QVC-22 - Ruud Lighting Direct
QVC-22 - Ruud Lighting Direct
QVC-22 - Ruud Lighting Direct
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CENTER DIRECT MOUNT – 4" POLE<br />
<strong>22</strong>" (559 mm) SQUARE TUBE POST TOP LIGHT<br />
Housing<br />
Seamless,<br />
die-cast aluminum<br />
Finish color: bronze<br />
Capacitor<br />
Ignitor<br />
(Where required)<br />
Lampholder<br />
Ballast<br />
Patented<br />
Hinge<br />
Assembly<br />
Sag Lens<br />
Tempered glass<br />
Supporting Yoke<br />
Extruded aluminum<br />
Finish color: bronze<br />
1.5" (38 mm)<br />
Mounting Bolts<br />
SPEC # WATTAGE CATALOG #<br />
PULSE START METAL HALIDE<br />
250W PSMH <strong>QVC</strong>6925-(a)(b)<br />
300W PSMH <strong>QVC</strong>6930-(a)(b)<br />
320W PSMH <strong>QVC</strong>6932-(a)(b)<br />
350W PSMH <strong>QVC</strong>6935-(a)(b)<br />
400W PSMH <strong>QVC</strong>6940-(a)(b)<br />
450W PSMH <strong>QVC</strong>6945-(a)(b)<br />
750W PSMH <strong>QVC</strong>675-(a)(b)<br />
1000W PSMH <strong>QVC</strong>699-(a)(b)<br />
METAL HALIDE<br />
250W MH <strong>QVC</strong>492-(a)(b)<br />
400W MH <strong>QVC</strong>494-(a)(b)<br />
1000W MH <strong>QVC</strong>499-(a)(b)<br />
HIGH PRESSURE SODIUM<br />
250W HPS <strong>QVC</strong>592-(a)(b)<br />
400W HPS <strong>QVC</strong>594-(a)(b)<br />
Specify (a) Voltage & (b) Options.<br />
2-Level available – consult factory.<br />
Reduced envelope lamp; ED28 for 320 – 400W PSMH &<br />
400W MH; BT37 for 1000W PSMH & 1000W MH.<br />
GENERAL DESCRIPTION<br />
Post top luminaire for vertical HID lamp, totally<br />
enclosed. Supplied with Type V square optical<br />
system. Die-cast aluminum fixture housing is<br />
supported by a square extruded aluminum yoke<br />
bracket. Gasketed, cast aluminum box supplied<br />
on top of 750 and 1000W PSMH, 1000W MH,<br />
250 and 400W HPS fixtures for lamp clearance.<br />
Mounting base is designed to fit inside a<br />
4" square pole. Provided are four 5/16" steel<br />
screws that secure mounting to pole. Lens<br />
assembly consists of rigid aluminum frame<br />
and clear, sag tempered glass.<br />
+<br />
26.5" (673 mm)<br />
<strong>22</strong>" (559 mm)<br />
2.5"<br />
(64mm)<br />
4"<br />
(102 mm)<br />
L.C.<br />
0.75" (19 mm)<br />
9.3"<br />
(235 mm)<br />
31"<br />
(787 mm)<br />
Box.<br />
Gasketed cast<br />
aluminum supplied on<br />
certain wattages<br />
Reflector<br />
Spun and anodized<br />
aluminum<br />
Lamp (Included)<br />
Reflector V-Inserts (4)<br />
Prefinished diffuse aluminum<br />
Lens Frame<br />
Die-cast<br />
aluminum door<br />
frame secures<br />
lens; sealed<br />
with silicone gasket<br />
Finish color: black<br />
Center <strong>Direct</strong> Mount<br />
Finish color: bronze<br />
(a) VOLTAGE SUFFIX KEY<br />
M 120/208/240/277V (Standard)<br />
T 120/277/347V (Canada Only) (Standard)<br />
1 120V<br />
2 277V<br />
27 277V Reactor (PSMH Only)<br />
3 208V<br />
4 240V<br />
5 480V<br />
6 347V (Canada Only)<br />
For voltage availability outside the US and Canada, see Bulletin TD-9 or<br />
