E:Extension Terminal Functions<br />

Func NAME LCD Display Setting range Unit Min. Factory setting Change User remark<br />

No. Unit --22kW 30kW-- during op Set value<br />

E01 X1 terminal function E01 X1 FUNC 0 to 41 0 NA<br />

E02 X2 terminal function E02 X2 FUNC 1 NA<br />

E03 X3 terminal function E03 X3 FUNC 2 NA<br />

E04 X4 terminal function E04 X4 FUNC 3 NA<br />

E05 X5 terminal function E05 X5 FUNC - - 4 NA<br />

E06 X6 terminal function E06 X6 FUNC 5 NA<br />

E07 X7 terminal function E07 X7 FUNC 6 NA<br />

E08 X8 terminal function E08 X8 FUNC 7 NA<br />

E09 X9 terminal function E09 X9 FUNC 8 NA<br />

E10 Acceleration time 2 E10 ACC TIME2 0.01 to 3600s s 0.01 10.0 A<br />

E11 Deceleration time 2 E11 DEC TIME2 10.0 A<br />

E12 Acceleration time 3 E12 ACC TIME3 15.0 A<br />

E13 Deceleration time 3 E13 DEC TIME3 15.0 A<br />

E14 Acceleration time 4 E14 ACC TIME4 3.00 A<br />

E15 Deceleration time 4 E15 DEC TIME4 3.00 A<br />

E16 Torque limiter 2 (Driving)E16 DRV TRQ 2 20 to 200%, 999 % 1 999 A<br />

E17 (Braking) E17 BRK TRQ 2 A<br />

E20 Y1 terminal function E20 Y1 FUNC 0 to 39 0 NA<br />

E21 Y2 terminal function E21 Y2 FUNC 1 NA<br />

E22 Electronic thermal E22 Y3 FUNC - - 2 NA<br />

E23 overload relay E23 Y4 FUNC 7 NA<br />

E24 (<strong>for</strong> braking resistor) E24 Y5 FUNC 10 NA<br />

E25 Y5 RY operation mode E25 Y5RY MODE 0,1 - 1 0 NA<br />

E30 FAR function(Hysteresis) E30 FAR HYSTR 0.0 to 10.0Hz Hz 0.1 2.5 A<br />

E31 FDT function (Level) E31 FDT1 LEVEL 0.0 to 120.0Hz Hz 0.1 50.0 A<br />

E32 signal (Hysteresis) E32 FDT1 HYSTR 0.0 to 30.0Hz Hz 0.1 1.0 A<br />

E33 OL1function(Mode select) E33 OL1 WARNING0: Thermal calculation - - 0 A<br />

1: Output current<br />

E34 signal (Level) E34 OL1 LEVEL 5 to 200% A 0.01 Motor rated current A<br />

E35 (Timer) E35 OL1 TIMER 0.0 to 60.0s s 0.1 10.0 A<br />

E36 FDT2 function (Level) E36 FDT2 LEVEL 0.0 to 120.0Hz Hz 0.1 50.0 A<br />

E37 OL2 function (Level) E37 OL2 LEVEL 5 to 200% A 0.01 Motor rated current A<br />

E40 Display coefficient A E40 COEF A -999.00 to 999.00 - 0.01 0.01 A<br />

E41 Display coefficient B E41 COEF B -999.00 to 999.00 - 0.01 0.00 A<br />

E42 LED Display filter E42 DISPLAY FL 0.0 to 5.0s s 0.1 0.5 A<br />

E43 LED Monitor (Function) E43 LED MNTR 0 to 12 - - 0 A<br />

E44 (Display at STOP mode) E44 LED MNTR2 0, 1 - - 0 A<br />

E45 LCD Monitor(Function) E45 LCD MNTR 0, 1 - - 0 A<br />

E46 (Language) E46 LANGUAGE 0 to 5 - - 1 A<br />

E47 (Contrast) E47 CONTRAST 0(soft) to 10(hard) - - 5 A<br />

C:Control Functions of Frequency<br />

Func NAME LCD Display Setting range Unit Min. Factory setting Change User remark<br />

No. Unit --22kW 30kW-- during op Set value<br />

C01 Operation command C01 JUMP Hz 1 0.00 to 5.00 s 0.01 0.00 NA<br />

(FWD,REV) holding timer<br />

C02 Deceleration time (stopping)C02 JUMP Hz 2 0.00, 0.01 to 3600 s 0.01 0.00 NA<br />

