<strong>Adabas</strong> <strong>Console</strong> <strong>Messages</strong> (ADAN* & ADACM*)<br />
ADAN46 Function not executable<br />
16<br />
Explanation The requested function/command was valid but could not be executed. This message<br />
may occur alone or preceded by one of the following ADAN46 messages, which<br />
provide reasons why the current nucleus status does not allow the requested function:<br />
ADAN46<br />
Message<br />
Text<br />
Online<br />
process<br />
running<br />
Not yet<br />
supported by<br />
Cluster<br />
Services<br />
Failed to<br />
acquire<br />
global<br />
parameter<br />
lock<br />
Explanation Action<br />
The ADAEND request was rejected<br />
because an online reorder or online<br />
invert process is running.<br />
The version of <strong>Adabas</strong> Cluster<br />
Services you are running does not<br />
support the requested function. The<br />
function is supported only by a<br />
nucleus running in noncluster mode.<br />
An error occurred when a nucleus<br />
running in <strong>Adabas</strong> cluster mode<br />
attempted to acquire the global<br />
parameter lock in order to change a<br />
global <strong>Adabas</strong> parameter. The<br />
parameter was not changed.<br />
Request ADAEND again after<br />
the online process finishes.<br />
Consider using HALT to stop<br />
the online process and shut<br />
down the nucleus.<br />
Contact your <strong>Software</strong> <strong>AG</strong><br />
technical support<br />
representative.<br />
In addition, if User Exit 2 is attempting to switch from one dual log to another and if the<br />
data set to be overwritten is full, this error will be issued.<br />
Action Wait a minute or two, then retry the command. If the message recurs, advise your<br />
system support personnel. If the message recurs while trying to issue a command in<br />
response to a previous error, make a note of that error and the related information for<br />
future reference.<br />
ADAN47 Online DUMP-DB is running, function not executed<br />
Explanation A SYNCC, ADAEND, HALT, or CANCEL operator command was issued, but is not<br />
permitted during the current online save operation.<br />
Action Wait until the online save has ended, then retry the command.<br />