contact your <strong>Ruud</strong> <strong>Lighting</strong> authorized International Distributor.<br />
ELECTRICAL<br />
Fixture includes clear, mogul-base lamp.<br />
320 – 400W PSMH and 400W MH utilize the<br />
ED28 reduced envelope lamp. 1000W PSMH &<br />
MH utilize the BT37 reduced envelope lamp.<br />
Pulse-rated porcelain enclosed, 4kv (5kv for 750<br />
& 1000W PSMH) rated screw-shell-type<br />
lampholder with spring-loaded center contact.<br />
Lamp ignitor included where required. All ballast<br />
assemblies are high-power factor and use the<br />
following circuit type:<br />
Reactor (277V PSMH)<br />
250 – 450W PSMH<br />
CWA — Constant Wattage Autotransformer<br />
250 – 1000W PSMH; 250 – 1000W MH;<br />
250 – 450W HPS<br />
(b) OPTIONS (factory-installed)<br />
-(a)F Fusing<br />
-(a)P Button Photocell<br />
(N/A for 1000W w/120V; N/A for 480V)<br />
-1P External Photocell (for 1000W/120V)<br />
-5P External Photocell (for 480V)<br />
Q Quartz Standby<br />
(includes 100W quartz lamp)<br />
(N/A on 277V Reactor)<br />
Specify (a) Single Voltage — See Voltage Suffix Key<br />
9201 Washington Avenue Racine, Wisconsin 53406-3772 USA PHONE (262) 886-1900 FAX (262) 884-3309<br />
© <strong>Ruud</strong> <strong>Lighting</strong> Inc. Printed in USA www.ruudlighting.com 12/11/03<br />
<strong>QVC</strong>-<strong>22</strong><br />
SERIES<br />
FINISH<br />
Exclusive DeltaGuard ® finish features an E-coat<br />
epoxy primer with medium bronze ultra-durable<br />
powder topcoat, providing excellent resistance<br />
to corrosion, ultraviolet degradation and<br />
abrasion. The finish is covered by our sevenyear<br />
limited warranty.<br />
LABELS<br />
ANSI lamp wattage label supplied, visible during<br />
relamping. UL Listed in the US and Canada for<br />
wet locations and enclosure classified IP54 per<br />
IEC 529 and IEC 598.<br />
PATENTS<br />
US 4,689,729; D333,009
<strong>QVC</strong>-<strong>22</strong><br />
SERIES<br />
CENTER DIRECT MOUNT – 4" POLE<br />
<strong>22</strong>" (559 mm) SQUARE TUBE POST TOP LIGHT<br />
EPA RATING<br />
EPA for 250 & 400W MH = 3.50. EPA for 250 & 400W HPS and 1000W MH = 3.56.<br />
90°<br />
60°<br />
30°<br />
5000<br />
7500<br />
10000<br />
0°<br />
<strong>Lighting</strong> Sciences Inc.<br />
Certified Test Report No. LSI 11586<br />
Candlepower distribution curve of 400W MH<br />
Square Tube Post Top Light.<br />
90°<br />
20000<br />
30° 30°<br />
30000<br />
0°<br />
90°<br />
<strong>Lighting</strong> Sciences Inc.<br />
Certified Test Report No. LSI 11636<br />
Candlepower distribution curve of 1000W MH<br />
Square Tube Post Top Light.<br />
Pole-spacing Example Data<br />
120' 100' 80' 60' 40'<br />
120'<br />
20' 0' 20' 40' 60' 80' 100' 120'<br />
36.6<br />
100'<br />
30.5<br />
80'<br />
24.4<br />
60'<br />
.1<br />
.3<br />
18.3<br />
40'<br />
.5<br />
1<br />
12.2<br />
20'<br />
6.1<br />
0'<br />
0 m<br />
20'<br />
6.1<br />
40'<br />
12.2<br />
60'<br />
18.3<br />
80'<br />
24.4<br />
100'<br />
30.5<br />
120'<br />
36.6<br />
36.6 30.5 24.4 18.3 12.2 6.1 0 m 6.1 12.2 18.3 24.4 30.5 36.6<br />