C03 Short floor operation (freq.) C03 JUMP Hz 3 0.0 to 120.0 Hz 0.1 0.0 NA<br />

C04 (time) C04 JUMP HYSTR 0.00 to 10.00 s 0.01 0.00 NA<br />

C05 Multistep (Freq. 1) C05 MULTI Hz-1 0.00 to 120.00 Hz 0.01 0.00 A<br />

C06 frequency (Freq. 2) C06 MULTI Hz-2 0.00 A<br />

C07 setting (Freq. 3) C07 MULTI Hz-3 0.00 A<br />

C08 (Freq. 4) C08 MULTI Hz-4 0.00 A<br />

C09 (Freq. 5) C09 MULTI Hz-5 0.00 A<br />

C10 (Freq. 6) C10 MULTI Hz-6 0.00 A<br />

C11 (Freq. 7) C11 MULTI Hz-7 0.00 A<br />

C12 (Freq. 8) C12 MULTI Hz-8 0.00 A<br />

C13 Elevator (Speed) C13 MULTI Hz-9 1 to 500 m/min 1 60 NA<br />

C14 (Caunter weight) C14 MULTI Hz-10 0 to 65535 kg 1 0 NA<br />

C15 (Motor and Machine inertia) C15 MULTI Hz-11 0.00 to 500.00 kgm2 0.01 0.00 NA<br />

C16 (Inertia gain) C16 MULTI Hz-12 0 to 1000 % 1 100 NA<br />

C17 (Roping select) C17 MULTI Hz-13 0 to 2 - 1 0 NA<br />

C18 (Gear raito 1) C18 MULTI Hz-14 1 to 100 - 1 1 NA<br />

C19 (Gear raito 2) C19 MULTI Hz-15 NA<br />

C20 JOG frequency C20 JOG Hz 0.00 to 120.00 Hz 0.01 5.00 A<br />

9 SI27-3762b


A:Alternative Motor Parameters<br />

Func NAME LCD Display Setting range Unit Min. Factory setting Change User remark<br />

No. Unit --22kW 30kW-- during op Set value<br />

A01 Unused A01 MAX Hz-2 Data protection<br />

A02 A02 BASE Hz-2<br />

A03 A03 RATED V-2<br />

A04 A04 MAX V-2<br />

A05 A05 TRQ BOOST2<br />

A06 A06 ELCTRN OL2<br />

A07 A07 OL LEVEL2<br />

A08 A08 TIME CNST2<br />

A09 A09 TRQVECTOR<br />

2<br />

A10 A10 M2 POLES<br />

A11 A11 M2-CAP<br />

A12 A12 M2-Ir<br />

A13 A13 M2 TUN1<br />

A14 A14 M2 TUN2<br />

A15 A15 M2-Io<br />

A16 A16 M2-%R1<br />

A17 A17 M2-%X<br />

A18 A18 SLIP COMP2<br />

O:Option Parameters <strong>for</strong> Elevator<br />

Func NAME LCD Display Setting range Unit Min. Factory setting Change User remark<br />

No. Unit --22kW 30kW-- during op Set value<br />

o01 Speed control select o01 OPTION 01 0 to 1 - - 0 NA<br />

o02 Frequency (Speed) set filter o02 OPTION 02 0.000 to 5.000 s 0.001 0.000 A<br />

o03 PG pulse count o03 OPTION 03 360 to 8000 p 1 1024 NA<br />

o04 ASR(High freq.) (P gain) o04 OPTION 04 0.01 to 200.00 - 0.01 10.00 A<br />

o05 (I gain) o05 OPTION 05 0.000 to 5.000 s 0.001 0.100 A<br />

o06 Speed detection filter o06 OPTION 06 0.000 to 5.000 s 0.001 0.005 A<br />

o07 Torque command filter o07 OPTION 07 0.000 to 0.100 s 0.001 0.000 A<br />

o08 Observer (Select) o08 OPTION 08 0 to 2 - - 0 NA<br />

o09 (Gain) o09 OPTION 09 0.00 to 1.00 - 0.01 0.00 A<br />

o10 (Integral time) o10 OPTION 10 0.005 to 1.000 s 0.001 0.100 A<br />

o11 (Load inertia) o11 OPTION 11 0.01 to 500.00 kgm2 0.01 0.01 A<br />

o12 ASR FF gain o12 OPTION 12 0.000 to 10.000 s 0.001 0.000 A<br />

o13 Start method selection o13 OPTION 13 0 to 1 - - 0 NA<br />

o14 Start condition selection o14 OPTION 14 0 to 2 - - 0 NA<br />

o15 Stop frequency 1 o15 OPTION 15 0.0 to 10.0s s 0.1 0.0 NA<br />

(Holding time)<br />

o16 Multi-step frequency selection o16 OPTION 16 0.000 to0.100s s 0.001 0.000 NA<br />

