />

CALCULATIONS (PANOSONIC FV-15VQ5 OR SIMILAR)<br />

GAS METER<br />

MARK<br />

ISSUE<br />

DATE<br />

DESCRIPTION<br />

SPECIFICATIONS:<br />

DUCT DIA. 6"<br />

-0.3 SONES AT 150 CFM<br />

-13" GRILL SIZE<br />

(PROVIDE LABEL AT SWITCH PER CA ENERGY STANDARDS SECTION 150.0<br />

DEDICATED<br />

FOR<br />

IRRIGATION<br />

GFI<br />

+48"<br />

2X4<br />

FLUORESCENT<br />

2X4<br />

FLUORESCENT<br />

HB<br />

PROJECT NO:<br />

CAD DWG FILE:<br />

DRAWN BY: VASIL BORODIN<br />

CHK'D BY:<br />

COPYRIGHT LEV DESIGNS<br />

GARAGE DOOR<br />

GARAGE DOOR<br />

SHEET TITLE:<br />

16' X 6'-8"<br />

HE<br />

8' X 6'-8"<br />

FIRST LEVEL ELECTRICAL PLAN<br />

HE<br />

WP<br />

PV<br />

MS<br />

WP<br />

PV<br />

MS<br />

HE<br />

WP<br />

PV<br />

MS<br />

FIRST LEVEL ELECTRICAL PLAN<br />

1/4" = 1'-0"<br />

E 1.0