ELECTRICAL NOTES:<br />
1. IN ATTIC ABOVE:<br />
1.1PROVIDE DEDICATED CIRCUITS AT FURNACE . CEC422.12<br />
2.1 PROVIDE A LIGHT SWITCH & LIGHT FIXTURE<br />
2. PROVIDE BATHROOM OUTLET<br />
DEDICATED 20AMP CIRCUIT. CEC210.11(c)(2)<br />
3. LIGHT FIXTURES IN DAMP SPACES I .E. OVER THE TUB/SHOWER ARE TO BE SUITABLE<br />
FOR DAMP SPACES. PER CEC410.4(a)<br />
4. OUTLETS ARE REQUIRED WITHIN 24” OF ANY LOCATION ALONG THE COUNTERTOP.<br />
CEC210.52(C)(1)<br />
5. PROVIDE LAUNDRY OUTLET DEDICATED 20AMP CIRCUIT. CEC210.11(c)(2)<br />
6. A MINIMUM OF 2-20 AMP CIRCUITS SHALL SUPPLY ALL KITCHEN COUNTERTOP<br />
RECEPTACLES (TWO OR MORE 20-AMP SMALL APPLIANCE BRANCH CIRCUITS SHALL BE<br />
PROVIDED FOR ALL RECEPTACLE OUTLETS SPECIFIED BY 210.52(B). CEC201.11(C)(1)<br />
7. BATHROOM EXHAUST FANS MUST BE CONTROLLED BY A HUMIDISTAT CONTROL<br />
CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80%. 2016<br />
CGBSC SECTION 4.506<br />
8. THE BUILDER SHALL INSTALL A NOMINAL ONE (1) INCH INSIDE DIAMETER, LISTED<br />
RACEWAY TO ACCOMMODATE A DEDICATED A 208/240 VOLT BRANCH CIRCUIT . THE<br />
RACEWAY SHALL ORIGINATE IN THE MAIN OR SUB PANEL , AND WILL TERMINATE INTO A<br />
LISTED BOX AT THE PURPOSED SITE OF THE EV CHARGER. THIS AND ALL<br />
9. ADDITIONAL SPECIFICATIONS OF CALIFORNIA GREEN BUILDING STANDARDS SECTION<br />
4.106.4 SHALL BE MEET.<br />
10. PLEASE ADJUST THE ELECTRICAL LOAD CALCULATIONS TO ACCOMMODATE FOR A<br />
DEDICATED 40 AMP CIRCUIT FOR THE EV CHARGING CENTER. CGBS 4.106.4.1<br />
11. THE SERVICE OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCORRECT<br />
PROTECTION DEVICE SPACE(S) AS RESERVED FOR FUTURE EV CHARGING<br />
12. AS “EV CAPABLE. THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND<br />
VISIBLY MARKED AS “EV CAPABLE”<br />
13. LIGHT FIXTURES AT EXTERIOR TO BE LABELED “SUITABLE FOR DAMP LOCATION ” PER<br />
2016 CEC ART. 410.10 (A) & (D)<br />
14. LIGHT FIXTURES IN TUB OR SHOWER ENCLOSURES TO BE LABELED “SUITABLE FOR<br />
DAMP LOCATION” PER 2016 CEC ART. 410.10 (A) & (D)<br />
15. LIGHTING INSTALLED IN ATTACHED AND DETACHED GARAGES , LAUNDRY ROOMS AND<br />
UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINAIRES AND CONTROLLED BY VACANCY<br />
SENSORS. 2016 CAL-ENERGY CODE 150 (K).6<br />
16. PROVIDE ARC-FAULT CIRCUIT -INTERRUPTER PROTECTION TO ALL 120-VOLT, SINGLE<br />
PHASE, 15 AND 20-AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN<br />
DWELLINGS. (THROUGHOUT) 2016 CEC ART. 210.12 (B).<br />