match timer<br />

o17 Slip compensation o17 OPTION 17 0.00 to 1.00 - 0.01 1.00 NA<br />

(Correction coefficient)<br />

o18 (Responsibility) o18 OPTION 18 0.00 to 10.00s s 0.01 0.12 A<br />

o19 Brake control o19 OPTION 19 0 to 3 - - 0 NA<br />

(Operation selection)<br />

o20 (Operation level) o20 OPTION 20 0 to 200% % 1 100 NA<br />

o21 (Operation time of turn ON) o21 OPTION 21 0.00 to 10.00s s 0.01 0.00 NA<br />

o22 (Operation time of turn OFF) o22 OPTION 22 0.00 to 100.00s s 0.01 0.00 NA<br />

o23 S-curve o23 OPTION 23 1 to 50% % 1 10 NA<br />

(1st S-curve area during acc.)<br />

o24 (2nd S-curve area during acc.) o24 OPTION 24<br />

o25 (1st S-curve area during dec.) o25 OPTION 25<br />

o26 (2nd S-curve area during dec.) o26 OPTION 26<br />

o27 (Operation selection at stop) o27 OPTION 27 0 ot 1 - - 0 NA<br />

o28 ASR (P gain) o28 OPTION 28 0.01 to 200.00 - 0.01 10.00 A<br />

o29 (Zero command) (I gain) o29 OPTION 29 0.000 to 5.000 s 0.001 0.100 A<br />

o30 ASR(Low freq.) (P gain) o30 OPTION 30 0.01 to 200.00 - 0.01 10.00 A<br />

o31 (I gain) o31 OPTION 31 0.000 to 5.000 s 0.001 0.100 A<br />

o32 ASR switching freq. (Low) o32 OPTION 32 0 to 120 Hz 1 5 NA<br />

o33 (High) o33 OPTION 33 0 to 120 Hz 1 10 NA<br />

11 SI27-3762b


O:Option Parameters <strong>for</strong> Elevator<br />

Func NAME LCD Display Setting range Unit Min. Factory setting Change User remark<br />

No. Unit --22kW 30kW-- during op Set value<br />

o34 MCcontrol (Start waiting time)o34 OPTION 34 0.00 to 10.00s s 0.01 0.00 NA<br />

o35 (OFF time) o35 OPTION 35 0.00 to 100.00s s 0.01 0.00 NA<br />

o36 Start time o36 OPTION 36 0.00 to 10.00s s 0.01 0.00 NA<br />

o37 Brake control o37 OPTION 37 0.00 to 10.00s s 0.01 0.00 NA<br />

(Operation check wait time)<br />

o38 Power supply open-phase o38 OPTION 38 0 to 2 - 1 0 NA<br />

detection<br />

o39 Acc/dec calculator select o39 OPTION 39 0 to 1 - - 0 NA<br />

o40 Droop operation (Braking) o40 OPTION 40 -9.9 to 0.0 Hz 0.1 0.0 A<br />

o41 RS485 protocol selection o41 OPTION 41 0 to 1 - - 0 NA<br />

o42 Current vibration control o42 OPTION 42 0 to 32767 - 1 819 A<br />

o43 Slip compensation control o43 OPTION 43 0.00 to 15.00 Hz 0.01 0.00 A<br />

(Braking)<br />

o44 Speed agreement o44 OPTION 44 0 to 50 % 1 10 A<br />

/PG abnormality(Detection width)<br />

o45 (Detection timer) o45 OPTION 45 0.0 to 10.0 s 0.1 0.5 A<br />

o46 PG abnormality error selection o46 OPTION 46 0 to 1 - - 1 NA<br />

o47 Di torque bias 1 o47 OPTION 47 -200% to 200% % 1 0 A<br />

o48 2 o48 OPTION 48 0 A<br />

o49 3 o49 OPTION 49 0 A<br />

o50 Torque bias (Driving side) o50 OPTION 50 0.0 to 200.0% % 0.1 100.0 A<br />

o51 Gain (Braking side) o51 OPTION 51 100.0 A<br />

o52 Torque bias startup timer o52 OPTION 52 0.00 to 1.00 s 0.01 0.20 A<br />

o53 Starting torque comp. (Select)o53 OPTION 53 0 to 1 - - 0 NA<br />

o54 (Calculation start pulse1) o54 OPTION 54 0 to 255 p 1 0 NA<br />

o55 (Calculation start pulse2) o55 OPTION 55 0 to 255 p 1 0 NA<br />

o56 (Pulse count) o56 OPTION 56 0 to 255 p 1 0 A<br />