Smart Metering - Farnell
Smart Metering - Farnell
Smart Metering - Farnell
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Mftrs. Price Each<br />
List No.<br />
Plugs<br />
Wire Size Polarity Order Code 1+ 10+ 25+<br />
LC4-CP 10-1 4.0/6.0 10-12 AWG Positive 174-0213● 1.87 1.50 1.35<br />
LC4-CP 10-2 4.0/6.0<br />
Sockets<br />
10-12 AWG Negative 174-0214● 1.87 1.50 1.35<br />
LC4-CP 11-1 4.0/6.0 10-12 AWG Positive 174-0215● 1.90 1.53 1.38<br />
LC4-CP 11-2 4.0/6.0<br />
Crimp Tool<br />
10-12 AWG Negative 174-0216● 1.90 1.53 1.38<br />
LC4-CX CZK48 10-12 AWG 174-0224● 293.35 –– ––<br />
Field Attachable Photovoltaic Power<br />
Systems LC4 Series<br />
Plug<br />
• Can be assembled anywhere on-site<br />
• Convenient for smaller installations<br />
• Complements the wiring concept with preassembled,<br />
overmolded connectors<br />
• Quick and easy assembly<br />
@<br />
Socket<br />
Specifications:-<br />
Current Rating 35A (12 AWG) / 40A (10 AWG) Voltage Rating 1000VDC<br />
Contact Resistance 5mohm Housing Material TPU<br />
IP Rating IP67 Wire Size 10-12 AWG<br />
Operating Temp. -40°C to 90°C No. of Mating Cycles 50<br />
Mftrs. Price Each<br />
List No.<br />
Plugs<br />
Wire Size Polarity Order Code 1+ 10+ 25+<br />
LC4-CP 30-1 4.0/6.0 10-12 AWG Positive 174-0217● 1.82 1.45 1.32<br />
LC4-CP 30-2 4.0/6.0 10-12 AWG Negative<br />
Sockets<br />
174-0218● 1.82 1.51 1.47<br />
LC4-CP 31-1 4.0/6.0 10-12 AWG Positive 174-0219● 2.24 1.80 1.63<br />
LC4-CP 31-2 4.0/6.0 10-12 AWG Negative<br />
Crimp Tool<br />
174-0220● 2.24 1.80 1.63<br />
LC4-CX CZK48 10-12 AWG 174-0224● 293.35 –– ––<br />
Multifunction Meter<br />
• Single or 3 phase system<br />
• Fully programmable CT & VT ratios<br />
• Security code access for programming<br />
• Blue LED display<br />
• Input voltage range 28-570V<br />
• Replacement for M802 and M812 Series meters<br />
Bezel = 96 x 96 x 19, Panel cut-out = 92 x 92mm<br />
Parameters measured Phase Voltage (V), Phase to Neutral Voltage (V), Phase Current (I),<br />
Frequency (Hz), Active Power (W), Active Energy (kWh),<br />
Reactive Power (VAr), Apparent Power (VA), Reactive Energy (VArh),<br />
Power Factor (PF), Instantaneous Amp Demand, Instantaneous Watt Demand,<br />
Instantaneous VA Demand, Maximum Amp Demand, Maximum Watt Demand,<br />
Maximum VA Demand, Neutral Current Measurement<br />
Mftrs. Price Each<br />
Type List No. Order Code 1+ 5+<br />
Standard<br />
Plug-In Options<br />
M850-MP1 175-8713● 99.00 80.00<br />
RS485 RS485-M850 175-8714● 35.00 28.00<br />
Pulse PULSE-M850 175-8715● 18.00 13.50<br />
08447 11 11 22<br />
• Rugged and durable for permanently reliable<br />
system operation<br />
• With contact-voltage protection<br />
• UV and ozone-resistant<br />
• Halogen-free<br />
FREE technical support<br />
Our trained engineers are here to help!<br />
techsales@farnell.co.uk<br />
Live technical chat at<br />
www.farnell.co.uk<br />
3 Phase Current Transformers<br />
• Moulded case current transformers<br />
• Input ranges from 100A to 250A<br />
• Secondary outputs 5A<br />
• For conductors up to 25mm<br />
• Foot mounted<br />
• Rated system voltage 0.72/3kV<br />
Order Code Mftrs. List No. Primary Current VA Class<br />
175-8716 CT105F-100/5-2.5/1 100A 2.5 1<br />
175-8717 CT105F-125/5-2.5/1 125A 2.5 1<br />
175-8719 CT105F-150/5-2.5/1 150A 2.5 1<br />
175-8721 CT105F-200/5-2.5/1 200A 2.5 1<br />
175-8722 CT105F-250/5-2.5/1 250A 2.5 1<br />
Ratio Price Each<br />
Input/Output Order Code 1+ 5+ 10+<br />
100A/5A 175-8716● 25.00 23.81 22.05<br />
125A/5A 175-8717● 25.50 24.29 22.50<br />
150A/5A 175-8719● 26.00 24.76 22.94<br />
200A/5A 175-8721● 26.50 25.24 23.38<br />
250A/5A 175-8722● 27.00 25.71 23.80<br />
3 1 ⁄2 Digit - LED Voltmeter<br />
• Daylight-readable LED display with automatic brightness adjustment<br />
• Operates from universal 85-264Vac or 110-300Vdc<br />
• Input circuit fully isolated from operating ac power source<br />
• Red LED backlighting<br />
Supply Voltage 85 to 264Vac Rated Voltage 300Vac<br />
Supply Current: Sampling Rate 2.5 readings per second<br />
Total Darkness 4mA Accuracy ±0.4%FS ± 2 counts<br />
Full Sunlight 40mA Operating Temperature -25°C to 60°C<br />
Input Range<br />
DMU-30ACV Series<br />
Order Code 1+ 5+<br />
Price Each<br />
10+ 25+ 50+<br />
0 to 19.33 169-2063● 89.98 85.50 77.50 76.00 74.99<br />
0 to 199.9 169-2064● 89.98 85.50 77.50 76.00 74.99<br />
0 to 300<br />
DMU-30DCV Series<br />
169-2065● 89.98 85.50 77.50 76.00 74.99<br />
0 to ±1.999 169-2066● 84.68 79.50 72.50 71.75 70.45<br />
0 to ±19.99 169-2067● 84.68 79.50 72.50 71.75 70.45<br />
0 to ±199.9 169-2068● 84.68 79.50 72.50 71.75 70.45<br />
10A to 82.5A DIN Rail & Surface Mount<br />
HS Series<br />
• Continuous current 1.2 x rated current<br />
• Ambient temperature range -30°C to +80°C<br />
• Conforms to IEC185, BS 7626, BSEN<br />
60044-1 and IEC 60044-1.<br />
• CE Marked<br />
• Combined AC output ratings from<br />
5 to 80 amps rms @ 40°C<br />
• 24 to 280 & 48 to 660 VAC 50/60<br />
Hz AC line rated SSRs available<br />
• Single, dual and 3 channel output models available<br />
• AC or DC control models available<br />
• Ready to use, no assembly required<br />
Fax: 08447 11 11 12 08447 11 11 11 www.farnell.co.uk 55<br />
Connectors | Electromechanical