17. PROVIDE TAMPER-RESISTANT RECEPTACLES IN THE DWELLING . ALL 125-VOLT, SINGLE<br />
PHASE, 15 AND 20-AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT<br />
RECEPTACLES. (THROUGHOUT) 2016 CEC ART. 406.12.<br />
18. PROVIDE TWO OR MORE 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS EVENLY<br />
PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM OR<br />
SIMILAR AREA TO SEVERE ALL WALL AND FLOOR RECEPTACLE OUTLETS . SUCH<br />
CIRCUITS SHALL HAVE NO OTHER OUTLETS PER 2016 CEC ART. 210.52<br />
19. ALL LIGHTING SHALL BE HIGH EFFICIENCY OR LED . BATHROOM LIGHTING SHALL BE HIGH<br />
EFFICIENCY AND CONTROLLED BY OCCUPANT SENSOR . HABITABLE ROOMS SHALL BE<br />
HIGH EFFICIENCY AND CONTROLLED BY A DIMMER . GARAGE, LAUNDRY ROOM, UTILITY<br />
ROOM AND CLOSETS SHALL BE HIGH EFFICIENCY.<br />
20. ALL EXTERIOR LIGHTING REQUIRES PHOTO CELL & MOTION SENSOR CONTROLS.<br />
KEYNOTE:<br />
1. CHANDELIER TO HANG FROM SECOND FLOOR.<br />
CEC SECTION 210.52 DWELLING UNIT RECEPTACLE OUTLETS:<br />
A. GENERAL PROVISIONS. IN EVERY KITCHEN, FAMILY ROOM , DINING ROOM, LIVING ROOM, PARLOR, LIBRARY,<br />
DEN, SUNROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF DWELLING UNITS,<br />
RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE GENERAL PROVISIONS SPECIFIED<br />
IN 210.52 (A)(1) THROUGH (A)(3).<br />
A.1.<br />
SPACING. RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY ALONG<br />
THE FLOOR LINE IN ANY WALL SPACE IS MORE THAT 1.8 (6FT) FROM A RECEPTACLE OUTLET .<br />
A.2. WALL SPACE . AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE FOLLOWING :<br />
A.2.A. ANY SPACE 600mm (2FT) OR MORE IN WIDTH (INCLUDING SPACE MEASURED AROUND CORNERS ) AND<br />
UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS, AND SIMILAR OPENINGS, FIREPLACES AND FIXED<br />
CABINETS.<br />
A.2.B. THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR WALLS , EXCLUDING SLIDING PANELS.<br />
A.2.C. THE SPACE AFFORDED BY FIXED ROOM DIVIDERS SUCH AS FREE STANDING BAR -TYPECOUNTERS OR<br />
RAILINGS<br />
A.3.<br />
FLOOR RECEPTACLES. RECEPTACLE OUTLETS IN FLOORS SHALL NOT BE COUNTED AS PART OF THE<br />
REQUIRED NUMBER OF RECEPTACLE OUTLETS UNLESS LOCATED WITHIN 450mm (18IN.) OF THE WALL.<br />
WHOLE HOUSE VENTILATION NOTES:<br />
ELECTRICAL<br />
MAIN PANEL<br />
HB<br />
WP/GFI<br />
GFI<br />
+48"<br />
HB<br />
WP<br />
PV<br />
MS<br />
HE<br />
OPT<br />
OPT<br />
OPT<br />
OPT<br />
HE<br />
6' X 6'-8"<br />
ELECTRICAL<br />
SUB PANEL<br />
2X4<br />
FLUORESCENT<br />
1<br />
2<br />
