2' OVERHANG U.N.O<br />

6" OVERHANG U.N.O<br />

RIDGE<br />

1' OVERHANG U.N.O.<br />

F.A.U. UNIT<br />

F.A.U.<br />

PLATFORM<br />

1' OVERHANG U.N.O.<br />

RIDGE<br />

6"<br />

1' OVERHANG U.N.O<br />

2' OVERHANG U.N.O<br />

GENERAL ROOF NOTES:<br />

DS<br />

DS<br />

1. ROOF UNDERLAYMENT: PROVIDE ONE LAYER OF No. 30 ASPHALT FELT . UNDERLAYMENT SHALL BE APPLIED SHINGLE<br />

FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES FASTENED SUFFICIENTLY TO HOLD IN<br />

PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL .<br />

END LAPS SHALL BE OFFSET BY 6 FEET. CRC R905.2.7<br />

DS<br />

1' OVERHANG U.N.O.<br />

6:12<br />

1' OVERHANG U.N.O<br />

DS<br />

2. ATTIC VENTILATION : (NO EAVE VENTING ALLOWED PERCBC CHAPTER 7A) DORMER VENTS AND SIDE VENTS (WHERE<br />

OCCUR) SHALL PROVIDE A TOTAL VENTILATION AREA OF AT LEAST 1/150 OF THE ATTIC AREA INTO WHICH THEY OPEN .<br />

(CRC R806) THE VENT AREA MAY BE 1/300 PROVIDED THAT EITHER;<br />

- A VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF THE ATTIC INSULATION . (CES SECTION 110.8(j)) OR<br />

- AT LEAST 50% OF THE REQUIRED OPENING AREA IS WITH VENTS THAT ARE AT LEAST 3 FEET ABOVE THE LOW<br />

ROOF VENTS AND AT LEAST 50% OF THE REQUIRED VENT AREA IS PROVIDED WITH LOW VENTS (IE 50% HIGH AND<br />

50% AT EVE ) (CRC 904.1)<br />

- ATTIC HVAC VENTING (IF USED) 1 SQ. INCH OF VENT AREA SHALL BE PROVIDED FOR EACH 1000 BTU OF GAS FIRED<br />

HEATER CAPACITY . THESE VENTS SHALL BE LOCATED BOTH HIGH AND LOW IN THE ATTIC SPACE (WITHIN 12" OF THE<br />

LOW POINT AND 12" OF HIGH POINT)<br />

- BAFFLES REQURIED AT ATTIC VENTS BETWEEN RAFTERS OR TRUSS 'S FOR AIRFLOW OVER CEILING INSULATION.<br />

MAINTAIN 1" MIN CLEARANCE UNDER ROOF SHEATHING TO TOP OF BAFFLE<br />

- OPENINGS SHALL HAVE CORROSION RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1/8 INCH MINIMUM<br />

AND 1/4 INCH MAXIMUM OPENING.<br />

3. ATTIC ACCESS: PROVIDE ACCESS TO ALL SEPARATE ATTIC SPACES WITH MINIMUM CLEAR HEADROOM HEIGHTS OF 30".<br />

OPENINGS SHALL BE A MIN . OF 32"X32" WITH THE EXCEPTION OF ATTIC ACCESS SCUTTLE TO MECHANICAL EQUIPMENT<br />

LOCATED IN THE ATTIC. THIS SCUTTLE ACCESS SHALL BE SIZED TO ALLOW TO LARGEST PIECE OF THE FURNACE UNIT<br />

TO PASS THROUGH (CMC 904.1) AND NOT BE OVER 20'-0" FROM THE EQUIPMENT. (CMC 904.1-c) THE ATTIC ACCESS<br />

SHALL BE WEATHERSTRIPPED<br />

4. CONTRACTOR TO VERIFY LOCATION AND SIZE OF ALL ROOF OPENINGS AND EQUIPMENT PLATFORMS WITH A .C. CONTR.<br />

6:12<br />

6:12<br />

DS<br />

5. ROOFING CONTRACTOR SHALL PROVIDE A CERTIFICATE STATING THAT THE ROOFING HAS BEEN APPLIED PER<br />

MANUFACTURERS RECOMMENDATIONS.<br />

2' OVERHANG U.N.O.<br />

6. ALL ROOF FLASHING TO BE 26 GAUGE GALVANIZED IRON , COPPER OR ALUMINUM AND PAINTED TO MATCH ROOFING<br />

COLOR. UNO<br />

7. PROVIDE NEW ALUMINUM SEAMLESS GUTTER AND DOWNSPOUTS AS NECESSARY. (W/ SPLASHBLOCKS AS REQ.)<br />

8. SLOPING ROOF: (5 IN 12 PITCH MIN) TILE ROOF (10 LBS PER SF MAX) OVER #30 FELT MIN NEL LOCATIONS<br />

DS<br />

9. CONTRACTOR TO VERIFY TRUSS SIZES, ROOF SLOPE AND QUANTITY PRIOR TO<br />

FABRICATION.<br />

ATTIC VENTING REQ:<br />

DS<br />

2,487,5 SF<br />

1/300 = 8,3 SF REQ.<br />

8,3 SF REQ LOW + 7,3 SG HIGH<br />

PROVIDE:<br />

(12) 24" O'HAGIN (FLAME & FIRE) DORMER VENTS @ .8,4 SF EACH = 8,4 SF TOTAL<br />

(42) 3X2" DIAM.FRIEZE BLOCKS 0.10 SQ.FT. PER BLOCK<br />

2' OVERHANG U.N.O<br />

2' OVERHANG U.N.O<br />

6:12<br />

6:12<br />

O'HAGIN VENT (72 SQ. IN. FNVA) COMP<br />

ATTIC ACCESS , SEE PLAN FOR SIZE<br />

GRIPE<br />

RESIDENCE<br />

F.A.U. UNIT<br />

F.A.U. UNIT<br />

DS<br />

DS<br />

670 JEAN MARIE<br />

DR, SANTA ROSA<br />

6:12<br />

DS<br />

HIP<br />

6:12<br />

HIP<br />

DS<br />

DS<br />

DS<br />

DS<br />

6:12<br />

6:12<br />

2' OVERHANG U.N.O<br />

6:12<br />

2' OVERHANG U.N.O.<br />

1<br />

11/01/2018 ISSUED FOR REVIEW<br />

MARK<br />

DATE<br />

DESCRIPTION<br />

HIP<br />

HIP<br />

ISSUE<br />

PROJECT NO:<br />

CAD DWG FILE:<br />

DS<br />

DS<br />

DRAWN BY: VASIL BORODIN<br />

CHK'D BY:<br />

COPYRIGHT LEV DESIGNS<br />

DS<br />

DS<br />

SHEET TITLE:<br />

ROOF PLAN<br />

ROOF PLAN<br />

1/4" = 1'-0"<br />

A 5.0