und Filteraggregat - Kemper
und Filteraggregat - Kemper
und Filteraggregat - Kemper
Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.
YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.
A. Why Fume Extraction<br />
Solder material contains different quantities of lead, tin, sinc, arsenic, cadmium, antimony and<br />
colophonic or hydrazine fluxes, despending upon the alloy used. During the soldering process,<br />
the liquified material releases smoke, gases and aerosols. The air is contaminated to such an<br />
extent that in most cases the maximum concentrations allowed for substances such as cadmium<br />
are exceeded. In addition, the fluxes crate formaldehyde and hydrazine – two substances classified<br />
as carcinogenic. Breathing these harmful substances has a negative impact on the worker´s<br />
health. Therefore they must be removed from the air before they reach the worker´s<br />
breathing zone. The KEMPER – Purification System is specially designet for use at soldering<br />
workplaces. It extracts the harmful substances at their source, and contributes to a better and<br />
healthier work environment.<br />
B. Function<br />
The contamindated air is extracted by exhaust arms mounted to the work table or the wall, away<br />
from the worker´s breathing zone. Hose then transfer the air into the extraction and filter unit.<br />
Filtering is accomplished in three stages:<br />
1. The pre-filter removes coarse particles<br />
2. The particulate filter removes even the smallest particles, down to <strong>und</strong>er 0,1 micron<br />
in diameter (efficiency greater than 99,997 % DOP-Test)<br />
3. The activated charcoal filter adsorbs gases and odors<br />
Blowers then direct the air through an exhaust grid, which returns it to the workplace.<br />
The cleaned air can be returned directly to the workplace.<br />
However, in spite of the high efficieny, if you do not want to return the cleandes air to the<br />
workplace, it can be exhausted outside using an adapter and the respective hose.<br />
C. Safety Precautions<br />
Caution:<br />
When using electrical devices, the following basic safety measures must be followed<br />
to prevent shock, inury or fire.<br />
Read and follow these instruction before using the filter unit.<br />
• Keep this Installation and Operating Manual handy<br />
• Do not use the unit to extract easily flammable or explosive gases<br />
• Do not use the unit to extract crrosive substances<br />
• Do not expose the connecting cable to heat, oil or sharp edges<br />
• Make sure the unit stands stable and secure<br />
• Use only original equipment filters<br />
• Do not operate the unit without filter inserts<br />
• Contaminants in the extracted air will destroy the blower!<br />
• Always unplug unit before opening it<br />
• Never cover intake or exhaust openings<br />
• Protect the unit from dampness<br />
7