3<br />
HE<br />
HE<br />
STAIRS DOWN:<br />
6 1/2" RISE<br />
10" RUN<br />
(3 STEPS)<br />
OUTLET ABV.<br />
FOR GARAGE<br />
DOOR OPENER<br />
GARAGE<br />
DOOR<br />
MOTOR<br />
10' X 8' PD<br />
SD3<br />
S S V<br />
S2<br />
SD<br />
2'-6" X 6'-8"<br />
S<br />
2'-6" X 6'-8"<br />
SD<br />
SD<br />
SS V<br />
SSS<br />
SD<br />
3' X 6'-8"<br />
3' X 6'-8"<br />
OUTLET ABV.<br />
FOR GARAGE<br />
DOOR OPENER<br />
S<br />
GARAGE<br />
DOOR<br />
MOTOR<br />
WP<br />
PV<br />
MS<br />
S D3<br />
HE HE HE HE<br />
HE<br />
HE<br />
HE<br />
HE<br />
S<br />
HE<br />
HE<br />
HE<br />
S3<br />
HE<br />
HE<br />
CM<br />
HE<br />
HE<br />
HE<br />
HE<br />
S3<br />
DOWN<br />
HE<br />
STAIRS DOWN:<br />
6 1/2" RISE<br />
10" RUN<br />
(4 STEPS)<br />
GFI<br />
H<br />
C<br />
DW<br />
GFI<br />
GFI<br />
GFI<br />
OUTLET BLW<br />
FOR IGNITOR<br />
STAIRS UP:<br />
6" RISE<br />
12" RUN<br />
(18 STEPS)<br />
2X4<br />
FLUORESCENT<br />
HE<br />
HE<br />
XO<br />
5' X 4'<br />
D<br />
H<br />
C<br />
W<br />
220 V<br />
D<br />
GFI<br />
+48"<br />
HE<br />
HE<br />
DISPOSAL<br />
AIR SWITCH<br />
HALF HOT<br />
BLW FOR<br />
DISHWASHER<br />
S3 SD2S2<br />
WP<br />
PV<br />
MS<br />
GFI<br />
GFI/WP<br />
HE<br />
XO<br />
5' X 4'<br />
MW & OVEN<br />
OUTLET ABV<br />
FOR HOOD<br />
LANDING<br />
LANDING<br />
HE<br />
5' X 6'-8"<br />
UP<br />
GFI<br />
GFI<br />
B<br />
C<br />
GFI<br />
HE<br />
STAIRS UP:<br />
6 1/2" RISE<br />
10" RUN<br />
(3 STEPS)<br />
S2 S2 SD3 S2<br />
D2S<br />
S2<br />
1<br />
2<br />
3<br />
WP<br />
PV<br />
MS<br />
HE<br />
HE<br />
HE<br />
HE<br />
HE<br />
4' X 4'<br />
XO<br />
DOWN<br />
6' X 8' PD<br />
STAIRS DOWN:<br />
6 1/2" RISE<br />
10" RUN<br />
(3 STEPS)<br />
4' X 4'<br />
XO<br />
S<br />
HE<br />
HE<br />
HE<br />
HE<br />
WP<br />
PV<br />
MS<br />
HE<br />
HB<br />
C<br />
H<br />
HB<br />
S2<br />
SDS3<br />
VAC<br />
D<br />
B<br />
T<br />
P<br />
v<br />
V<br />
S<br />
J<br />
SD<br />
CM<br />
HE<br />
H<br />
D<br />
FL<br />
HE<br />
WP<br />
PV<br />
MS<br />
EMP SYMBOL LEGEND<br />
SWITCH<br />
3-WAY SWITCH<br />
DIMMER SWITCH<br />
4-WAY SWITCH<br />
COMBO JACK<br />
GAS STUB<br />
VACUUM PORT<br />
DISPOSAL<br />
DOORBELL<br />
THERMOSTAT<br />
PHOTOCELL SENSOR<br />
SHOWER HEAD<br />
COLD WATER STUB<br />
HOSE BIB W/ BACKFLOW PREVENTION DEVICE<br />
QUARTER HOT FOURPLEX RECEPTACLE<br />
SURFACE MOUNT LIGHT FIXTURE (CEILING)<br />
WALL MOUNT LIGHT FIXTURE<br />
WALL WASHER LIGHT FIXTURE (RECESSED)<br />