100'<br />
80'<br />
60'<br />
40'<br />
20'<br />
0'<br />
20'<br />
40'<br />
60'<br />
80'<br />
Isofootcandle plot of 250W MH<br />
Square Tube Post Top Light at 25'<br />
(7.6 m) mounting height. (Plan view)<br />
120'100'<br />
80' 60' 40' 20' 0' 20' 40' 60' 80' 100' 120'<br />
120'<br />
36.6<br />
.1<br />
.3<br />
.5<br />
1<br />
3<br />
Isofootcandle plot of 250W HPS<br />
Square Tube Post Top Light at 25'<br />
(7.6 m) mounting height. (Plan view)<br />
120' 100' 80' 60' 40' 20' 0' 20' 40' 60' 80' 100' 120'<br />
120'<br />
36.6<br />
Isofootcandle plot of 400W MH<br />
Square Tube Post Top Light at 30'<br />
(9.1 m) mounting height. (Plan view)<br />
Isofootcandle plot of 400W HPS<br />
Square Tube Post Top Light at 30'<br />
(9.1m) mounting height. (Plan view)<br />
9201 Washington Avenue Racine, Wisconsin 53406-3772 USA PHONE (262) 886-1900 FAX (262) 884-3309<br />
© <strong>Ruud</strong> <strong>Lighting</strong> Inc. Printed in USA www.ruudlighting.com<br />
12/11/03<br />
30.5<br />
24.4<br />
18.3<br />
12.2<br />
6.1<br />
0 m<br />
6.1<br />
12.2<br />
18.3<br />
24.4<br />
100'<br />
30.5<br />
120'<br />
36.6<br />
36.6 30.5 24.4 18.3 12.2 6.1 0 m 6.1 12.2 18.3 24.4 30.5 36.6<br />
Isofootcandle plots show initial footcandles at grade. (Footcandles ÷ 0.0929 = Lux)<br />
100'<br />
30.5<br />
80'<br />
.1<br />
24.4<br />
.3<br />
60'<br />
.5<br />
18.3<br />
40'<br />
1<br />
12.2<br />
20'<br />
6.1<br />
3<br />
0'<br />
0 m<br />
20'<br />
6.1<br />
40'<br />
12.2<br />
60'<br />
18.3<br />
80'<br />
24.4<br />
100'<br />
30.5<br />
120' 36.6<br />
36.6 30.5 24.4 18.3 12.2 6.1 0 m 6.1 12.2 18.3 24.4 30.5 36.6<br />
120'100'<br />
80' 60' 40' 20' 0' 20' 40' 60' 80' 100' 120'<br />
120'<br />
36.6<br />
100'<br />
30.5<br />
80'<br />
.1<br />
24.4<br />
60'<br />
.3<br />
.5<br />
1<br />
18.3<br />
40'<br />
3<br />
12.2<br />
20'<br />
6.1<br />
0'<br />
0 m<br />
20'<br />
6.1<br />
40'<br />
12.2<br />
60'<br />
18.3<br />
80'<br />
24.4<br />
100'<br />
30.5<br />
120' 36.6<br />
36.6 30.5 24.4 18.3 12.2 6.1 0 m 6.1 12.2 18.3 24.4 30.5 36.6<br />
Test area is centered within a (16) pole layout.<br />
Max. Recommended Pole-spacing<br />
Average Initial Light Levels at Grade<br />
(Footcandles ÷ 0.0929 = Lux)<br />
Catalog # Lamp Type Lamp Lumens Pole Height X x Y Footcandles Lux<br />
QV*492-M 250W MH 21,000 25' (7.62 m) 115' (35.1 m) x 115' (35.1 m) 1.19 13<br />
30' (9.14 m) 135' (41.1 m) x 135' (41.1 m) 0.86 9<br />
QV*494-M 400W MH 36,000 30' (9.14 m) 135' (41.1 m) x 135' (41.1 m) 1.48 16<br />
35' (10.7 m) 160' (48.8 m) x 160' (48.8 m) 1.07 12<br />
QV*499-M 1000W MH 110,000 35' (10.7 m) 160' (48.8 m) x 160' (48.8 m) 3.24 35<br />
40' (12.2 m) 180' (54.9 m) x 180' (54.9 m) 2.54 27<br />
QV*592-M 250W HPS 28,500 25' (7.62 m) 115' (35.1 m) x 115' (35.1 m) 1.54 17<br />
30' (9.14 m) 135' (41.1 m) x 135' (41.1 m) 1.11 12<br />
QV*594-M 400W HPS 50,000 30' (9.14 m) 135' (41.1 m) x 135' (41.1 m) 1.95 21<br />
35' (10.7 m) 160' (48.8 m) x 160' (48.8 m) 1.41 15<br />
Y<br />
X<br />
TEST<br />
AREA