HIGH EFFICACY LIGHT FIXTURE (RECESSED)<br />
LED STRIP LIGHT<br />
FLUORESCENT LIGHT FIXTURE (SURFACE)<br />
SEE PLAN FOR SIZE<br />
INCANDESCENT LIGHT/FAN COMBINATION (RECESSED)<br />
FL FLUORESCENT LIGHT/FAN COMBINATION (RECESSED)<br />
FAN/LIGHT SIDE-BY-SIDE COMBINATION (RECESSED)<br />
GAS METER<br />
ELECTRICAL MAIN PANEL<br />
ELECTRICAL SUB PANEL<br />
PP<br />
VACANCY DETECTOR (CEILING)<br />
VACANCY DETECTOR (WALL)<br />
SPEAKER (CEILING)<br />
JUNCTION BOX 220V<br />
GARAGE DOOR SWITCH<br />
LIGHTED ADDRESS SIGN<br />
HOT WATER STUB<br />
SINGLE POLE RECEPTACLE<br />
FLUSH FLOOR DUPLEX RECEPTACLE<br />
DUPLEX RECEPTACLE<br />
1/2 HOT RECEPTACLE<br />
FOURPLEX RECEPTACLE<br />
220V RECEPTACLE<br />
STEP LIGHT (RECESSED)<br />
LIGHT FIXTURE (RECESSED)<br />
FAN<br />
DATA JACK<br />
PLUG AND PLAY OUTLET<br />
T.V. CABLE JACK<br />
(WALL)<br />
KEY VALVE (GAS)<br />
INTERCOM<br />
ELECTRIC VEHICLE POWER<br />
SUPPLY<br />
CHIMES<br />
SMOKE DETECTOR - HARD WIRED,<br />
INTERCONNECTED W/ BATTERY BACK -UP CRC R314<br />
CARBON MONOXIDE / SMOKE DETECTOR<br />
COMBO - HARD WIRED, INTERCONNECTED<br />
W/ BATTERY BACK UP CRC R315<br />
BATHROOM EXHAUST FAN W / HUMIDISTAT<br />
(CAL GREEN 4.506.1)<br />
C<br />
S<br />
WHOLE BUILDING VENTILATION FAN - SEE<br />
CFM REQ. (CENC 150 (o) & CAL GREEN 4.506.1)<br />
DIMMABLE<br />
FLUORESCENT<br />
HIGH EFFICACY<br />
WATERPROOF<br />
PHOTOVOLTAIC SENSOR<br />
MOTION SENSOR<br />
CEILING FAN<br />
SEE PLAN FOR SIZE<br />
1<br />
GRIPE<br />
RESIDENCE<br />
670 JEAN MARIE<br />
DR, SANTA ROSA<br />
11/01/2018 ISSUED FOR REVIEW<br />
IN LAUNDRY PROVIDE A 150CPM CONTINUOUS RATED INDOOR AIR QUALITY FAN PER CEC AND ENERGY<br />
CALCULATIONS (PANOSONIC FV-15VQ5 OR SIMILAR)<br />
GAS METER<br />
MARK<br />
ISSUE<br />
DATE<br />
DESCRIPTION<br />
SPECIFICATIONS:<br />
DUCT DIA. 6"<br />
-0.3 SONES AT 150 CFM<br />
-13" GRILL SIZE<br />
(PROVIDE LABEL AT SWITCH PER CA ENERGY STANDARDS SECTION 150.0<br />
DEDICATED<br />
FOR<br />
IRRIGATION<br />
GFI<br />
+48"<br />
2X4<br />
FLUORESCENT<br />
2X4<br />
FLUORESCENT<br />
HB<br />
PROJECT NO:<br />
CAD DWG FILE:<br />
DRAWN BY: VASIL BORODIN<br />
CHK'D BY:<br />
COPYRIGHT LEV DESIGNS<br />
GARAGE DOOR<br />
GARAGE DOOR<br />
SHEET TITLE:<br />
16' X 6'-8"<br />
HE<br />
8' X 6'-8"<br />
FIRST LEVEL ELECTRICAL PLAN<br />
HE<br />
WP<br />
PV<br />
MS<br />
WP<br />
PV<br />
MS<br />
HE<br />
WP<br />
PV<br />
MS<br />
FIRST LEVEL ELECTRICAL PLAN<br />
1/4" = 1'-0"<br />
E 1.0